Inductive Sensors

AC/DC 2-wire Models

Note: 1. The response speed is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object,

and a set distance of half the sensing distance.

2. Power supply voltage waveform: Use a sine wave for the power supply. Using a rectangular AC power supply may result in faulty reset.

Size

M12

M18

M30

Type

Shielded

Item

E2E-X3T1

E2E-X7T1

E2E-X10T1

Sensing distance

3 mm 

±

10%

7 mm 

±

10%

10 mm 

±

10%

Set distance

0 to 2.4 mm

0 to 5.6 mm

0 to 8.0 mm

Differential travel

10% max. of sensing distance

Sensing object

Ferrous metal (The sensing distance decreases with non-ferrous metal, refer to 

Engineering Data

.)

Standard sensing object

Iron, 12 x 12 x 1 mm

Iron, 18 x 18 x 1 mm

Iron, 30 x 30 x 1 mm

Response speed 
(See note 1.)

DC

1.0 kHz

0.5 kHz

0.4 kHz

AC

25 Hz

Power supply voltage 
(operating voltage range) (See note 2.)

24 to 240 VDC (20 to 264 VDC)/48 to 240 VAC (40 to 264 VAC)

Leakage current

1 mA DC max., 2 mA AC max.

Control output

Load current

5 to 100 mA

Residual volt-
age

6.0 VDC max. (Load current: 100 mA, Cable length: 2 m)
10 VAC max. (Load current: 5 mA , Cable length: 2 m)

Indicator

Operation indicator (red LED), setting indicator (green LED)

Operation mode 
(with sensing object approaching)

NO
For details, refer to 

Timing Charts

.

Protection circuits

Output load short-circuit protection (at 20 to 40 VDC), Surge suppressor

Ambient temperature

Operating: –25

°

C to 70

°

C, Storage: –40

°

C to 85

°

C (with no icing or condensation)

Ambient humidity

Operating/Storage: 35% to 95% (with no condensation)

Temperature influence

±

10% max. of sensing distance at 23

°

C in the temperature range of –25

°

C to 70

°

C

Voltage influence

±

1% max. of sensing distance in the rated voltage range 

±

15%

Insulation resistance

50 M

Ω

 min. (at 500 VDC) between current-carrying parts and case

Dielectric strength

4,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case

Vibration resistance

10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions

Shock resistance

1,000 m/s

2

 10 times each in X, Y, and Z directions

Degree of protection

IEC 60529 IP67 (JEM standard IP67g (waterproof, oil-proof))

Connection method

Pre-wired Models (standard length 2 m)

Weight (packed state)

Approx. 80 g

Approx. 140 g

Approx. 190 g

Material

Case

Brass-nickel plated

Sensing surface

PBT (polybutylene terephthalate)

Cable

PVC (polyvinyl chloride)

Clamping nuts

Brass-nickel plated

Toothed washer

Iron-zinc plated

Accessories

Instruction manual

Содержание E2E - 2

Страница 1: ...U M18 7 mm E2E X7D1 U E2E X7D2 U M30 10 mm E2E X10D1 U E2E X10D2 U Self diagnostic output function Size Sensing distance Model NO NC No Shielded M8 2 mm E2E X2D1 M1TGJ U 0 3 M E2E X2D2 M1TGJ U 0 3 M...

Страница 2: ...14 mm E2E X14MD1S M1 M30 20 mm E2E X20MD1S M1 No Shielded M8 2 mm E2E X2D1 M1G E2E X2D2 M1G M12 3 mm E2E X3D1 M1G See note E2E X3D2 M1G M18 7 mm E2E X7D1 M1G See note E2E X7D2 M1G M30 10 mm E2E X10D1...

Страница 3: ...2E X2F1 PNP NC E2E X2F2 M18 5 mm NPN NO E2E X5E1 See notes 1 2 3 and 4 NPN NC E2E X5E2 See notes 3 and 4 PNP NO E2E X5F1 PNP NC E2E X5F2 M30 10 mm NPN NO E2E X10E1 See notes 1 2 3 and 4 NPN NC E2E X10...

Страница 4: ...X2ME2 M1 PNP NO E2E X2MF1 M1 PNP NC E2E X2MF2 M1 M12 5 mm NPN NO E2E X5ME1 M1 NPN NC E2E X5ME2 M1 PNP NO E2E X5MF1 M1 PNP NC E2E X5MF2 M1 M18 10 mm NPN NO E2E X10ME1 M1 NPN NC E2E X10ME2 M1 PNP NO E2...

Страница 5: ...only 5 V max Indicator D1 Models Operation indicator red LED setting indicator green LED D2 Models Operation indicator red LED Operation mode with sensing object ap proaching D1 Models NO D2 Models NC...

Страница 6: ...voltage 2 V max Load current 200 mA Cable length 2 m Indicator Operation indicator red LED Operation mode with sensing object ap proaching E1 F1 Models NO E2 F2 Models NC For details refer to Timing C...

Страница 7: ...ls NC For details refer to Timing Charts Protection circuit Surge suppressor Ambienttemperature See notes 1 and 2 Operating Storage 25 C to 70 C with no icing or con densation Operating Storage 40 C t...

Страница 8: ...able length 2 m Indicator Operation indicator red LED setting indicator green LED Operation mode with sensing object approaching NO For details refer to Timing Charts Protection circuits Output load s...

Страница 9: ...1 0 0 8 0 6 0 4 0 2 0 3 0 2 0 1 0 0 1 0 2 0 3 0 Distance Y mm E2E X1 E2E C1 E2E CR8 Sensing distance X mm X Y X Y 30 25 20 15 10 5 0 30 20 10 0 10 20 30 Distance Y mm E2E X20M E2E X14M E2E X8M E2E X4...

Страница 10: ...X D 1 3 5 10 30 50 100 5 4 3 2 1 0 E2E X Y Load current mA Load voltage V L V Load current mA Load current mA Residual output voltage Residual load voltage Proximity Sensor 24 VAC 100 VAC Residual ou...

Страница 11: ...steel SUS304 t 1 mm Iron Copper Stainless steel SUS304 Brass Aluminum t 1 mm Iron Brass Stainless steel SUS304 Aluminum Copper t 1 mm Sensing distance mm Side length of sensing object d mm Sensing dis...

Страница 12: ...ct d mm Sensing distance mm Side length of sensing object d mm E2E X1 Iron Stainless steel SUS304 Brass Aluminum t 1 mm Sensing distance mm Side length of sensing object d mm Iron Stainless steel SUS3...

Страница 13: ...arity Therefore terminals 3 and 4 have no polarity Note 1 The load can be connected to either the V or 0 V side 2 The pin numbers in the above diagram are for the M G For M1 models pin 2 is V and pin...

Страница 14: ...models the connection between pins 3 and 4 uses an NO contact and the connection between pins 1 and 2 uses an NC contact 24 to 240 VDC 48 to 240 VAC Load Brown Blue Power supply Proximity sensor main...

Страница 15: ...dicator green ON OFF Diagnostic output see note Control output Operation indicator red ON OFF ON OFF Note The diagnostic output of the E2E X D1S is ON when there is a coil burnout or the sensing objec...

Страница 16: ...rown Power supply Note The load can be connected as shown above Note The control output and diagnostic output share the negative common terminal Therefore the loads must be connected to the positive s...

Страница 17: ...See note E2E X D2 M1 Yes NO E2E X D1S M1 M8 No NO E2E X D1 M3G NC E2E X D2 M3G Note Terminals 2 and 3 are not used Load Load Load or Load or Note 1 Terminals 1 and 2 are not used 2 Terminals 3 and 4 h...

Страница 18: ...2E X E2 M1 E2E X F2 M1 M8 NO E2E X E1 M3 E2E X F1 M3 NC E2E X E2 M3 E2E X F2 M3 Note Terminal 2 is not used Load Note Terminal 2 is not used Load Note Terminal 4 is not used Load Note Terminal 4 is no...

Страница 19: ...peration mode Applicable models Pin arrangement M8 3pin NO NC E2E X1C M5 NO NC E2E X1B M5 Operation mode Applicable models Pin arrangement NO E2E X Y1 M1 NC E2E X Y2 M1 DC Load 1 4 3 DC Load 1 4 3 Not...

Страница 20: ...del Item M8 M12 M18 M30 E2E X D DC 2 wire E2E X T1 AC DC 2 wire Shielded l 0 mm 0 mm 0 mm 0 mm d 8 mm 12 mm 18 mm 30 mm D 0 mm 0 mm 0 mm 0 mm m 4 5 mm 8 mm 20 mm 40 mm n 12 mm 18 mm 27 mm 45 mm Unshie...

Страница 21: ...0 VAC on any E2E DC Model otherwise it may explode or burn Load short circuit Do not short circuit the load or the E2E may explode or burn The E2E short circuit protection function is valid if the pol...

Страница 22: ...stics In this case the load is imposed with a small voltage and the load may not be reset Before using the Proximity Sensor make sure that this voltage is less than the load reset voltage The AC 2 wir...

Страница 23: ...Control output of Proximity Sensor 3 to 100 mA VCC Power supply voltage PLC 20 4 to 26 4 V Values in parentheses are for the following PLC model and Proximity Sensor model PLC C200H ID212 Proximity S...

Страница 24: ...Sensor B Proximity Sensor B will not operate because the voltage imposed on Prox imity Sensor B is 10 V which is too low When Prox imity Sensor A is OFF the voltage imposed on Proximity Sensor B will...

Страница 25: ...0 E2E X20MD 16 E2E X18ME F 16 E2E X18MY 16 Connector M12 Shielded M8 E2E X2D M1 G 17 E2E X1R5E M1 F M1 17 M12 E2E X3D M1 G 19 E2E X2E M1 F M1 19 E2E X2Y M1 21 M18 E2E X7D M1 G 23 E2E X5E M1 F M1 23 E2...

Страница 26: ...s 3 conductors E Models Conductor cross section 0 3 mm2 Insulator diameter 1 27 mm Standard length 2 m The cable can be extended separate metal conduit up to 200 m control output or up to 100 m diagno...

Страница 27: ...stic output Note D Models Operation indicator red setting indicator green E F Y Models Operation indicator red 6 dia round cable with 2 conductors D Y T Models 3 conductors D S E F Models Conductor cr...

Страница 28: ...ion indicator red setting indicator green E F Y Model Operation indicator red Note D Models Operation indicator red setting indicator green E F Y Model Operation indicator red Note D Models Operation...

Страница 29: ...ector Models Fig 31 E2E X8MD1 M1GJ Fig 32 E2E X7D1 M1GJ E2E X7D1 M1J T E2E X7D M1TGJ U 4 dia round cable Standard length 0 3 m 4 dia round cable Standard length 0 3 m 6 dia round cable Standard length...

Страница 30: ...14 8 dia 4 10 24 38 10 43 12 M18 1 Operation indicator red setting indicator green Toothed washer Two clamping nuts 42 dia 26 8 dia 5 13 36 43 10 48 12 M30 1 5 Operation indicator red setting indicat...

Страница 31: ...USE OR INAPPROPRIATE MODIFICATION OR REPAIR Application Considerations SUITABILITY FOR USE THE PRODUCTS CONTAINED IN THIS CATALOG ARE NOT SAFETY RATED THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFET...

Страница 32: ...f product improvement specifications are subject to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounces mu...

Отзывы: