background image

7

E3Z-H

Safety precautions

This product is not designed or rated for directly or 
indirectly ensuring safety of persons. Do not use it for 
such a purpose.

Do not use the product with voltage in excess of the 
rated voltage. Excess voltage may result in malfunc-
tion or fire.

Never use the product with an AC power supply. 
Otherwise, explostion may result.

When cleaning the product, do not apply a high-pres-
sure spray of water to one part of the product. Other-
wise, parts may become damaged and the degree of 
protection may be degraded.
High-temperature environments may result in burn 
injury.

The following precautions must be observed to ensure safe 
operation of the Sensor.

Operating Environment

Do not use the Sensor in an environment where explosive or 
flammable gas is present.

Connecting Connectors

Be sure to hold the connector cover when inserting or removing 
the connector. Be sure to tighten the connector lock by hand; 
do not use pliers or other tools. If the tightening is insufficient, the 
degree of protection will not be maintained and the Sensor may 
become loose due to vibration. The appropriate tightening torque 
is 0.50 N·m for M8 connectors.

Load

Do not use a load that exceeds the rated load.

Environements with Cleaners and Disinfectants 
(e.g., Food Processing Lines)

Do not use the Sensor in environments subject to cleaners and 
disifectants. They may reduce the degree of protection.

Modifications

Do not attempt to disassemble, repair, or modify the Sensor.

Outdoor Use

Do not use the Sensor in locations subject to direct sunlight.

Cleaning

Do not use thinner, alcohol, or other organic solvents. Otherwise, 
the optical properties and degree of protection may be degraded.

Surface Temperature

Burn injury may occur. The Sensor surface temperature rises de-
pending on application conditions, such as the surrounding tem-
perature and the power supply voltage. Use caution when 
operating or washing the Sensor.

Do not use the Sensor in any atmosphere or environment that 
exceeds the ratings.

Do not install the Sensor in the following locations.

(1) Locations subject to direct sunlight
(2) Locations subject to condensation due to high humidity
(3) Locations subject to corrosive gas
(4) Locations where the Sensor may receive direct vibration or 

shock

Connecting and Mounting

(1) The maximum power supply voltage is 24 VDC. Before turning 

the power ON, make sure that the power supply voltage does 
not exceed the maximum voltage.

(2) Laying Sensor wiring in the same conduit or duct as high-volt-

age wires or power lines may result in malfunction or damage 
due to induction. As a general rule, wire the Sensor in a sepa-
rate conduit or use shielded cable.

(3) Use an extension cable with a minimum thickness of 0.3 mm

2

 

and less than 100 m long.

(4) Do not pull on the cable with excessive force.
(5) Pounding the Photoelectric Sensor with a hammer or other 

tool during mounting will impair water resistance.

(6)Mount the Sensor either using the bracket (sold separately) or 

on a flat surface.

(7) Be sure to turn OFF the power supply before inserting or re-

moving the connector.

Cleaning

Never use thinner or other solvents. Otherwise, the Sensor sur-
face may be dissolved.

Power Supply

If a commercial switching regulator is used, ground the FG (frame 
ground) terminal.

Power Supply Reset Time

The Sensor will be able to detect objects 100 ms after the power 
supply is tuned ON. Start using the Sensor 100 ms or more after 
turning ON the power supply. If the load and the Sensor are con-
nected to separate power supplies, be sure to turn ON the Sensor 
first.

Turning OFF the Power Supply

Output pulses may be generated even when the power supply is 
OFF. Therefore, it is recommended to first turn OFF the power 
supply for the load or the load line.

Load Short-circuit Protection

This Sensor is equipped with load short-circuit protection, but be 
sure to not short circuit the load. Be sure to not use an output cur-
rent flow that exceeds the rated current. If a load short circuit oc-
curs, the output will turn OFF, so check the wiring before turning 
ON the power supply again. The short-circuit protection circuit will 
be reset.

Water Resistance

Do not use the Sensor in water, rainfall, or outdoors.

!

 Warning

!

 Caution

Precautions for Safe Use

Precautions for Correct Use

Содержание E3Z-H

Страница 1: ...ble M5J M8 3 pin with 30 cm cable E3Z T61H 2M E3Z T66H PNP E3Z T81H 2M E3Z T86H Retro reflective with M S R 0 1 to 4 m 1 1 Measured with E39 R1S The reflector is sold separately NPN E3Z R61H 2M E3Z R6...

Страница 2: ...L104 1 E39 L43 1 Horizontal type mounting bracket E39 L151 One set E39 L142 1 Horizontal type protective cover bracket E39 L93 One set Sensor adjuster Easy mounting to aluminum frame rail of conveyor...

Страница 3: ...ply connection Reverse polarity protection output short circuit protection mutual interference prevention output reverse protection Response time Operation or reset 1 ms max Sensitivity adjustment no...

Страница 4: ...m E39 R3 E39 R1S E39 R2 E39 R1 Excess gain ratio Operating level 100 70 50 30 10 7 5 3 1 0 7 0 5 0 3 0 1 0 50 100 150 200 250 300 Distance X m Sensing object 300 x 300 mm white paper Excess gain rati...

Страница 5: ...ween brown and black Operation indicator orange Output transistor Load Relay 4 3 1 12 to 24 VDC Brown Black Control output Blue 2 Pink Mode selector 100 mA max Operation indicator orange Stability ind...

Страница 6: ...orange 10 4 10 8 Lens 7 2 Receiver 17 2 1 25 4 M8 connector 31 10 4 2 M3 15 5 7 2 Lens Optical axis 11 18 20 8 10 4 10 8 Power indicator orange 9 75 Emitter 17 2 1 25 4 M8 connector 9 75 31 10 4 15 5...

Страница 7: ...r in the following locations 1 Locations subject to direct sunlight 2 Locations subject to condensation due to high humidity 3 Locations subject to corrosive gas 4 Locations where the Sensor may recei...

Страница 8: ...isted may be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this document Nuclear energy contro...

Отзывы: