manualshive.com logo in svg
background image

E5CK-T

  E5CK-T

170

J

OPTIONAL OUTPUT BOARDS

Description

Specifications

Compatible controller

Max. quantity

Part number

Relay/Relay

SPST/SPST, 5 A, 250 VAC

E5CK-T

1

E53-R4R4

Relay/Pulse

SPST, 5 A/NPN, 24 VDC

E5CK

1

E53-Q4R4

SPST, 5 A/PNP, 24 VDC

E5CK

1

E53-Q4HR4

Relay/Linear current

SPST, 5 A/4–20 mA

E5CK

1

E53-C4R4

SPST, 5 A/0-20 mA

E5CK

1

E53-C4DR4

Relay/Linear voltage

SPST, 5 A/0-10 VDC

E5CK

1

E53-V44R4

Pulse/Pulse

NPN/NPN, 24 VDC

E5CK

1

E53-Q4Q4

PNP/PNP, 24 VDC

E5CK

1

E53-Q4HQ4H

Computer communications

RS-232C

E5CK

1

E53-CK01

RS-485

E5CK

1

E53-CK03

Event input

For remote set point

E5CK

1

E53-CKB

Transfer output

4 to 20 mA

E5CK

1

E53-CKF

Note: If the control period is less than 5 seconds, use an SSR (solid state relay) or pulse voltage output.

J

ACCESSORIES (ORDER SEPARATELY)

Description

Specifications

Compatible controller

Max. quantity

Part number

Current transformer; order

50 A load, 5.8 mm hole dia.

E5CK-T

1

E54-CT1

only if using heater
burnout alarm function

120 A load, 12 mm hole dia.

E5CK-T

1

E54-CT3

Terminal cover (supplied
with Standard models)

Provides finger protection from
terminals (VDE0106 part 100)

E5CK-T

1

E53-COV07

Software

For setup and monitoring;
requires optional computer
communications board

All

1

SYS-CONFIG V2.0

Temperature Ranges

Platinum Resistance Thermometer

Input

 

(switch selectable)

JPt100

Pt100

Range

°

C

–199.9

°

 to 650.0

°

–199.9

°

 to 650.0

°

°

F

–199.9

°

 to 999.9

°

–199.9

°

 to 999.9

°

Resolution 

°

C/

°

F (main setting and alarm)

0.1

0.1

Thermocouple

Input (switch
selectable)

K1

K2

J1

J2

T

E

L1

L2

U

N

R

S

B

W

PLII

Range

°

C

–200
to
1,300

0.0 to
500.0

–100
to 850

0.0 to
400.0

–199.9
to
400.0

0 to
600

–100
to 850

0.0 to
400.0

–199.9
to
400.0

–200
to
1,300

0 to
1,700

0 to
1,700

100 to
1,800

0 to
2,300

0 to
1,300

°

F

–300
to
2,300

0.0 to
900.0

–100
to
1,500

0.0 to
750.0

–199.9
to
700.0

0 to
1,100

–100
to
1,500

0.0 to
750.0

–199.9
to
700.0

–300
to
2,300

0 to
3,000

0 to
3,000

300 to
3,200

0 to
4,100

0 to
2,300

Resolution

°

C/

°

F (main 

setting, alarm)

1

0.1

1

0.1

0.1

1

1

0.1

0.1

1

1

1

1

1

1

Note: 1. Setting number is factory-set to 2 (K1).

2. Thermocouple W is W/Re 5-26 (tungsten rhenium 5, tungsten rhenium 26).

Current/Voltage

Input (switch selectable)

Current input

Voltage input

4 to 20 mA

0 to 20 mA

1 to 5 V

0 to 5 V

0 to 10 V

Range

One of following ranges depending on results of scaling
–1999 to 9999
–199.9 to 999.9
–19.99 to 99.99
–1.999 to 9.999

Resolution (main setting and alarm)

Depends on range selected

Содержание E5CK-AA1-500 AC100-240

Страница 1: ...H High accuracy 100 ms sampling for analog input H Conforms to international EMC and safety standards H 24V AC DC type also available H 3 year warranty RC Ordering Information Order control output boa...

Страница 2: ...DE0106 part 100 E5CK T 1 E53 COV07 Software For setup and monitoring requires optional computer communications board All 1 SYS CONFIG V2 0 Temperature Ranges Platinum Resistance Thermometer Input swit...

Страница 3: ...units of 0 1 FS Integral reset time I 0 to 3 999 s in units of 1 s Derivative rate time D 0 to 3 999 s in units of 1 s Control period 1 to 99 s in units of 1 s Manual reset value 0 0 to 100 0 in unit...

Страница 4: ...contact discharge level 2 8kV air discharge level 3 Immunity RF interference ENV50140 10V m amplitude modulated 80 MHz to 1 GHz level 3 10 V m pulse modulated 900 MHz Immunity Conducted Disturbance E...

Страница 5: ...rd model set up the output boards for control outputs 1 and 2 before mounting the Controller 2 On a position proportional model the relay output board is already set so this setup operation is unneces...

Страница 6: ...74 Dimensions Unit mm inch J E5CK T 60 2 36 min Panel Cutouts 65 2 56 min 48 1 89 58 2 28 13 3 0 52 100 3 94 53L x 53W 44 8 X 44 8 J ACCESSORIES ORDER SEPARATELY Terminal Cover E53 COV07 44 3 1 74 44...

Страница 7: ...arefully pull the internal mechanism from the housing Refer to the drawing below J SETTING UP THE OUTPUT BOARD 1 Two rectangular holes are provided on the power board right side of Controller Fit the...

Страница 8: ...cm Adapter Panel Watertight packing Input Jumper Setting Note The jumper is factory set to TC S PT temperature input Set the jumper to temperature voltage or current input according to the sensor con...

Страница 9: ...s from external noise Solderless terminals are recommended when wiring the Controller Tighten the terminal screws using a torque no greater than 0 78 N S m or 8 kgf S cm max Be careful not to tighten...

Страница 10: ...eter inputs set the inputs to a common position TC PT as the temperature input Control Output Terminal numbers 11 and 12 are for control output 1 OUT1 The five output types and internal equalizing cir...

Страница 11: ...8 7 6 13 14 11 12 3 2 Relay specifications are as follows SPST NO 250 VAC 1 A Option Terminal numbers 1 13 and 14 are valid only when the option board is set in the Controller The following four conn...

Страница 12: ...ay key sp0 0 4 Set the target value to 50 Target value Display key 50 sp0 Step number display 5 Press the Display Key to shift to the display for the time of Step 0 Time parameter for step 0 Step time...

Страница 13: ...C 199 9 to 999 9 F Platinum resistance 1 Pt100 199 9 to 650 0 C 199 9 to 999 9 F thermometer 2 K1 200 to 1 300 C 300 to 2 300 F Thermocouple 3 K2 0 0 to 500 0 C 0 0 to 900 0 F 4 J1 100 to 850 C 100 t...

Страница 14: ...and 2 and auxiliary outputs 1 and 2 The assignment destination of each output function is restricted Refer to the tables provided under the headings Standard Models and Position Proportionate Models...

Страница 15: ...ce deviation X SP ON OFF X SP ON OFF 7 Lower limit alarm with standby sequence deviation X SP ON OFF X SP ON OFF 8 Absolute value upper limit alarm X 0 ON OFF 0 X ON OFF 9 Absolute value lower limit a...

Страница 16: ...e alarm 1 to 3 open in alarm parameters setup mode Factory setting is close in alarm n o J PARAMETER OPERATION LIST Switching to modes other than manual or protect mode is carried out using the mode s...

Страница 17: ...AT auto tuning set up the control period change PID parameters and set alarm values Level 2 Mode This is the auxiliary mode for adjusting control In this mode you can set the parameters for limiting...

Страница 18: ...tors remote SP in the local SP mode Set Point During SP Ramp Monitors the set point when the SP ramp function is used J PROTECT MODE Press twice for 1 s min Security Key protect To level 0 Press twice...

Страница 19: ...arameter of the Controller in standard control is 0 Hysteresis Heat Available when the Controller is in ON OFF control For heating cooling control Hysteresis Cool Available when the Controller is in O...

Страница 20: ...ut Shift Lower Limit Available if the input type is a thermocouple or platinum resistance thermometer See Input Shift For models E5AK EK T only Open Close hysteresis Standby time Input Shift Temperatu...

Страница 21: ...are used J OPTION MODE Event Input Assignment 1 Available for the event input function Event Input Assignment 2 Available for the event input function For models E5AK E5EK T only Event Input Assignme...

Страница 22: ...t value step 0 time step 1 target value and step 1 time The step target value can be set within a range between the lower and upper target value limits The default value is zero The step time can be s...

Страница 23: ...p 0 Set the ON OFF timing with the timing signal 1 2 ON time and time signal 1 2 OFF time parameters in Program mode ON Conditions If the ON time is shorter than the OFF time the signal will be reset...

Страница 24: ...mal the probable cause may be external noise affecting the control system Check for external noise Operation at Error Control output functions turn OFF 2 mA max at 4 to 20 mA output and output equival...

Страница 25: ...ol continues allowing normal operation Motor Calibration Error Displayed on the No 2 Display Meaning Motor calibration has ended with an error Action First correctly connect the wiring for the potenti...

Страница 26: ...Unit must be approximately 0 78 N S m or 8 kgf S cm Use the following type of solderless terminals for M3 5 screws 7 2 mm max 7 2 mm max J OPERATION The alarm outputs of a model with an alarm functio...

Страница 27: ...Model G3PA G3PB G3NH G3NA G3NE G3B Appear ance SSRs connected in parallel E5AK E5EK T 8 pcs E5CK T 4 pcs E5AK E5EK T 8 pcs E5CK T 4 pcs E5AK E5EK T 5 pcs E5CK T 2 pcs E5AK E5EK T 2 pcs E5CK T 1 piece...

Страница 28: ...8 00 Specifications subject to change without notice Printed in U S A OMRON ELECTRONICS INC One East Commerce Drive Schaumburg IL 60173 1 800 55 OMRON OMRON CANADA INC 885 Milner Avenue Scarborough On...

Отзывы: