Cylindrical Inductive Sensor for AC Power Supply

Specifications

Plastic Housing (E2F)

Model

E2F-X1R5Y

@

E2F-X2Y

@

E2F-X5Y

@

E2F-X10Y

@

Sensing distance

1.5 mm ±10%

2 mm ±10%

5 mm ±10%

10 mm ±10%

Setting distance

0 to 1.2 mm

0 to 1.6 mm

0 to 4 mm

0 to 8 mm

Differential distance

10% max

Sensing object

Ferrous metal (Sensitivity lowers with non-ferrous metals)

Standard sensing object

Iron, 8 x 8 x 1 mm

Iron, 12 x 12 x 1 mm

Iron, 18 x 18 x 1 mm

Iron, 30 x 30 x 1 mm

Response frequency 

*1

*1. The response frequencies are average values measured on condition that the distance between each sensing object is twice as large as the size of the sensing

object and the sensing distance set is half of the maximum sensing distance.

25 Hz

Power supply  
(Operating voltage 
range)

24 to 240 VAC (20 to 264 VAC)

Leakage current

1.7 mA at 200 VAC

Control 
output

Switching 
capacity

5 to 100 mA

5 to 300 mA

Residual 
voltage

Refer to the Specifications

Indicator lamp

Operation indicator (red LED)

Operation status 
(with sensing object 
approaching)

Y1 Models: ON
Y2 Models: NC

Protection circuit

None 

*2

*2. Short circuit protection types are available.

Ambient temperature 

Operating/Storage: –25 °C to 70 °C (with no icing or condensation)

Ambient humidity

Operating/Storage: 35% to 95% RH

Temperature influence

A maximim fluctuation of ±10% max. of sensing distance at 23 °C in the temperature range of –25 °C to 70 °C

Voltage influence

±1% max. of sensing distance within a range of ±10% of rated power supply voltage

Insulation resistance

50 M

 min. (at 500 VDC) between current carry parts and case

Vibration resistance

10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions

Shock resistance

Destruction: 1,000 m/s

2

 for 10 times each in X, Y, and Z directions

Protective structure

IEC IP68 

*3

*3.

OMRON test method

Conditions: Less than 10 m natural state under water
(1) It is not flooded underwater with two atmospheric pressure for 1 hour.
(2) A heat shock cycle (it is 1 hour, respectively to 0 °C cold water and 70 °C warm water) is repeated 20 times, and the performance of detection distance and
insulation resistance is checked.

Connection method

Pre-wired models (standard length 2 m)

Weight (Packed state)

Approx. 40 g

Approx. 50 g

Approx. 130 g

Approx. 170 g

Material

Case

Polyarylate

Sensing 
surface

Clamping 
nut

Polyarylate resin

Accessories

Instruction manual

Содержание E2E-X10MY1

Страница 1: ...ce Operation mode Model Shielded M8 1 5 mm NO E2E X1R5Y1 NC E2E X1R5Y2 M12 2 mm NO E2E X2Y1 1 2 1 Models with a different frequency are also available These models are E2E X Y 5 e g E2E X5Y15 2 Cables with a length of 5 m are also available Specify the cable length at the end of the model number e g E2E X2Y1 5M NC E2E X2Y2 M18 5 mm NO E2E X5Y1 1 2 NC E2E X5Y2 M30 10 mm NO E2E X10Y1 1 2 NC E2E X10Y...

Страница 2: ...ne 2 2 Short circuit protection types are available Ambient temperature Operating Storage 25 C to 70 C with no icing or condensation Ambient humidity Operating Storage 35 to 95 RH Temperature influence A maximim fluctuation of 10 max of sensing distance at 23 C in the temperature range of 25 C to 70 C Voltage influence 1 max of sensing distance within a range of 10 of rated power supply voltage In...

Страница 3: ... NO Y2 Models NC For details refer to Timing Charts Protection circuit Surge suppressor Ambient temperature 1 2 Operating Storage 25 C to 70 C with no icing or condensation Operating Storage 40 C to 85 C with no icing or condensation Ambient humidity Operating Storage 35 to 95 with no condensation Temperature influence 10 max of sensing distance at 23 C in the temperature range of 25 C to 70 C 15 ...

Страница 4: ...5Y1 E2F X2Y1 E2F X5Y1 E2F X10Y1 E2E Y1 NC E2F X1R5Y2 E2F X2Y2 E2F X5Y2 E2F X10Y2 E2E Y2 Operation mode Applicable models Pin arrangement NO E2E X Y1 M1 NC E2E X Y2 M1 Yes No Operates Releases ON OFF Sensing object Load Detection indicator Main circuit Load Brown Blue Yes No Operates Releases ON OFF Sensing object Load Detection indicator Note Terminals 1 and 2 are not used Load Load Note Terminals...

