E3MC
E3MC
Function 3: Remote control of threshold adjustments
through the PLC or PC
Input either one of the following signals as remote control input.
There will be an answer-back output for 0.3 s if the signal is
correctly accepted.
No.
Control signal
All E3MC models
6
Threshold 1 selected.
7
Threshold 2 selected.
8
Threshold 3 selected.
9
Threshold 4 selected.
10
Threshold 5 selected.
11
Threshold 6 selected.
12
Threshold 7 selected.
Threshold and Display
Threshold 1
Threshold 2
Threshold 3
Threshold 4
Threshold 5
Threshold 6
Threshold 7
The following is an example of ladder programming for setting
control signals. Full control of the E3MC is possible using this
function.
TIM000, TIM001, TIM002
set values
(XXXX, YYYY, ZZZZ)
No.1: (0000, 0000, 0003)
No.2: (0000, 0000, 0006)
No.3: (0000, 0000, 0009)
No.4: (0000, 0000, 00012)
No.5: (0000, 0000, 00015)
No.6: (0003, 0003, 0003)
No.7: (0003, 0006, 0003)
No.8: (0003, 0009, 0003)
No.9: (0003, 0003, 0006)
No.10: (0003, 0006, 0006)
No.11: (0003, 0003, 0009)
No.12: (0006, 0003, 0003)
Input: 00000
Output: 00100
Others: Work bits
TIM000
#XXXX
05000
05000
00000
END
TIM001
#YYYY
05001
05001
T000
TIM000
TIM001
TIM002
#ZZZZ
05002
05002
T001
TIM002
00100
05002
05000
Note: 1. The permissible error of each signal pulse is
±
0.1 s
max.
2. A minimum interval of 0.6 s is required between
signals.
3. Threshold 4 is set after teaching.
www.DataSheet4U.com