background image

D5B

M8 Type

M10 Type

Note: 1. Unless otherwise specified, a tolerance of 

±

0.4 mm applies to all dimensions.

2. The threads of the case are not standard; 0.5-mm pitch. Therefore standard tapping to the case is not possible for mounting.

13

(15)

Resin plunger

7 dia.

(Ball 3.5R)

3.5

(Rising part of the ball)

2.5

Clamping nut

Toothed lock washer

*

16.7

7.3

4

(28)

* Operating characteristics (X, Y) measuring position

(see note 2)

M8

×

 0.5

S-FLEX V-HKCVV
equal level, 3 dia.
0.08 mm

2

Two conductors

D5B-801

@

13

(15)

Resin plunger

7 dia.

0.8R

1

2.5

Clamping nut

Toothed lock washer

*

16.7

7.3

8.5

(32.5)

* Operating characteristics (X, Y) measuring position

(see note 2)

M8

×

 0.5

S-FLEX V-HKCVV
equal level, 3 dia.
0.08 mm

2

Two conductors

D5B-802

@

13

(15)

Stainless
steel wire

7 dia. 3.9 dia.

5

2.5

Clamping nut

Toothed lock washer

*

16.7

7.3

(92.8)

3

0.6
dia.

* Operating characteristics (X, Y) measuring position

(see note 2)

M8

×

 0.5

68.8

±

2

11.8

±

2

S-FLEX V-HKCVV
equal level, 3 dia.
0.08 mm

2

Two conductors

D5B-851

@

13

15

18 dia.

Resin plunger

9 dia.

Ball 4.5R

4.5

(Rising part of the ball)

2.5

5.5

7.3

Clamping nut

Toothed lock washer

20.5

(33.3)

*

* Operating characteristics (X, Y) measuring position

(see note 2)

M10

×

 0.5

S-FLEX V-HKCVV
equal level, 3 dia.
0.08 mm

2

Two conductors

D5B-101

@

13

15

18 dia.

Stainless
steel wire

9 dia. 4.6 dia.

0.6
dia.

5

5

13.3

2.5

83.3

7.3

Clamping nut

Toothed lock washer

20.5

(111.1)

*

* Operating characteristics (X, Y) measuring position

(see note 2)

M10

×

 0.5

S-FLEX V-HKCVV
equal level, 3 dia.
0.08 mm

2

Two conductors

D5B-151

@

13

15

18 dia.

Resin plunger

9 dia.

0.9R

2.5

11.5

7.3

Clamping nut

Toothed lock washer

20.5

(39.3)

*

1

* Operating characteristics (X, Y) measuring position

(see note 2)

M10

×

 0.5

S-FLEX V-HKCVV
equal level, 3 dia.
0.08 mm

2

Two conductors

D5B-102

@

13

15

18 dia.

Stainless
steel wire

9 dia. 4.6 dia.

0.6
dia.

5

5

33.3

2.5

83.3

7.3

Clamping nut

Toothed lock washer

20.5

(111.1)

*

* Operating characteristics (X, Y) measuring position

(see note 2)

M10

×

 0.5

S-FLEX V-HKCVV
equal level, 3 dia.
0.08 mm

2

Two conductors

D5B-153

@

http://www.ia.omron.com/

3

(c)Copyright OMRON Corporation 2007   All Rights Reserved. 

Содержание D5B -

Страница 1: ...Number Legend D5B 1 2 3 Ordering Information Type M5 M8 M10 Actuator Cable length m Model Model Hemispheric actuator 1 D5B 5011 D5B 8011 D5B 1011 3 D5B 5013 D5B 8013 D5B 1013 5 D5B 5015 D5B 8015 D5B...

Страница 2: ...5 RH Actuator strength 14 7 N 4 Weight Switch M5 Approx 14 g M8 Approx 20 g M10 Approx 21 g Cable Approx 10 g m Engineering Data Electrical Durability cos 1 Operating temperature 5 C to 35 C Operating...

Страница 3: ...a 0 08 mm2 Two conductors D5B 851 13 15 18 dia Resin plunger 9 dia Ball 4 5R 4 5 Rising part of the ball 2 5 5 5 7 3 Clamping nut Toothed lock washer 20 5 33 3 Operating characteristics X Y measuring...

Страница 4: ...ct with an actuating object The wobble stick model may break if the stroke is excessive Make sure that the total travel TT is within the reference value provided in the datasheet Attach an appropriate...

Страница 5: ...Switch or modify the Switch Doing so may result in insulation failures housing damage or physical injuries Be sure to evaluate the Switch under actual working conditions after installation Do not appl...

Страница 6: ...actuator is constantly pressed it will fail quickly and reset faults may occur Inspect the Limit Switch periodically and replace it as required Mechanical Conditions for Switch Selection The actuator...

Страница 7: ...em at high DC voltages it may be more effective to connect a capacitor and resistor across the contacts rather than the load Performing testing to determine the most suitable method O O The operating...

Страница 8: ...e selecting the model Be sure to install the Switch so that the Switch is free from dust or metal powder The actuator and the switch casing must be protected from the accumulation of dust or metal pow...

Страница 9: ...ilicon oxide accumulates on the contacts contact interference can occur and can interfere with the device Before using a Switch test it under actual application conditions including the environment an...

Страница 10: ...acteristics of the actuator If a roller arm lever actuator is used do not attempt to actuate the Limit Switch in the direction shown below Do not modify the actuator to change the OP With the long act...

Страница 11: ...r abruptly Fork Lever Lock Models Note Design the shape of the dog so that it does not come in contact with the other roller lever when the actuator is inverted Dog speed 0 5 m s max standard speed Do...

Страница 12: ...facturer of the system concerning maintenance and repairs Other The standard material for the switch seal is nitrile rubber NBR which has superior resistance to oil Depending on the type of oil or che...

Страница 13: ...may be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this catalog Nuclear energy control syste...

Отзывы: