background image

D2MQ

D2MQ

210

Specifications

 Ratings

Type

Silver-plated contact type

Gold-plated contact type

Rated voltage

Item

Resistive load

30 VDC

0.5 A

50 mA

Note:

The ratings values apply under the following test conditions: 
Ambient temperature: 20

±

2

°

C

Ambient humidity: 65

±

5%

Operating frequency: 30 operations/min

 Characteristics

Operating speed 
(see note 2)

0.1 mm to 0.5 m/s

Operating frequency

Mechanical: 60 operations/min max.
Electrical:

30 operations/min max.

Insulation resistance

100 M

 min. (at 250 VDC)

Contact resistance 
(initial value)

100 m

 max.

Dielectric strength

500 VAC, 50/60 Hz for 1 min between terminals at the same polarity
500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground

Vibration resistance 
(see note 3)

Malfunction: 10 to 55 Hz, 1.5-mm double amplitude (see note 2)

Shock resistance 
(see note 3)

Destruction: 1,000 m/s

2

 {approx. 100G} max.

Malfunction: 300 m/s

2

 {approx. 30G} max.

Durability (see note 4)

Mechanical: 30,000 operations min. (60 operations/min)
Electrical:

10,000 operations min. (30 operations/min)

Degree of protection

IEC IP40

Degree of protection
against electric shock

Class I

Proof tracking index (PTI)

175

Ambient operating
temperature

–15

°

C to 70

°

C (at ambient humidity of 60% max.) (with no icing)

Ambient operating
humidity

35% to 85% (for 5

°

C to 35

°

C)

Weight

Approx. 0.3 g

Note:

1. The data given above are initial values.

2. The values are for the pin plunger models. (For different models, consult your OMRON representative.)

3. Malfunction: 1 ms max.

4. For testing conditions, consult your OMRON sales representative.

 Contact Specifications

Item

Silver-plated

contact type

Gold-plated

contact type

Contact

Specification

Rivet

Material

Silver plated

Gold plated

Gap (standard
value)

0.15 mm

Inrush

t

NC

0.5 A max.

0.05 A max.

current

NO

0.5 A max.

0.05 A max.

Minimum applicable load

50 mA 
at 5 VDC

5 mA at 5 VDC

 Contact Form

SPDT

Содержание D2MCML-1O5-1

Страница 1: ...terminals TR Right angled terminals D2MQ 4L 1 1 2 3 1 Actuator 4L Hinge leaf lever 2 Contact Material Rating None Silver plated 0 5 A at 30 VDC 105 Gold plated 50 mA at 30 VDC 3 Terminals None Straig...

Страница 2: ...3 Destruction 1 000 m s2 approx 100G max Malfunction 300 m s2 approx 30G max Durability see note 4 Mechanical 30 000 operations min 60 operations min Electrical 10 000 operations min 30 operations min...

Страница 3: ...ent temperature 20 2 C Ambient humidity 65 5 Without load Operating frequency 120 operations min Ambient temperature 20 2 C Ambient humidity 65 5 Operating frequency 20 operations min OT Full stroke c...

Страница 4: ...OP 6 7 0 5 mm OF max 0 39 N 40 gf RF min g 0 04 N 4 gf PT max 2 1 mm OT min 0 3 mm MD max 0 7 mm FP max 8 7 mm OP 7 1 0 5 mm Pin Plunger Models D2MQ 1 Straight Terminals D2MQ 1 TL Left angled terminal...

Страница 5: ...uator and leaf lever Provide an amount of OT that equals or exceeds the standard Do not change the operating position by modifying the actuator Do not use the Switch in an application where the operat...

Страница 6: ...eak an alternating current or a direct current Be sure to check both the AC and DC ratings of a switch The control capacity will drop drastically if it is a DC load This is be cause a DC load unlike a...

Страница 7: ...capacitor has no polarity If however the ability to control arcs between contacts is a problem for high DC voltage it may be more effective to connect a capacitor and resistor between the contacts ac...

Страница 8: ...ching Speed and Frequency The switching frequency and speed of a switch have a great influ ence on the performance of the switch Pay attention to the follow ing If the actuator is operated too slowly...

Страница 9: ...n impact driver as it may cause contacts stick or switch damage Screw Flat washer Spring washer Resin Incorrect Correct Do not modify the switch in any way for example by widening the mounting holes L...

Страница 10: ...the switch in places with water or oil spray Do not use a switch under the condition where vibration or shock is continuously applied to the switch If continuous vibration or shock is applied to a sw...

Страница 11: ...The sliding part of the actuator has been damaged because an excessive force was applied on the actuator Make sure that no excessive force is applied to the actuator or use an auxiliary actuator mecha...

Отзывы: