45
Connection in line with EMC requirements
Section 7-4
7-3-3
Connector pin assignments
The sensor is connected by means of a standard 5-pole M12 connector
(see
Figure 5 Connector pin assignments)
.
Figure 5 Connector pin assignments
7-4
Connection in line with EMC requirements
• In environments with interference levels, use cables with twisted-pair
wires and/or shielded cables.
• When cables are introduced into an EMC control cabinet, guide the cable
shield without interruption through the wall of the EMC control cabinet
(e.g. via a cable conduit).
• Professionally connect the cable shield to the control cabinet housing (flat
surface, conductive).
• Professionally connect wires of cables or free cable ends that are not
used to the cable shield on both ends of the cable.
• If the control cabinet is connected by means of connectors, use connec-
tors with a metal housing and a leading protective earth contact (in
accordance with EN 60204-1) only.
• Conductively connect the cable shield to the connector housing.
• Professionally connect the mating connector to the control cabinet hous-
ing (flat surface, conductive).
• Route supply and signal leads in separate cable ducts.
• Route supply and signal leads as closely as possible to the equipotential
bonding conductor.
• Do not route cable ducts in the proximity of strong electromagnetic inter-
ference sources such as electric motors or transformers.
• Suitable protective measures conforming to EN 60204-1 must be taken if
the cable layout does not fully rule out the risk of lightning strikes.
OUT1
OUT2 / IN2
0 V
+ U
S
IN1
(View of connector pins on the sensor)
Содержание E3NT-L
Страница 1: ...OPERATION MANUAL Photoelectric Sensor Diffuse Reflective Sensor E3NT L Cat No E30E EN 01A...
Страница 7: ...8 Abbreviations Section 1 7...
Страница 8: ...9 SECTION 2 Safety Notes 2 1 Safety notes 10...
Страница 20: ...21 Dimensions Section 3 3 3 3 5 Optical data link E3NT AL232 2m order separately cable 2 m 68 9 27 30...
Страница 21: ...22 Dimensions Section 3 3...
Страница 34: ...35 SECTION 5 Transport 5 1 Packaging Transportation damage 36 5 2 Storage 36 5 3 Scope of delivery 36...
Страница 45: ...46 Connection in line with EMC requirements Section 7 4...
Страница 60: ...61 SECTION 10 Maintenance and Repair 10 1 Maintenance 62 10 2 Repair 62...
Страница 62: ...63 SECTION 11 Accessories and Parts 11 1 Accessories and parts 64...
Страница 64: ...65 SECTION 12 Appendix 12 1 Error messages 66 12 2 Factory default settings 67...