background image

D5B

Specifications

Structure and Nomenclature

Structure

Contact Form

Note: Specifications for normally open (N.O.) contacts are not available.

Dimensions and Operating Characteristics

(Unit: mm)

Dimensions

M5 Type

 (The square 

@

 in the models represents the cable length. Refer to Ordering Information.)

Note: 1. Unless otherwise specified, a tolerance of 

±

0.4 mm applies to all dimensions.

2. The threads of the case are not standard; 0.5-mm pitch. Therefore standard tapping to the case is not possible for mounting.

Ratings

Characteristics

Electrical ratings

1 mA at 5 VDC to 30 mA at 30 VDC (resistive load)

Degree of protection

IP67

Durability  

*

1

Mechanical

10,000,000 operations min.

Electrical

5,000,000 operations min. (at 30 mA 30 VDC resistive load)

Operating speed

5 to 500 mm/s

Operating 
frequency

Mechanical

120 operations/min.

Electrical

60 operations/min.

Insulation resistance

100 M

Ω

 min. at 250 VDC between each terminal and 

non-current-carrying metal parts

Contact resistance

With 1 m cable:700 m

Ω

 max. (initial value)

With 3 m cable:1.9 

Ω

 max. (initial value)

With 5 m cable:3.1 

Ω

 max. (initial value)

Dielectric 
strength
(50/60 Hz 1 min)

Between terminals of 
same polarity

250 VAC (at TTP)

Between each terminal 
and non-current-carrying 
metal parts

1,000 VAC (600 VAC for M5 model)

Vibration 
resistance

Malfunction

10 to 55 Hz, 1.5-mm double amplitude  

*

2

Shock
resistance

Mechanical

1,000 m/s

2

 min.

Malfunction

300 m/s

2

 min.  

*

3

Ambient operating temperature

10

°

C to +70

°

C (with no icing)

Ambient operating humidity

30% to 95%RH

Actuator strength

14.7 N  

*

4

Weight

Switch

M5: Approx. 14 g, M8: Approx. 20 g, M10: Approx. 21 g

Cable

Approx. 10 g/m

Engineering Data

Electrical Durability (cos

φ

=1)

(Operating temperature: +5

°

C to +35

°

C, 

Operating humidity: 40% to 70%RH.)

3,000

1,000

5,000

300

200

100

700

500

0

10

20

30

40

Switching current (mA)

Dur

ability (

×

10

4

 oper

ations)

30 VDC

Note: The above figures are initial values.
*1. Durability values are calculated at an operating 

temperature of +5

°

C to +35

°

C, and an operating 

humidity of 40% to 70%RH.
Contact your OMRON sales representative for more 
detailed information on other operating environments.

*2. 16.7 Hz, 1-mm double amplitude for wobble stick models.
*3. 50 m/s

2

 min. for wobble stick models.

*4. Excluding the wobble stick models.

Reset spring

Mounting nut

Axis

Cable 
(V-HKCVV)

Resin

Base

Case (PBT)

Reset spring

Actuator
(POM)

Rubber boot 
(NBR)

Plunger
(POM)

Brown

Blue

(Normally closed contact)

2.5

2.15

(Rising part of the ball)

Clamping nut

Toothed lock washer

S-FLEX V-HKCVV
equal level, 3 dia.
0.08 mm

2

Two conductors

(see note 2)

M5

×

 0.5

(Ball 2.15R)

4.3 dia.

Resin plunger

2.4

5.9

16.2

(24.5)

8

(9.2)

*

* Operating characteristics (X, Y) measuring position

D5B-501

@

2.5

1

Clamping nut

Toothed lock washer

0.5R

4.3 dia.

Resin plunger

5.9

4.9

16.2

(27)

8

(9.2)

*

* Operating characteristics (X, Y) measuring position

S-FLEX V-HKCVV
equal level, 3 dia.
0.08 mm

2

Two conductors

(see note 2)

M5

×

 0.5

D5B-502

@

2.5

5

Clamping nut

Toothed lock washer

4.3
dia.

6

41.9

±

2

16.2

(64.1)

8

(9.2)

*

2.3
dia.

0.4
dia.

6.9

±

2

2

Stainless steel wire

* Operating characteristics (X, Y) measuring position

S-FLEX V-HKCVV
equal level, 3 dia.
0.08 mm

2

Two conductors

(see note 2)

M5

×

 0.5

D5B-551

@

http://www.ia.omron.com/

2

(c)Copyright OMRON Corporation 2007   All Rights Reserved. 

Содержание D5B -

Страница 1: ...Number Legend D5B 1 2 3 Ordering Information Type M5 M8 M10 Actuator Cable length m Model Model Hemispheric actuator 1 D5B 5011 D5B 8011 D5B 1011 3 D5B 5013 D5B 8013 D5B 1013 5 D5B 5015 D5B 8015 D5B...

Страница 2: ...5 RH Actuator strength 14 7 N 4 Weight Switch M5 Approx 14 g M8 Approx 20 g M10 Approx 21 g Cable Approx 10 g m Engineering Data Electrical Durability cos 1 Operating temperature 5 C to 35 C Operating...

Страница 3: ...a 0 08 mm2 Two conductors D5B 851 13 15 18 dia Resin plunger 9 dia Ball 4 5R 4 5 Rising part of the ball 2 5 5 5 7 3 Clamping nut Toothed lock washer 20 5 33 3 Operating characteristics X Y measuring...

Страница 4: ...ct with an actuating object The wobble stick model may break if the stroke is excessive Make sure that the total travel TT is within the reference value provided in the datasheet Attach an appropriate...

Страница 5: ...Switch or modify the Switch Doing so may result in insulation failures housing damage or physical injuries Be sure to evaluate the Switch under actual working conditions after installation Do not appl...

Страница 6: ...actuator is constantly pressed it will fail quickly and reset faults may occur Inspect the Limit Switch periodically and replace it as required Mechanical Conditions for Switch Selection The actuator...

Страница 7: ...em at high DC voltages it may be more effective to connect a capacitor and resistor across the contacts rather than the load Performing testing to determine the most suitable method O O The operating...

Страница 8: ...e selecting the model Be sure to install the Switch so that the Switch is free from dust or metal powder The actuator and the switch casing must be protected from the accumulation of dust or metal pow...

Страница 9: ...ilicon oxide accumulates on the contacts contact interference can occur and can interfere with the device Before using a Switch test it under actual application conditions including the environment an...

Страница 10: ...acteristics of the actuator If a roller arm lever actuator is used do not attempt to actuate the Limit Switch in the direction shown below Do not modify the actuator to change the OP With the long act...

Страница 11: ...r abruptly Fork Lever Lock Models Note Design the shape of the dog so that it does not come in contact with the other roller lever when the actuator is inverted Dog speed 0 5 m s max standard speed Do...

Страница 12: ...facturer of the system concerning maintenance and repairs Other The standard material for the switch seal is nitrile rubber NBR which has superior resistance to oil Depending on the type of oil or che...

Страница 13: ...may be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this catalog Nuclear energy control syste...

Отзывы: