Limit Controller

 

E5CN-FR

Precautions

Precautions for Safe Use

1.

Do not use this product in the following places:

Places directly subject to heat radiated from heating equipment.

Places subject to splashing liquid or oil atmosphere.

Places subject to direct sunlight.

Places subject to dust or corrosive gas (in particular, sulfide gas 
and ammonia gas).

Places subject to intense temperature change.

Places subject to icing and condensation.

Places subject to vibration and large shocks.

2.

Use and store within the rated temperature and humidity ranges. 
Provide forced-cooling if required.

3.

To allow heat to escape, do not block the area around the 
product. Do not block the ventilation holes on the product.

4.

Be sure to wire properly with correct polarity of terminals.

5.

Use specified size (M3.5, width 7.2 mm or less) crimped 
terminals for wiring. Use wires with a gage of AWG24 to AWG14 
(equal to cross-sectional areas of 0.205 to 2.081 mm

2

). (The 

stripping length is 5 to 6 mm.).

6.

Do not wire the terminals that are not used.

7.

Allow as much space as possible between the product and 
devices that generate a powerful high-frequency or surge. 
Separate the high-voltage or large-current power lines from other 
lines, and avoid parallel or common wiring with the power lines 
when you are wiring to the terminals.

8.

Use this product within the rated load and power supply. 

9.

Make sure that the rated voltage is attained within two seconds 
of turning the power ON.

10.

Make sure the product has 30 minutes or more for warm up.

11.

A switch or circuit breaker must be provided close to the product. 
The switch or circuit breaker must be within easy reach of the 
operator, and must be marked as a disconnecting means for this 
unit.

12.

Always turn OFF the power supply before pulling out the interior 
of the product, and never touch nor apply shock to the terminals 
or electronic components. When inserting the interior of the 
product, do not allow the electronic components to touch the 
case.

13.

Do not use paint thinner or similar chemical to clean with. Use 
standard grade alcohol. 

14.

Design the system (e.g., control panel) considering the 2 
seconds of delay that the product's output to be set after power 
ON.

15.

The output may turn OFF when shifting to certain levels. Take 
this into consideration when performing control.

16.

Refer to the instruction sheet for installing Option Unit (E53-
CN03N/E53-CNBN/E53-CNPBN).

Do not touch the terminals while power is being supplied.
Doing so may occasionally result in minor injury due to 
electric shock.

Do not allow pieces of metal, wire clippings, or fine 
metallic shavings or filings from installation to enter the 
product. Doing so may occasionally result in electric 
shock, fire, or malfunction.

Do not use the product where subject to flammable or 
explosive gas. Otherwise, minor injury from explosion 
may occasionally occur.

Never disassemble, modify, or repair the product or touch 
any of the internal parts. Minor electric shock, fire, or 
malfunction may occasionally occur.

Caution: Risk of Fire and Electric Shock
a) This product is UL listed as Open Type Process 

Control Equipment. It must be mounted in an 
enclosure that does not allow fire to escape externally.

b) More than one disconnect switch may be required to 

de-energize the equipment before servicing.

c) Signal inputs are SELV, limited energy.
d) Caution: To reduce the risk of fire or electric shock, do 

not interconnect the outputs of different Class 2 
circuits.

If the output relays are used past their rated load or life 
expectancy, contact fusing or burning may occasionally 
occur. Always consider the application conditions and the 
inrush current, and use the output relays within their rated 
load and electrical life expectancy. The life expectancy of 
output relays varies considerably with the output load and 
switching conditions.

Tighten the terminal screws to between 0.74 and 0.9 N·m. 
Loose screws may occasionally result in fire.

Set the parameters of the product so that they are 
suitable for the system. If they are not suitable, 
unexpected operation may occasionally result in property 
damage or accidents.

Warning: To reduce the risk of electric shock or fire, install 
in a Pollution Degree 2 environment (a controlled 
environment relatively free of contaminants).

A malfunction in the product may occasionally make 
control operations impossible or prevent alarm outputs, 
resulting in property damage to connected equipment 
and machinery. To maintain safety in the event of 
malfunction of the product, periodically check the Limit 
Controller's operation.

 

!

CAUTION

Содержание E5CN-FR

Страница 1: ...mit over continuation time and limit over max min value measuring functions New Annunciator Output Warning Function Hazard lights and buzzers on the devices alert the user of errors when limit over errors occur Reset Limit Outputs Using Event Inputs Models with Event Inputs Limit outputs can be reset using event inputs enabling multiple limit outputs to be reset altogether from a distance Input Er...

Страница 2: ...53 CN N Size Power supply voltage Number of alarm points Control outputs Model 1 16 DIN 48 48 78 W H D 100 to 240 VAC 0 Limit output E5CN FRMT 500 2 Limit output E5CN FR2MT 500 Functions Model Communications E53 CN03N Two event inputs E53 CNBN Two event inputs External power supply for ES1B E53 CNPBN This data sheet is provided as a guideline for selecting products Be sure to refer to the followin...

Страница 3: ...d individual indicators Character height PV 11 mm SV 6 5 mm Other functions Limit over continuation time measurement function Limit over max min value measurement function Annunciator output Input error output PV display two color switching function Input digital filter Input compensation Protection functions Ambient operating temperature 10 to 55 C with no icing or condensation for 3 year warrant...

Страница 4: ...upper limit for alarm 2 type Set value Alarm type Alarm output operation When X is positive When X is negative 0 Alarm function OFF Output OFF 1 See note 1 Upper and lower limit deviation See note 2 2 Upper limit deviation 3 Lower limit deviation 4 See note 1 Upper and lower limit range deviation See note 3 5 See note 1 Upper and lower limit with standby sequence deviation See note 5 See note 4 6 ...

Страница 5: ...Destruction 300 m s2 min 3 times each in X Y and Z directions Weight Controller Approx 150 g Mounting Bracket Approx 10 g Degree of protection Front panel NEMA4X for indoor use equivalent to IP66 Rear case IP20 Terminal section IP00 Memory protection Non volatile memory number of writes 1 000 000 operations EMC Emission Enclosure EN55011 Group1 ClassA Emission AC Mains EN55011 Group1 ClassA Immuni...

Страница 6: ...ote Alarm 2 Infrared temperature sensor Communications Platinum resistance thermometer Event input 1 Event input 2 Event inputs 6 7 8 9 10 11 12 13 14 15 1 3 2 4 5 11 12 13 14 15 B Pt TC A B B A 6 7 8 1 2 RS 485 11 12 13 14 15 Input power supply 100 to 240 VAC 11 12 13 14 15 Event input 1 Event input 2 Event inputs External power supply for ES1B 12 VDC 10 20 mA External power Note Output when an i...

Страница 7: ...in the specified mounting space between Controllers To mount the Controller so that it is waterproof insert the waterproof packing onto the Controller When two or more Controllers are mounted make sure that the surrounding temperature does not exceed the allowable operating temperature specified in the specifications Note The terminal block cannot be removed The suffix 500 is added to the model nu...

Страница 8: ...ctions shorts and input type See note 3 OFF Operates as above the upper limit lo Over lower limit indication range See note 2 Input value is smaller than control range Check the control range Upper limiter Normal operation Operates as above the lower limit Lower limiter OFF hi Over upper limit indication range See note 2 Input value is larger than control range Check the control range Upper limite...

Страница 9: ...Limit Controller E5CN FR 9 ...

Страница 10: ...lue 1 al1l F 0 M Alarm value 2 al 2 F 0 M Upper limit alarm value 2 al2h F 0 M Set either of these parameters Lower limit alarm value 2 al2l F 0 M Press the Level Key for less than 1 s Press the Level Key for less than 1 s Power ON sp s 100 M Limit over continuation time time M Limit over max value p hi F M Limit over min value p lo F Monitor only Press the Level Key for at least 3 s Press the Lev...

Страница 11: ...Alarm 2 type alt2 2 M Move to advanced function level amov 0 Advanced Function Setting Level Parameter initialization init off M Event input assignment 1 ev 1 none Standby sequence reset method rest a M Alarm 1 open in alarm al1n n o Alarm 1 hysteresis alh1 0 2 M Alarm 2 open in alarm al2n n o M M M Alarm 2 hysteresis alh2 0 2 M Input digital filter inf 0 0 Additional PV display pvad on Automatic ...

Страница 12: ...ey for 1 second min while in the operation level The limit output reset operation can be used to reset limit outputs and annunciator outputs When the limit status is OFF the limit output is cleared and the limit output relay turns ON When the limit status is ON limit over status limit outputs will not be reset The annunciator output turns OFF regardless of the limit status Event inputs used as res...

Страница 13: ...requiring a high degree of safety take into account all ratings performance capacities failsafe measures and other safety measures required by the application and consult with your OMRON representative to confirm specifications and capabilities Controlled device Furnace oven Sensor input Limit Sensor Temperature Sensor Heater Temperature Controller e g E5CN E5CN FR Limit Controller Limit output Co...

Страница 14: ...et after power ON 15 The output may turn OFF when shifting to certain levels Take this into consideration when performing control 16 Refer to the instruction sheet for installing Option Unit E53 CN03N E53 CNBN E53 CNPBN Do not touch the terminals while power is being supplied Doing so may occasionally result in minor injury due to electric shock Do not allow pieces of metal wire clippings or fine ...

Страница 15: ...t 2 Avoid using the Controller in places near a radio television set or wireless installing These devices can cause radio disturbances which adversely affect the performance of the Controller Mounting Mounting to a Panel 1 To mount the Controller so that it is waterproof insert the waterproof packing onto the Controller Group mounting does not allow waterproofing The waterproof packing is not requ...

Страница 16: ...ller Digital Temperature Controller E5CN E5CN U This Best selling General purpose 48 48 mm Temperature Controller Is Now Better USB Serial Conversion Cable and Support Software Are Also Available CatalogNumber H126 Infrared Thermosensor ES1B Achieve Low cost Measurements with an Infrared Thermosensor CatalogNumber H127 ...

Страница 17: ...Limit Controller E5CN FR 17 ...

Страница 18: ...18 Limit Controller E5CN FR ...

Страница 19: ...Limit Controller E5CN FR 19 ...

Страница 20: ...t exceed the individual price of the product on which liability is asserted IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY REPAIR OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED STORED INSTALLED AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION ABUSE MISUSE OR INAPPROPRIATE MODIFICATION OR REPAIR Application Considerations SUITABIL...

Отзывы: