manualshive.com logo in svg
background image

READ AND UNDERSTAND THIS DOCUMENT

Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or comments.

WARRANTY

OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of 
sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS 
FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT 
THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR 
IMPLIED.

LIMITATIONS OF LIABILITY

OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY 
WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.

In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON’S 
ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO 
CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

SUITABILITY FOR USE

THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF 
PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES. Please refer to separate 
catalogs for OMRON's safety rated products.

OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer’s application or use 
of the product.

At the customer’s request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This 
information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other 
application or use.

The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the 
products, nor is it intended to imply that the uses listed may be suitable for the products:
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document.
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, 

and installations subject to separate industry or government regulations.

• Systems, machines, and equipment that could present a risk to life or property.

Please know and observe all prohibitions of use applicable to the products.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A 
WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED 
USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

PERFORMANCE DATA

Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of 
OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of 
Liability.

CHANGE IN SPECIFICATIONS

Product specifications and accessories may be changed at any time based on improvements and other reasons.

It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some 
specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your 
application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products.

DIMENSIONS AND WEIGHTS

Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

ERRORS AND OMISSIONS

The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or 
proofreading errors, or omissions.

PROGRAMMABLE PRODUCTS

OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof.

COPYRIGHT AND COPY PERMISSION

This document shall not be copied for sales or promotions without permission.

This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this document in 
any manner, for any other purpose. If copying or transmitting this document to another, please copy or transmit it in its entirety.

In the interest of product improvement, specifications are subject to change without notice.

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

Cat. No. E380-E1-01

OMRON Corporation

Industrial Automation Company

Technology Development Center H.Q.
Integration Strategy & Business 
Development Center

Shiokoji Horikawa, Shimogyo-ku,
Kyoto, 600-8530 Japan
Tel: (81)75-344-7123/Fax: (81)75-344-7172

Regional Headquarters

OMRON EUROPE B.V.

Wegalaan 67-69, NL-2132 JD Hoofddorp
The Netherlands
Tel: (31)2356-81-300/Fax: (31)2356-81-388

OMRON ELECTRONICS LLC

1 East Commerce Drive, Schaumburg,
IL 60173 U.S.A.
Tel: (1)847-843-7900/Fax: (1)847-843-8568

OMRON ASIA PACIFIC PTE. LTD.

83 Clemenceau Avenue, #11-01, UE Square,
239920 Singapore
Tel: (65)6835-3011/Fax: (65)6835-2711

OMRON (CHINA) CO., LTD.

Room 2211, Bank of China Tower,
200 Yin Cheng Road (M),
Shanghai, 200120 China
Tel: (86)21-5037-2222/Fax: (86)21-5037-2200

1206

Содержание E3ZM-C -

Страница 1: ...ic Sensor with Built in Amplifier 10 8 21 32 2 25 4 Two M3 holes SUS316L Oil resistant PVC cable 4 mm dia Actual Size Features 1 Oil resistant Robust and Compact IP67g Degree of Protection Only 1 8th...

Страница 2: ...screws to hold a cover so there are no worries about loose screws leading to liquid penetration And the model number is laser marked on the housing so it s always readable when the time comes to orde...

Страница 3: ...eve a detection distance of 20 m means that Sensor operation is possible even in dusty dirty environments response time 2 ms It all adds up to a more visible more dependable worksite These Connectors...

Страница 4: ...0 3 m E3ZM CT61 M1TJ E3ZM CT81 M1TJ Connector M8 4 pins E3ZM CT66 E3ZM CT86 Pre wired 2 m E3ZM CT62B E3ZM CT82B Pre wired 5 m E3ZM CT62B 5M E3ZM CT82B 5M M12 twist and click pre wired connector 0 3 m...

Страница 5: ...r e g E3ZM CT66 M5 4 Through beam Models are also available with a light emission stop function When ordering add G0 to the end of the model number e g E3ZM T61 G0 Ask your OMRON representative for de...

Страница 6: ...DC max Load current 100 mA max Residual voltage 2 V max Open collector output NPN PNP output depending on model Light ON Dark ON switch selectable Protection circuits Reversed power supply polarity pr...

Страница 7: ...ection circuits Reversed power supply polarity protection Output short circuit protection Reversed output polarity protection Mutual interference protection Response time Operate or reset 1 ms max Sen...

Страница 8: ...5 6 0 100 50 0 50 100 E39 R1S E39 R1 Y X 120 100 80 60 40 20 0 20 40 60 80 100 120 140 140 1 8 0 2 0 4 0 6 0 8 1 1 2 1 4 1 6 0 Y X Sensing object 300 300 white paper Distance Y mm Distance X m 4 2 0 2...

Страница 9: ...r ating level Excess gain ratio multiple 100 10 1 60 50 40 30 20 10 0 Distance m Oper ating level Excess gain ratio multiple 0 1 100 50 30 10 5 3 1 0 5 0 3 0 1 6 1 2 3 4 5 0 E39 R1S E39 R1 Distance m...

Страница 10: ...40 20 60 80 Inclination angle Sensing distance variation Inclination angle Center line Sensing object 40 30 20 10 0 10 20 30 40 50 50 80 40 20 60 0 40 20 60 80 Inclination angle Sensing distance varia...

Страница 11: ...ator yellow Between brown and black leads Output transistor Load e g relay NEAR FAR ON OFF ON OFF Operate Reset Operation indicator yellow Output transistor Load e g relay Between brown and black lead...

Страница 12: ...M421 402 A XS3F M421 405 A XS3F M422 402 A XS3F M422 405 A Brown White Blue Black Wire color Note The above M8 and M12 Connectors made by OMRON are IP67 Do not use them in an environment where IP69K i...

Страница 13: ...ensor Do not use the Sensor in any atmosphere or environment that exceeds the ratings Do not install the Sensor in the following locations 1 Locations subject to direct sunlight 2 Locations subject to...

Страница 14: ...in environments containing oils not listed in the table Additives in the oil may also affect performance Always test applicability in advance Test oil type Product name Kinetic viscosity at 40 C mm2...

Страница 15: ...5 20 6 10 8 32 2 11 6 4 5 21 Two M3 Optical axis Stability indicator green Operation indicator yellow Sensitivity adjuster Operation selector Receiver 4 dia vinyl insulated round cable with 3 conduct...

Страница 16: ...2 4 1 3 Retro reflective Models Connector Models E3ZM CR66 E3ZM CR86 Diffuse reflective Models Connector Models E3ZM CD67 E3ZM CD87 Terminal No Specifications 1 V 2 3 0 V 4 Output BGS Reflective Model...

Страница 17: ...MEMO Oil resistant Robust Compact Photoelectric Sensor E3ZM C 17...

Страница 18: ...MEMO 18 Oil resistant Robust Compact Photoelectric Sensor E3ZM C...

Страница 19: ...MEMO Oil resistant Robust Compact Photoelectric Sensor E3ZM C 19...

Страница 20: ...nd observe all prohibitions of use applicable to the products NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN...

Отзывы: