background image

DRT2-ID16/OD16

DRT2-ID16/OD16

Dimensions 

(mm)

Remote I/O Terminal Basic Units

Remote I/O Terminal Expansion Units

Ordering Information

Remote I/O Terminal Basic Units

Remote I/O Terminal Expansion Units

Specification

Part number

16 inputs, NPN 

DRT2-ID16

16 inputs, PNP 

DRT2-ID16-1

16 outputs, NPN

DRT2-OD16

16 outputs, PNP

DRT2-OD16-1

Specification

Part number

8 expansion inputs, NPN

XWT-ID08

8 expansion inputs, PNP

XWT-ID08-1

8 expansion outputs, NPN

XWT-0D08

8 expansion outputs, PNP

XWT-OD08-1

16 expansion inputs, NPN

XWT-ID16

16 expansion inputs, PNP

XWT-ID16-1

16 expansion outputs, NPN

XWT-OD16

16 expanison outputs, PNP

XWT-OD16-1

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, divide by 25.4

Cat. No. R097-E3-1

Printed in USA

OMRON CANADA, INC.

885 Milner Avenue
Toronto, Ontario M1B 5V8

416-286-6465

OMRON ELECTRONICS LLC

One East Commerce Drive
Schaumburg, IL 60173

1-800-55-OMRON

OMRON ON-LINE

Global - http://www.omron.com
USA - http://www.omron.com/oei
Canada - http://www.omron.com/oci

7/02          Specifications subject to change without notice

Содержание DeviceNet DRT2-ID16

Страница 1: ...ounting keeps track of the ON OFF operations and total operating time so preventive maintenance can be scheduled based on service life estimates The operation counter and operating time monitor functi...

Страница 2: ...independently of control systems PLC Configurator Control I O DRT2 series Smart Slave Pneumatic valve Maintenance information Easy to view Display 2 3 Sensor Cylinder Control System Maintenance System...

Страница 3: ...nction provides notification of maintenance timing for input and output devices such as switches and actuators Energized Time Monitor Function Every six minutes the Slave records the total energized t...

Страница 4: ...nd model number for each contact e g sensors and valves comments can be set for each of the input and output contacts in the Slaves Confirmation and preparation of replacement parts when failures occu...

Страница 5: ...t Slaves that are removed from the network when correcting an error enabling more effective maintenance Improved Structural Flexibility Smallest in Its Class The width of the Basic Unit is 115 mm 77 o...

Страница 6: ...ening torque M3 power supply I O terminals 0 3 to 0 5 N m Item Specification Model number DRT2 ID16 DRT2 ID16 1 Internal I O common processing NPN PNP Number of I O points 16 inputs ON voltage 15 VDC...

Страница 7: ...NP Photocoupler Photocoupler Photocoupler Photocoupler 0 1 G V 24 VDC 0 1 G V 24 VDC Internal circuit Internal circuit Voltage step down Voltage step down DRT2 ID16 1 PNP DRT2 ID16 NPN V 10 1 11 3 12...

Страница 8: ...pansion outputs NPN XWT 0D08 8 expansion outputs PNP XWT OD08 1 16 expansion inputs NPN XWT ID16 16 expansion inputs PNP XWT ID16 1 16 expansion outputs NPN XWT OD16 16 expanison outputs PNP XWT OD16...

Отзывы: