background image

277

D5A

D5A

Precautions

Correct Use

Handling of Fiber Cable

Do not pull or impose any force exceeding 29.42 N on the fiber
cable.

Make sure that the bending radius of the fiber cable is as large as
possible and at least 25 mm.

The 40-mm portion of the fiber cable on the connector end as
shown below must not be bent.

Do not impose compressing loads on the fiber cable.

The fiber cable can be cut with OMRON’s E39-F4 Cutting Tool.

Do not impose any force exceeding 29.42 N on the cord, other-
wise the cord may break. Make sure that the bending radius of
the cord is at least 20 mm.

Mounting

For the mounting dimensions, refer to the following figures and tables.

Do not tighten the nut with too much force.
Be sure to apply the clamping torque shown in this table.

When mounting the Switch to a panel, be sure to use the toothed
lock washer attache as an accessory (to M5, M8, and M16 types
only). Use the washer on the panel surface opposite the object to
be detected by the Switch.

40 mm min.

R25 mm min.

Fiber cable

Dimensions

M5

M8

M16

Contact 

output

Solid-state 

output

A

Mounting hole

5.2

–

0.1 mm dia.

8.2

–

0.1 mm dia.

16.2

–

0.1 mm dia.

B

Panel thickness

3 to 10 mm

5 to 8 mm

5 to 13 mm

10 to 17 mm

C

Toothed lock washer

10 mm dia.

15 mm dia.

26 mm dia.

Dimensions

Slim

Limit

A

Mounting pitch

12

–

0.2 mm

20

–

0.2 mm

B

Tapping

M2.6

M4

Mounting hole

B

C

A

A

B

2.8    mm dia.

+0.2

°

0

°

4.2    mm dia.

+0.2

°

0

°

Type

Clamping torque

M5

0.98 N • m max.

M8

2.94 N • m max.

M16

9.81 N • m max.

Slim

0.29 N • m max. (M2.6 screw)

Limit

1.47 N • m max. (M4 screw)

Object 
to be 
detected

Pa
n

el

Nut

Toothed lock washer

Содержание D5A -

Страница 1: ...e operation indicator A version with screw type cable connector avail able for easy installation and maintenance Application Examples Origin Position Control of an X Y Table Coaxiality Inspection Chec...

Страница 2: ...A 7400 Connector D5A 7403 Actuator Type Repeat accuracy Operating force Cable lead outlet Degree of protection Model Type Length Pin plunger M8 1 mm max 0 49 N max Pre wired 1 m IP67 D5A 3210 0 98 N m...

Страница 3: ...e 10 mm max Limit type 20 mm max Operating speed 1 mm to 0 5 m s Rated frequency 50 60 Hz Insulation resistance 100 MW min at 250 VDC between each terminal and ground Contact resistance 800 mW max ini...

Страница 4: ...ccuracy of 3 m max D5A 2 Series M8 Type Contact Solid state Output With Repeat Accuracy of 1 m max D5A 3 Series M16 Type Contact Solid state Output With Repeat Accuracy of 3 m max D5A 7 Series Slim Ty...

Страница 5: ...2 dia 15 dia Operation indicator fiber 2 dia approx 450 mm 13 OP FP 4 85R Ceramic plunger Seal rubber 0 8 2 5 3 dia 21 5 M5 0 5 see note S FLEX V HKCVV equal level 3 dia Two cores 0 08 mm2 1M Two cla...

Страница 6: ...ping nuts Toothed lock washer 8 dia 26 dia Operation indicator LED see note 24 1 8 inch ultra hard ball 1 2 4 PT OP 37 5 45 3 dia Nameplate M16 Type Contact Output Solid state Output D5A 7400 D5A 7410...

Страница 7: ...nut with too much force Be sure to apply the clamping torque shown in this table When mounting the Switch to a panel be sure to use the toothed lock washer attache as an accessory to M5 M8 and M16 ty...

Страница 8: ...Switches In principle two or more D5A s should not be used in an OR con figuration However they can be connected in parallel provided that both switches A and B in the above figure do not operate at...

Страница 9: ...f the D5A from machining oil or cuttings No protective cover is however pro vided together with the Switch Exercise care that excessive force is not applied to the ceramic plunger of M5 M8 or slim typ...

Отзывы: