   Smart DeviceNet Remote I/O Terminals

For more information, contact an Omron representative at 1-800-55-OMRON

Gather and Use Information for Effective 
Preventive Maintenance

Get more useful data for preventive maintenance 
when you build cost-effective parallel information 
systems for control and maintenance using Omron’s 
smart remote I/O terminals. These remote I/O 
terminals include economical expansion units that let 
you design a monitoring system for maintenance 
information.

Smart Measuring and Smart Counting

These two functions take advantage of the intelligent 
capabilities of DeviceNet. In Smart Measuring, the 
remote I/O terminals convert machine operating time 
and operational changes to data enabling monitoring 
without increasing the load between controllers. 
Smart Counting keeps track of the ON/OFF 
operations and total operating time so preventive 
maintenance can be scheduled based on service life 
estimates. The operation counter and operating time 
monitor functions cannot be used simultaneously.

What Device is Reporting Problems?

These slave units can hold comments such as device 
number, type and location to shorten troubleshooting 
by identifying fault locations and faulty devices. They 
can also be used to monitor network communication 
errors.

16-point input and output terminals, NPN or PNP 
models with DeviceNet connection

Expansion terminals available in 8-point and 16- 
point units

Input filter function eliminates noise from contact 
bounce and, using OFF response time, can capture 
pulses shorter than the communications time

Sensor inrush current protection delays accepting 
input for 100 ms after input power turns on

Inputs powered by the network power supply

Compact size saves space in control panels

Network Power Monitor function

Содержание DeviceNet DRT2-ID16

Страница 1: ...ounting keeps track of the ON OFF operations and total operating time so preventive maintenance can be scheduled based on service life estimates The operation counter and operating time monitor functi...

Страница 2: ...independently of control systems PLC Configurator Control I O DRT2 series Smart Slave Pneumatic valve Maintenance information Easy to view Display 2 3 Sensor Cylinder Control System Maintenance System...

Страница 3: ...nction provides notification of maintenance timing for input and output devices such as switches and actuators Energized Time Monitor Function Every six minutes the Slave records the total energized t...

Страница 4: ...nd model number for each contact e g sensors and valves comments can be set for each of the input and output contacts in the Slaves Confirmation and preparation of replacement parts when failures occu...

Страница 5: ...t Slaves that are removed from the network when correcting an error enabling more effective maintenance Improved Structural Flexibility Smallest in Its Class The width of the Basic Unit is 115 mm 77 o...

Страница 6: ...ening torque M3 power supply I O terminals 0 3 to 0 5 N m Item Specification Model number DRT2 ID16 DRT2 ID16 1 Internal I O common processing NPN PNP Number of I O points 16 inputs ON voltage 15 VDC...

Страница 7: ...NP Photocoupler Photocoupler Photocoupler Photocoupler 0 1 G V 24 VDC 0 1 G V 24 VDC Internal circuit Internal circuit Voltage step down Voltage step down DRT2 ID16 1 PNP DRT2 ID16 NPN V 10 1 11 3 12...

Страница 8: ...pansion outputs NPN XWT 0D08 8 expansion outputs PNP XWT OD08 1 16 expansion inputs NPN XWT ID16 16 expansion inputs PNP XWT ID16 1 16 expansion outputs NPN XWT OD16 16 expanison outputs PNP XWT OD16...

Отзывы: