manualshive.com logo in svg
background image

14 

Cylindrical Inductive Sensor for AC Power Supply

Warranties and Limitations of Liability

WARRANTY

OMRON’s exclusive warranty is that the products are free from 
defects in materials and workmanship for a period of one year (or 
other period if specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, 
EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, 
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE 
OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES 
THAT THE BUYER OR USER ALONE HAS DETERMINED THAT 
THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS 
OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER 
WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY 

OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDI-
RECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR 
COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE 
PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, 
WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. 
In no event shall responsibility of OMRON for any act exceed the 
individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WAR-
RANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PROD-
UCTS UNLESS OMRON’S ANALYSIS CONFIRMS THAT THE 
PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, 
AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, 
ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR 
REPAIR.

Application Considerations

SUITABILITY FOR USE 

THE PRODUCTS CONTAINED IN THIS CATALOG ARE NOT 
SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR 
ENSURING SAFETY OF PERSONS, AND SHOULD NOT BE 
RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE 
DEVICE FOR SUCH PURPOSES. Please refer to separate catalogs 
for OMRON’s safety rated products.
OMRON shall not be responsible for conformity with any standards, 
codes, or regulations that apply to the combination of products in the 
customer’s application or use of the product.

Take all necessary steps to determine the suitability of the product 
for the systems, machines, and equipment with which it will be used.
Know and observe all prohibitions of use applicable to this product.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING 
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING 
THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO 
ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS 
PROPERLY RATED AND INSTALLED FOR THE INTENDED USE 
WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

Disclaimers

CHANGE IN SPECIFICATIONS

Product specifications and accessories may be changed at any time 
based on improvements and other reasons. Consult with your 
OMRON representative at any time to confirm actual specifications 
of purchased product.

DIMENSIONS AND WEIGHTS

Dimensions and weights are nominal and are not to be used for 
manufacturing purposes, even when tolerances are shown.

In the interest of product improvement, specifications are subject to change without notice.

Cat. No. D14E-EN-01

OMRON EUROPE B.V.

Wegalaan 67-69, 
NL-2132 JD, Hoofddorp,  
The Netherlands
Phone: +31 23 568 13 00
Fax:

+31 23 568 13 88

www.eu.omron.com

Содержание E2E-X10MY1

Страница 1: ...ce Operation mode Model Shielded M8 1 5 mm NO E2E X1R5Y1 NC E2E X1R5Y2 M12 2 mm NO E2E X2Y1 1 2 1 Models with a different frequency are also available These models are E2E X Y 5 e g E2E X5Y15 2 Cables with a length of 5 m are also available Specify the cable length at the end of the model number e g E2E X2Y1 5M NC E2E X2Y2 M18 5 mm NO E2E X5Y1 1 2 NC E2E X5Y2 M30 10 mm NO E2E X10Y1 1 2 NC E2E X10Y...

Страница 2: ...ne 2 2 Short circuit protection types are available Ambient temperature Operating Storage 25 C to 70 C with no icing or condensation Ambient humidity Operating Storage 35 to 95 RH Temperature influence A maximim fluctuation of 10 max of sensing distance at 23 C in the temperature range of 25 C to 70 C Voltage influence 1 max of sensing distance within a range of 10 of rated power supply voltage In...

Страница 3: ... NO Y2 Models NC For details refer to Timing Charts Protection circuit Surge suppressor Ambient temperature 1 2 Operating Storage 25 C to 70 C with no icing or condensation Operating Storage 40 C to 85 C with no icing or condensation Ambient humidity Operating Storage 35 to 95 with no condensation Temperature influence 10 max of sensing distance at 23 C in the temperature range of 25 C to 70 C 15 ...

Страница 4: ...5Y1 E2F X2Y1 E2F X5Y1 E2F X10Y1 E2E Y1 NC E2F X1R5Y2 E2F X2Y2 E2F X5Y2 E2F X10Y2 E2E Y2 Operation mode Applicable models Pin arrangement NO E2E X Y1 M1 NC E2E X Y2 M1 Yes No Operates Releases ON OFF Sensing object Load Detection indicator Main circuit Load Brown Blue Yes No Operates Releases ON OFF Sensing object Load Detection indicator Note Terminals 1 and 2 are not used Load Load Note Terminals...

Страница 5: ...ensing distance X mm X Y 30 25 20 15 10 5 0 30 20 10 0 10 20 30 Distance Y mm E2E X18M E2E X10M E2E X5M E2E X2M Sensing distance X mm X Y E2E X Y Leakage current mA Supply voltage V Proximity Sensor when OFF Protective resistance AC power supply E2F X Y Power supply voltage V Proximity Sensor OFF Protective resistance AC power supply 50 60 Hz Leakage current mA E2F XjYj ...

Страница 6: ...um Iron Brass Aluminum Side length of sensing object d mm Side length of sensing object d mm Stainless steel SUS304 Stainless steel SUS304 Sensing distance X mm Sensing distance X mm E2E X Y Load current mA Load voltage V L V Load current mA Load current mA Residual output voltage Residual load voltage Proximity Sensor 24 VAC 100 VAC Residual output voltage Residual load voltage Proximity Sensor R...

Страница 7: ...inless steel SUS304 E2E X10Y E2F X10Y E2E X2MY E2E X5MY E2E X10MY E2E X18MY Sensing distance mm Side length of sensing object d mm Sensing distance mm Side length of sensing object d mm Sensing distance mm Sensing distance mm Side length of sensing object d mm Side length of sensing object d mm Sensing distance mm Side length of sensing object d mm Iron Stainless steel SUS304 Brass Aluminum t 1 mm...

Страница 8: ...e E2F X 5 that is operating at a different frequency E2E X Y E2F X Y AC 2 wire Models Blue Load Load Brown Brown Blue Power supply Power supply Note The load can be connected as shown above Model Part A Part B Length Torque Torque M8 Shielded 9 mm 9 N m 12 N m Unshielded 3 mm M12 30 N m M18 70 N m M30 180 N m Model l d D m n E2E X Y AC 2 wire Shielded M8 0 mm 8 mm 0 mm 4 5 mm 12 mm M12 0 mm 12 mm ...

Страница 9: ...Although the Proximity Sensor has a surge absorption circuit if there is any machine that has a large surge current e g a motor or weld ing machine near the Proximity Sensor connect a surge absorber to the machine Leakage Current When the Proximity Sensor is OFF the Proximity Sensor has leak age current Refer to 5 and 6 Leakage Current Characteristics In this case the load is imposed with a small ...

Страница 10: ...rallel In this case however due to the total leakage current of the Proximity Sensors the load may not reset properly It is not possible to keep the load operating continuously with Proximity Sensors A and B in simultaneous operation to sense sensing objects due to the following reason When Proximity Sensor A is ON the voltage imposed on Proximity Sensor A will drop to approximately 10 V and the l...

Страница 11: ...Oil and vibration resistant vinyl insulated round cord 6 dia 0 5 dia x 2 cores Standard length 2 m The cord can be extended up to 200 m in an independent metal conduit Note Oil and vibration resistant vinyl insulated round cord 6 dia 0 5 dia x 2 cores Standard length 2 m The cord can be extended up to 200 m in an independent metal conduit Note Oil and vibration resistant vinyl insulated round cord...

Страница 12: ...eter 1 3 mm Standard length 2 m The cable can be extended up to 200 m separate metal conduit 6 dia vinyl insulated round cable with 2 conductors D Y T Models Conductor cross section 0 5 mm2 Insulator diameter 1 9 mm Standard length 2 m Note Operation indicator red Note Operation indicator red 6 dia vinyl insulated round cable with 2 conductors Conductor cross section 0 5 mm2 Insulator diameter 1 9...

Страница 13: ...4 17 38 10 53 M12 1 M12 1 Operating indicator red Toothed washer Two clamping nuts 21 dia 9 dia 4 7 17 38 10 53 M12 1 M12 1 Operation indicator red Toothed washer Two clamping nuts 29 dia 4 24 38 10 53 M18 1 M12 1 Indicator See note Two clamping nuts Toothed washer 29 dia 14 8 dia 4 10 24 38 10 53 M18 1 M12 1 Indicator See note Toothed washer Two clamping nuts 42 dia 5 36 43 10 58 M30 1 5 M12 1 In...

Страница 14: ... PRODUCTS CONTAINED IN THIS CATALOG ARE NOT SAFETY RATED THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF PERSONS AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES Please refer to separate catalogs for OMRON s safety rated products OMRON shall not be responsible for conformity with any standards codes or regulations that apply to the combination of pro...

Отзывы: