Transparent object sensor

Ratings and Specifications

Item

Optimised for PET

For all transparent objects

E3ZM-B_

E3ZM-B_T

Sensing distance

0 to 500 mm (Using E39-RP1); min distance to reflector: 100 mm

Standard sensing object

500-ml, transparent, round PET bottle (65-mm dia.)

Directional angle

Sensor: 3

°

 to 10

°

Reflector: 30

°

Light source (wavelength)

Red LED (650 nm)

Power supply voltage

10 to 30 VDC, including 10% ripple (p-p)

Current consumption

450 mW max. (15 mA at 30 VDC)

25 mA max.

Control output

Load power supply voltage: 30 VDC max., Load current: 100 mA max. (Residual voltage: 2 V max.)
Open-collector output (NPN/PNP output depending on model)

Operating modes

Light-ON/Dark-ON selectable by wire

Light-ON/Dark-ON switch selectable

Protective circuits

Reversed power supply polarity, load short-circuit protection, mutual interference prevention, reversed 
output polarity protection

Response time

Operation or reset: 1 ms max.

Sensitivity adjustment

Teach button

one-turn adjuster

Ambient illumination

Incandescent lamp: 3,000 lx max., Sunlight: 10,000 lx max.

Ambient temperature range

Operating: 

40 to 60

°

C (

*1

), Storage: 

40 to 70

°

(with no icing or condensation)

*1.

Do not bend the cable in temperatures of 

25

°

C or lower.

Operating: 

25 to 55°C

Storage: 

40 to 70°C (with no icing or condensation)

Ambient humidity range

Operating: 35% to 85%, Storage: 35% to 95% (with no condensation)

Insulation resistance

20 M

Ω

 min. at 500 VDC

Dielectric strength

1,000 VAC, 50/60 Hz for 1 min

Vibration resistance

Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions

Shock resistance

Destruction: 500 m/s

2

 3 times each in X, Y, and Z directions

Degree of protection

IEC 60529: IP67, DIN 40050-9: IP69K (

*2

)

*2.

IP69K Degree of protection specification (for measures for improving the protection against water ingress see page 9).
IP69K is a protection standard against high temperature and high-pressure water defined in the German standard DIN 40050,
Part 9. The test piece is sprayed with water at 80

°

C at a water pressure of 80 to 100 BAR using a specified nozzle shape at a

rate of 14 to 16 liters/min. 
The distance between the test piece and nozzle is 10 to 15 cm, and water is sprayed horizontally for 30 seconds each at 0

°

, 30

°

,

60

°

, and 90

°

 while rotating the test piece on a horizontal plane.

*4

For reflectors and mounting brackets refer to Accessories.

Connection method

Pre-wired cable (standard length: 2 m) or M8 4-pin connector

Indicator

Operating indicator (yellow), Stability indicator (green), and Teaching indicator (red)

Weight (packed state)

Pre-wired models: Approx. 90 g
Connector models: Approx. 40 g

Materials

Housing

SUS316L

Lens

PMMA (polymethylmethacrylate)

Indicator

PES (polyethersulfone)

Buttons/adjusters Fluoro rubber

PEEK (polyetheretherketone)

Cable

PVC (polyvinyl chloride)

Accessories

Instruction sheet, (special reflector E39-RP1 for E3ZM-B_-C only)

*4

Содержание E3ZM-B -

Страница 1: ...able S3J for M8 4 pin stainless steel plug with 30 cm cable S5J for M8 3 pin stainless steel plug with 30 cm cable only E3ZM B_T M1J for M12 4 pin brass plug with 30 cm cable M3J for M8 4 pin brass pl...

Страница 2: ...Standard surface mount ing pre wired models E39 L150 SUS304 1 set Telescope mounting E39 L43 SUS304 1 Protection wall mounting pre wired models E39 L151 SUS304 1 set E39 L142 SUS304 1 E39 L44 SUS304 1...

Страница 3: ...e screw mounting diagonal holes 40x60x7 5 E39 R1S Enhanced detergent resistance PVC Surface screw mounting IP69k after DIN 40050 part 9 40x60x7 5 E39 R50 20x60x6 E39 R51 Highest detergent resistance S...

Страница 4: ...rage 35 to 95 with no condensation Insulation resistance 20 M min at 500 VDC Dielectric strength 1 000 VAC 50 60 Hz for 1 min Vibration resistance Destruction 10 to 55 Hz 1 5 mm double amplitude for 2...

Страница 5: ...e Y mm Distance Y mm 40 40 0 30 20 10 0 10 20 30 200 400 600 800 1000 1200 1400 1600 Distance X m Y X 2 5 2 0 1 5 1 0 0 5 0 0 2000 500 1000 1500 0 Distance m Excess gain ratio multiple Round 500 ml PE...

Страница 6: ...ectric Sensor Main Circuit 1 2 4 3 Light incident Light interrupted ON OFF Operation indicator yellow Between brown 1 and black 4 leads Output transistor Load e g relay Operate Reset ON OFF Light inci...

Страница 7: ...ndicator yellow Between blue 3 and black 4 leads Output transistor Load e g relay Operate Reset ON OFF 4 3 2 1 10 to 30 VDC 100 mA max Control output Operation indicator Yellow Stability indicator Gre...

Страница 8: ...aching Is Successful When Teaching Is Not Successful The teaching indicator red will go out The Unit will then enter normal operating condi tion The teaching indicator red will flash slowly or quickly...

Страница 9: ...or water to enter into the connection between sensor and connec tor RECOMMENDATION To obtain the correct mounting torque a torque wrench may be used 3 Using a M12 or M8 pigtail connector Using a pigta...

Страница 10: ...te tightening torque is 0 3 to 0 4 N m When using another commercially available connector follow the usage and tightening torque instructions provided by the manufacturer Load Do not use a load that...

Страница 11: ...lector switch 4 dia vinyl insulated round cable with 3 conductors Conductor cross section 0 2 mm2 Insulator diameter 1 1 mm Standard length 2 m 1 3 2 4 M12 x 1 4 dia vinyl insulated round cable with 3...

Страница 12: ...ed may be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this document Nuclear energy control s...