E3MC
E3MC
2.
Color Registration
Position the registered object at the
detection point and press the TEACH
button.
All the red threshold indicators
will flash if the E3MC receives
excessive light.
All the detection level
indicators are illuminated.
Registered object
OK
No Good
Sensor
3.
Threshold Adjustment (If Required)
Sensor
Sensing target
Press the SELECT button in ADJ mode with or without
the object to be detected positioned at the detection
point.
Detection Level and Tolerance
As the detected color becomes closer to the registered
color, the number of illuminated detection level indicators
increases. When the E3MC is in conforming output mode,
the control output of the E3MC will be ON if the detection
level exceeds the threshold level and OFF if the detection
level does not exceed the threshold level.
Set the threshold to a higher level for highly-precise color
discrimination and to a lower level to ignore minor tint
differences or dirt retention.
Detection level
Operation indicator
illuminated:
Control output ON
Tolerance
Threshold
value
Detection level
Threshold
value
Operation indicator
not illuminated:
Control output OFF
4.
Operation
Detection operation is performed in RUN mode.
ON/OFF status of each bank is displayed on the
bank indicators.
Bank Indicators