High-Coded Guard Lock Safety Door Switch

D41L

Keep your machines hygienic

• Tamper-proof safety door switch to prevent human error
• Hygienically designed switch

Unique locking mechanism prevents water 
and foreign matter from collecting
Smooth surface leaves no wiping unevenness

• Complies with ISO 14119 (Type 4/High Coded), 

ISO 13849-1 (PLe)

• ECOLAB certified

Identical mounting for left and right hinged doors

Features

Refer to 

Safety Precautions

 on page18

Large actuator tolerances

• Actuator tolerance in

longitudinal direction ± 3.5 mm,

lateral direction ± 2.0 mm

Easy latching force adjustment

• The latching force can be increased 

from 25 N to 50 N simply 

by turning the star handle 180°.

• Position I: approx. 25 N,

Position II: approx. 50 N

LED display

• Smart diagnostic 

by means of 3-color LED's

• LED red: Fault

LED yellow: Status

LED green: Power

For the most recent information on models that have been certified for 
safety standards, refer to your OMRON website.

*

The actuator is sold separately.

±3.5 mm

±2.0 mm

A high-coded safety switch is defined as one where a sensor is paired with a high level coded actuator for which more than 1,000 variations are 
available.

Содержание D41L

Страница 1: ...ances Actuator tolerance in longitudinal direction 3 5 mm lateral direction 2 0 mm Easy latching force adjustment The latching force can be increased from 25 N to 50 N simply by turning the star handl...

Страница 2: ...ding 2 High Individual coding No limitation 3 OSSD configuration Y Guard monitoring AND lock monitoring Z Only guard monitoring 4 Diagnosis output D With diagnosis output 5 Lock release logic A Power...

Страница 3: ...ing Emergency exit D41L 2YDAE N2 Power to lock Solenoid lock High Individual coding Only guard monitoring D41L 1ZDG N2 High Individual coding No limitation Only guard monitoring D41L 2ZDG N2 High Indi...

Страница 4: ...Standards EN ISO 13849 1 PL e Category 4 EN 60947 5 3 IEC 61508 EN 300 330 EN ISO 14119 UL Certification UL508 CAN CSA C22 2 No 14 Regions where D41L can be used The product can be used in Japan the...

Страница 5: ...al short circuit current 100 A External device fuse rating 2 A T Safety input Switching thresholds 3 V to 5 V low 15 V to 30 V high Current consumption per input 5 mA 24 V max Accepted test pulse dura...

Страница 6: ...ting speed 0 5 m s max Mechanical durability 1 000 000 operations min Mechanical durability when used as door stop 50 000 operations min Material Fiberglass reinforced thermoplastic self digestion Enc...

Страница 7: ...afety door switches are involved in the same safety function the PFH values of the individual components must be added UL This device is intended to be powered by a Listed Limited Voltage Limited Curr...

Страница 8: ...ed 3 Star handle adjustable latching force 25 N or 50 N 4 Mounting hole for M6 screws 5 Connector plug M12 8 pole 6 Manual release 7 LED display 8 Triangular both sides for installation of the emergen...

Страница 9: ...When connecting multiple safety door switches in series apply 24 VDC to safety inputs X1 and X2 on the Nth unit as shown in the figure below Connect safety outputs Y1 and Y2 to safety inputs X1 and X2...

Страница 10: ...al User s Manual Refer to the Dual Channel Evaluation in No Z400 Example Set discrepancy time to 0 disabled or 100 ms or more G9SP series Safety Controller User s Manual Refer to the Dual Channel Eval...

Страница 11: ...op The safety outputs switch off and the guard system can be opened The blocked position is cancelled by turning the lever in the opposite direction In the unlocked position the guard system is secure...

Страница 12: ...ctivated code is definitively saved For ordering suffix D41L 1 the thus executed allocation of safety door switch and actuator is irreversible When the above procedure is attempted with a D41L 1 which...

Страница 13: ...yed shutdown of the safety outputs Refer to Troubleshooting on page 17 Safety outputs are disabled if the error warning is active for 30 minutes The signal combination auxiliary output disabled and sa...

Страница 14: ...s Unit mm Sensors D41L D N2 87 4 78 102 6 43 34 dia 9 2 25 95 3 13 3 6 5 d i a 6 3 d i a 120 3 17 5 34 4 D41L D E N2 17 5 55 34 4 87 4 78 102 6 43 34 dia 9 2 25 95 3 13 3 6 5 d i a 120 3 6 3 d i a 128...

Страница 15: ...Actuator Sold separately Accessory Sold separately D41L A1 55 16 4 127 6 7 dia 35 18 5 37 4 8 6 46 23 4 5 dia Mounting plate Mounting Set Mounting plate D41L MP 40 24 R2 5 101 R 1 5 R 8 18 5 78 8 6 8...

Страница 16: ...ce inherent to this kind of system and any reduction of the switching distances please observe the following guidelines The presence of metal chips in the vicinity of the safety door switch is liable...

Страница 17: ...uts Y1 Y2 Auxiliary output OUT Power to unlock Power to lock Green Red Yellow D41L Y D41L Z Guard open 24 V 0 V 0 V 24 V On Off Off 0 V 0 V 0 V Door closed not locked 24 V 0 V On Off Flashes 0 V 24 V...

Страница 18: ...to do so may result in serious injury or death Make sure that the DC power supply meets the following items Failure to do so may result in serious injury or death Satisfies the requirements of PELV p...

Страница 19: ...protection under continuous water exposure environment 19 Do not tamper the product with a replacement actuator Store replacement actuators in a safe place where they cannot be easily reached 20 Buil...

Страница 20: ...uld not be possible to lock the guard door from inside Maintenance Maintenance frequency SIL3 PLe at least once a month SIL2 PLd at least once a year Daily inspection For each guard door check that th...

Страница 21: ...CONNECTED WITH THE PRODUCTS WHETHER SUCH CLAIM IS BASED IN CONTRACT WARRANTY NEGLIGENCE OR STRICT LIABILITY Further in no event shall liability of Omron Companies exceed the individual price of the Pr...

Страница 22: ...D41D A3 Installation example sliding door narrow space Compact size for acrylic glass doors For the most recent information on models that have been certified for safety standards refer to your OMRON...

Отзывы: