7
.
Serial Communications Connection Procedure
12
5
"
in-t
" (Initial Setting Level) is
displayed on No. 1 display.
Press the
L
(Level) Key again
for less than 1 second.
L
(Level) Key
6
The display changes to
Communications Setting Level.
"
psel
" (Protocol Setting) and
"
cwf
" (CompoWay/F) are
displayed on No. 1 and No. 2
displays, respectively.
*If the setting value is different,
press the
U
(Up) or
D
(Down)
Key to change the parameter.
Press the
M
(Mode) Key.
< Setting value>
CWF / Mod
(default: CWF)
CWF: CompoWay/F
Mod: Modbus-RTU
M
(Mode) Key
7
"
u-no
" (Communications Unit
No.) is displayed.
Check that Communications
Unit No. is 1.
*If the setting value is different,
change it in the same way as
step 6.
Press the
M
(Mode) Key.
<Setting value>
0 to 99 (default: 1)
M
(Mode) Key
8
"
bps
" (Communications Baud
Rate) is displayed.
Check that Communications
Baud Rate is 9.6 kbps.
*If the setting value is different,
change it in the same way as
step 6.
Press the
M
(Mode) Key.
<Setting value>
9.6, 19.2, 38.4 or
57.6 kbps
(default: 9.6)
M
(Mode) Key