Страница 5: ...ensing distance X mm X Y 30 25 20 15 10 5 0 30 20 10 0 10 20 30 Distance Y mm E2E X18M E2E X10M E2E X5M E2E X2M Sensing distance X mm X Y E2E X Y Leakage current mA Supply voltage V Proximity Sensor when OFF Protective resistance AC power supply E2F X Y Power supply voltage V Proximity Sensor OFF Protective resistance AC power supply 50 60 Hz Leakage current mA E2F XjYj ...

Страница 6: ...um Iron Brass Aluminum Side length of sensing object d mm Side length of sensing object d mm Stainless steel SUS304 Stainless steel SUS304 Sensing distance X mm Sensing distance X mm E2E X Y Load current mA Load voltage V L V Load current mA Load current mA Residual output voltage Residual load voltage Proximity Sensor 24 VAC 100 VAC Residual output voltage Residual load voltage Proximity Sensor R...

Страница 7: ...inless steel SUS304 E2E X10Y E2F X10Y E2E X2MY E2E X5MY E2E X10MY E2E X18MY Sensing distance mm Side length of sensing object d mm Sensing distance mm Side length of sensing object d mm Sensing distance mm Sensing distance mm Side length of sensing object d mm Side length of sensing object d mm Sensing distance mm Side length of sensing object d mm Iron Stainless steel SUS304 Brass Aluminum t 1 mm...

Страница 8: ...e E2F X 5 that is operating at a different frequency E2E X Y E2F X Y AC 2 wire Models Blue Load Load Brown Brown Blue Power supply Power supply Note The load can be connected as shown above Model Part A Part B Length Torque Torque M8 Shielded 9 mm 9 N m 12 N m Unshielded 3 mm M12 30 N m M18 70 N m M30 180 N m Model l d D m n E2E X Y AC 2 wire Shielded M8 0 mm 8 mm 0 mm 4 5 mm 12 mm M12 0 mm 12 mm ...

Страница 9: ...Although the Proximity Sensor has a surge absorption circuit if there is any machine that has a large surge current e g a motor or weld ing machine near the Proximity Sensor connect a surge absorber to the machine Leakage Current When the Proximity Sensor is OFF the Proximity Sensor has leak age current Refer to 5 and 6 Leakage Current Characteristics In this case the load is imposed with a small ...

Страница 10: ...rallel In this case however due to the total leakage current of the Proximity Sensors the load may not reset properly It is not possible to keep the load operating continuously with Proximity Sensors A and B in simultaneous operation to sense sensing objects due to the following reason When Proximity Sensor A is ON the voltage imposed on Proximity Sensor A will drop to approximately 10 V and the l...

Страница 11: ...Oil and vibration resistant vinyl insulated round cord 6 dia 0 5 dia x 2 cores Standard length 2 m The cord can be extended up to 200 m in an independent metal conduit Note Oil and vibration resistant vinyl insulated round cord 6 dia 0 5 dia x 2 cores Standard length 2 m The cord can be extended up to 200 m in an independent metal conduit Note Oil and vibration resistant vinyl insulated round cord...

Страница 12: ...eter 1 3 mm Standard length 2 m The cable can be extended up to 200 m separate metal conduit 6 dia vinyl insulated round cable with 2 conductors D Y T Models Conductor cross section 0 5 mm2 Insulator diameter 1 9 mm Standard length 2 m Note Operation indicator red Note Operation indicator red 6 dia vinyl insulated round cable with 2 conductors Conductor cross section 0 5 mm2 Insulator diameter 1 9...

Страница 13: ...4 17 38 10 53 M12 1 M12 1 Operating indicator red Toothed washer Two clamping nuts 21 dia 9 dia 4 7 17 38 10 53 M12 1 M12 1 Operation indicator red Toothed washer Two clamping nuts 29 dia 4 24 38 10 53 M18 1 M12 1 Indicator See note Two clamping nuts Toothed washer 29 dia 14 8 dia 4 10 24 38 10 53 M18 1 M12 1 Indicator See note Toothed washer Two clamping nuts 42 dia 5 36 43 10 58 M30 1 5 M12 1 In...

Страница 14: ... PRODUCTS CONTAINED IN THIS CATALOG ARE NOT SAFETY RATED THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF PERSONS AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES Please refer to separate catalogs for OMRON s safety rated products OMRON shall not be responsible for conformity with any standards codes or regulations that apply to the combination of pro...

Отзывы: