manualshive.com logo in svg
background image

Advanced Industrial Automation

»  

Pe r fe c t   c o n t ro l

»  

E n h a n c e d   f u n c t i o n a l i ty 

»  

Easy  setting  up 

E5CSV temperature controller

R e a d y,   s e t ,   g o ! 

Содержание E5CSV -

Страница 1: ...Advanced Industrial Automation Perfect control Enhanced functionality Easy setting up E5CSV temperature controller Ready set g o ...

Страница 2: ...mperature control in 4 simple steps The E5CSV temperature controller series is the enhanced successor to our E5CS series the most widely sold temperature controller that has established itself throughout the world as the ideal choice for simple cost effective temperature control P SV protection SW1 ON OFF PID control SW2 fast or slow process SW3 Heat or Cool SW4 Input shift ON OFF SW5 Thermocouple...

Страница 3: ...e control requirements with only 4 models No expert knowledge needed to optimise performance because of Self and Auto Tuning functions Reduced chance of malfunction thanks to set value protection End user friendly since the menu only has 3 parameters Excellent legibility with a large 13 5 mm single line 3 5 digit 7 segment LED display Clear status overview thanks to PV SV deviation indicator outpu...

Страница 4: ...er of alarms 1 1 alarm 3 Input type T Thermocouple platinum resistance thermometer multi input 4 Power supply voltage Blank 100 to 240 VAC D 24 VAC VDC 5 Terminal cover 500 Finger protection cover Ordering Information List of Models Accessories Order Separately Protective Front Cover 1 2 3 4 5 E5CSV 1T 500 Size Power supply voltage Number of alarm points Control output TC Pt multi input Incl termi...

Страница 5: ...uence of voltage Hysteresis for ON OFF control 0 1 FS Proportional band P 1 to 999 C automatic adjustment using auto tuning self tuning Integral time I 1 to 1 999 s automatic adjustment using auto tuning self tuning Derivative time D 1 to 1 999 s automatic adjustment using auto tuning self tuning Alarm output range Absolute value alarm Same as the control range Other 0 to 100 FS Alarm hysteresis 0...

Страница 6: ...ause measurement errors 2 Models with 100 to 240 VAC and 24 VAC VDC are separate Models using 24 VDC have no polarity Panel Cutout Dimensions 44 8 44 8 84 78 6 48 48 60 min L 48 N 2 5 1 0 Mounting side by side group mounting of N Controllers 45 0 6 0 45 0 6 0 45 0 6 0 L Tightening screws 48 76 5 7 5 Adapter for flush mounting Panel Y92F 30 Adapter for flush mounting 58 E5CSV Note 1 The recommended...

Страница 7: ...d The ALM indicator lights when the alarm value 1 is being displayed PV SP Alarm Value Input Shift Display Alarm indicators ALM1 Alarm 1 Lights when the alarm 1 output is ON ALM2 Alarm 2 For future use Up Key Pressing the Up Key increases the SP alarm value display Keeping the Up Key pressed continues to increase the display value When the internal protect switch is ON press the Up Key while holdi...

Страница 8: ...100 0 100 1 700 1 300 1 300 850 850 400 400 199 9 199 9 199 9 0 0 0 0 0 0 0 99 99 99 99 99 99 Setting number 0 1 2 3 4 5 6 7 8 9 Input Pt100 JPt100 SP range 1 000 900 800 700 600 500 400 300 200 100 0 100 850 500 400 400 199 9 200 199 9 200 99 99 0 0 0 0 0 0 0 0 99 99 99 99 Setting number 0 1 2 3 4 5 6 7 8 9 Mode Key Display Order If the SP falls outside the temperature range when the temperature ...

Страница 9: ... ON OFF PID PID control ON ON OFF control OFF Control period 2 s ON 20 s OFF Direct reverse opera tion Direct operation cooling ON Reverse operation heating OFF Input shift display Enabled ON Disabled OFF Tempera ture Sensor selection Platinum resistance thermometer input ON Thermocouple input OFF Temper ature unit F ON C OFF 6 5 4 3 2 1 ON 6 5 4 3 2 1 ON Set value Alarm type Alarm output operatio...

Страница 10: ...or Switch 2 OFF control period 20 s Quick Control Response Using an SSR Switch 2 ON control period 2 s 2 Set direct reverse operation for the output Performing Heating Control for Heaters Switch 3 OFF Performing Cooling Control for Freezers Switch 3 ON 6 5 4 3 2 1 ON Switch 1 OFF ON OFF control OFF ON Control output SP 6 5 4 3 2 1 ON OFF ON Control output SP 6 5 4 3 2 1 ON Switch 1 ON PID control ...

Страница 11: ...input shift set the input shift value to h0 The shift range depends on the setting unit 5 Protect Switch When the protect switch is ON Up Key and Down Key operations are prohibited to prevent setting mistakes 6 5 4 3 2 1 ON Multi input Thermocouple Platinum Resistance Thermometer Control mode switch 5 OFF Multi input Thermocouple Platinum Resistance Thermometer Control mode switch 5 ON Set ting F ...

Страница 12: ...ystems Programmable logic controllers Human machine interfaces Remote I O Motion Drives Motion controllers Servo systems Inverters Control Components Temperature controllers Power supplies Timers Counters Programmable relays Digital panel indicators Electromechanical relays Monitoring products Solid state relays Limit switches Pushbutton switches Low voltage switch gear Sensing Safety Photoelectri...