background image

271

D5A

  High-precision Switch

High-precision Switch for Detecting 
Micron-unit Displacement

Ideal for detecting and measuring wear of cutting
tools or for original point of work.

Direct input possible to microprocessors and pro-
grammable controllers.

Types available with built-in operation indicator for
ease of operation monitoring as well as a version
with fiber optics remote operation indicator.

A version with screw-type cable connector avail-
able for easy installation and maintenance.

Application Examples

Origin Position Control of an X-Y Table

Coaxiality Inspection

Checking Turret Indexing Position

Note:   

Origin can be set to a desired position and the origin 

position can be controlled using the D5A.

D5A

Motor

Motor

Note:  

 The D5A can be mounted on a jig used for checking 

deviation to inspect its coaxiality.

D5A

D5A

Note:   

Set the D5A on the turret indexing position to check if 

the turret is engaged properly at the specified position.

D5A

Turret

Содержание D5A -

Страница 1: ...e operation indicator A version with screw type cable connector avail able for easy installation and maintenance Application Examples Origin Position Control of an X Y Table Coaxiality Inspection Chec...

Страница 2: ...A 7400 Connector D5A 7403 Actuator Type Repeat accuracy Operating force Cable lead outlet Degree of protection Model Type Length Pin plunger M8 1 mm max 0 49 N max Pre wired 1 m IP67 D5A 3210 0 98 N m...

Страница 3: ...e 10 mm max Limit type 20 mm max Operating speed 1 mm to 0 5 m s Rated frequency 50 60 Hz Insulation resistance 100 MW min at 250 VDC between each terminal and ground Contact resistance 800 mW max ini...

Страница 4: ...ccuracy of 3 m max D5A 2 Series M8 Type Contact Solid state Output With Repeat Accuracy of 1 m max D5A 3 Series M16 Type Contact Solid state Output With Repeat Accuracy of 3 m max D5A 7 Series Slim Ty...

Страница 5: ...2 dia 15 dia Operation indicator fiber 2 dia approx 450 mm 13 OP FP 4 85R Ceramic plunger Seal rubber 0 8 2 5 3 dia 21 5 M5 0 5 see note S FLEX V HKCVV equal level 3 dia Two cores 0 08 mm2 1M Two cla...

Страница 6: ...ping nuts Toothed lock washer 8 dia 26 dia Operation indicator LED see note 24 1 8 inch ultra hard ball 1 2 4 PT OP 37 5 45 3 dia Nameplate M16 Type Contact Output Solid state Output D5A 7400 D5A 7410...

Страница 7: ...nut with too much force Be sure to apply the clamping torque shown in this table When mounting the Switch to a panel be sure to use the toothed lock washer attache as an accessory to M5 M8 and M16 ty...

Страница 8: ...Switches In principle two or more D5A s should not be used in an OR con figuration However they can be connected in parallel provided that both switches A and B in the above figure do not operate at...

Страница 9: ...f the D5A from machining oil or cuttings No protective cover is however pro vided together with the Switch Exercise care that excessive force is not applied to the ceramic plunger of M5 M8 or slim typ...

Отзывы: