Safety Precautions

Be sure to read the precautions for all models in the website at: http://www.ia.omron.com/.

Warning Indications

Meaning of Product Safety Symbols

Alert Statements

Use only appropriate components or devices 
complying with relevant safety standards 
corresponding to the required performance level and 
safety category. Failure to do so may result in serious 
injury or death. Conformity to requirements of the 
performance level and safety category must be 
determined as an entire system. It is recommended to 
consult a certification body regarding assessment of 
conformity to the required safety level.

Do not apply DC voltages exceeding the rated 
voltages, nor any AC voltages to the product. 
Failure to do so may result in serious injury or death.

Install the switch and actuator in a position where the 
opening of the guard door can be detected within a 
safe distance. Failure to do so may result in serious 
injury or death.

Do not apply force exceeding the specified holding 
force (Fzh). Either install another locking component 
(e.g., a hook) in addition to the product, or use a 
warning measures or an indicator showing the 
controlled system is locked to avid overloading the 
holding force in lock mode. Failure to do so may result 
in serious injury or death.

When complying with safety standards, install the 
product in an appropriate manner in accordance with 
ISO 14119, with due consideration of the risk of defeat 
by the operator. Failure to do so may result in serious
injury or death.

Make sure that the DC power supply meets the 
following items. Failure to do so may result in serious 
injury or death.
- Satisfies the requirements of PELV power supply 

defined in IEC 60204-1.

- Satisfies the requirements of class 2 circuits defined 

in UL508.

1.

Disconnect the product from power supply when wiring the 

product. Failure to do so may cause unexpected operation of 

devices connected to the product.

2.

Wire the input and output terminals correctly and verify the correct 

operation of the product before using the system in which the 

product is incorporated. Incorrect wiring may lead to loss of the 

safety function.

3.

Install the actuator in a place where it will not come in contact with 

your body when opening or closing the guard door. Failure to do 

so may result in injury.

4.

Do not use the product in any direction other than the specified 

mounting orientations of the main body and actuator.

5.

Dispose of the product in accordance with the laws set by each 

country.

 

WARNING

Indicates a potentially hazardous 
situation which, if not avoided, will 
result in minor or moderate injury, or 
may result in serious injury or death. 
Additionally there may be significant 
property damage.

Precautions for 

Safe Use

Supplementary comments on what to 
do or avoid doing, to use the product 
safely.

Precautions for 

Correct Use

Supplementary comments on what to 
do or avoid doing, to prevent failure to 
operate, or undesirable effect on 
product performance.

General prohibition

Instructions on unspecified prohibited action.

General instructions

Instructions on unspecified general action.

 

WARNING

Precautions for Safe Use

Содержание D41L

Страница 1: ...ances Actuator tolerance in longitudinal direction 3 5 mm lateral direction 2 0 mm Easy latching force adjustment The latching force can be increased from 25 N to 50 N simply by turning the star handl...

Страница 2: ...ding 2 High Individual coding No limitation 3 OSSD configuration Y Guard monitoring AND lock monitoring Z Only guard monitoring 4 Diagnosis output D With diagnosis output 5 Lock release logic A Power...

Страница 3: ...ing Emergency exit D41L 2YDAE N2 Power to lock Solenoid lock High Individual coding Only guard monitoring D41L 1ZDG N2 High Individual coding No limitation Only guard monitoring D41L 2ZDG N2 High Indi...

Страница 4: ...Standards EN ISO 13849 1 PL e Category 4 EN 60947 5 3 IEC 61508 EN 300 330 EN ISO 14119 UL Certification UL508 CAN CSA C22 2 No 14 Regions where D41L can be used The product can be used in Japan the...

Страница 5: ...al short circuit current 100 A External device fuse rating 2 A T Safety input Switching thresholds 3 V to 5 V low 15 V to 30 V high Current consumption per input 5 mA 24 V max Accepted test pulse dura...

Страница 6: ...ting speed 0 5 m s max Mechanical durability 1 000 000 operations min Mechanical durability when used as door stop 50 000 operations min Material Fiberglass reinforced thermoplastic self digestion Enc...

Страница 7: ...afety door switches are involved in the same safety function the PFH values of the individual components must be added UL This device is intended to be powered by a Listed Limited Voltage Limited Curr...

Страница 8: ...ed 3 Star handle adjustable latching force 25 N or 50 N 4 Mounting hole for M6 screws 5 Connector plug M12 8 pole 6 Manual release 7 LED display 8 Triangular both sides for installation of the emergen...

Страница 9: ...When connecting multiple safety door switches in series apply 24 VDC to safety inputs X1 and X2 on the Nth unit as shown in the figure below Connect safety outputs Y1 and Y2 to safety inputs X1 and X2...

Страница 10: ...al User s Manual Refer to the Dual Channel Evaluation in No Z400 Example Set discrepancy time to 0 disabled or 100 ms or more G9SP series Safety Controller User s Manual Refer to the Dual Channel Eval...

Страница 11: ...op The safety outputs switch off and the guard system can be opened The blocked position is cancelled by turning the lever in the opposite direction In the unlocked position the guard system is secure...

Страница 12: ...ctivated code is definitively saved For ordering suffix D41L 1 the thus executed allocation of safety door switch and actuator is irreversible When the above procedure is attempted with a D41L 1 which...

Страница 13: ...yed shutdown of the safety outputs Refer to Troubleshooting on page 17 Safety outputs are disabled if the error warning is active for 30 minutes The signal combination auxiliary output disabled and sa...

Страница 14: ...s Unit mm Sensors D41L D N2 87 4 78 102 6 43 34 dia 9 2 25 95 3 13 3 6 5 d i a 6 3 d i a 120 3 17 5 34 4 D41L D E N2 17 5 55 34 4 87 4 78 102 6 43 34 dia 9 2 25 95 3 13 3 6 5 d i a 120 3 6 3 d i a 128...

Страница 15: ...Actuator Sold separately Accessory Sold separately D41L A1 55 16 4 127 6 7 dia 35 18 5 37 4 8 6 46 23 4 5 dia Mounting plate Mounting Set Mounting plate D41L MP 40 24 R2 5 101 R 1 5 R 8 18 5 78 8 6 8...

Страница 16: ...ce inherent to this kind of system and any reduction of the switching distances please observe the following guidelines The presence of metal chips in the vicinity of the safety door switch is liable...

Страница 17: ...uts Y1 Y2 Auxiliary output OUT Power to unlock Power to lock Green Red Yellow D41L Y D41L Z Guard open 24 V 0 V 0 V 24 V On Off Off 0 V 0 V 0 V Door closed not locked 24 V 0 V On Off Flashes 0 V 24 V...

Страница 18: ...to do so may result in serious injury or death Make sure that the DC power supply meets the following items Failure to do so may result in serious injury or death Satisfies the requirements of PELV p...

Страница 19: ...protection under continuous water exposure environment 19 Do not tamper the product with a replacement actuator Store replacement actuators in a safe place where they cannot be easily reached 20 Buil...

Страница 20: ...uld not be possible to lock the guard door from inside Maintenance Maintenance frequency SIL3 PLe at least once a month SIL2 PLd at least once a year Daily inspection For each guard door check that th...

Страница 21: ...CONNECTED WITH THE PRODUCTS WHETHER SUCH CLAIM IS BASED IN CONTRACT WARRANTY NEGLIGENCE OR STRICT LIABILITY Further in no event shall liability of Omron Companies exceed the individual price of the Pr...

Страница 22: ...D41D A3 Installation example sliding door narrow space Compact size for acrylic glass doors For the most recent information on models that have been certified for safety standards refer to your OMRON...

Отзывы: