background image

D2MQ

D2MQ

212

 Dimensions and Operating Characteristics

Note:

1. All units are in millimeters unless otherwise indicated.

2. Unless otherwise specified, a tolerance of 0.15 mm applies to all dimensions.

3. The following illustrations are for the straight terminal models. Those for the left-angled terminals and right-angled terminals are

different from straight terminal models in terminal size only. Refer to Terminals on page 211 for these terminals.

4. The operating characteristics are for operation in the A direction ( ).

OF max.

1.18 N {120 gf}

RF min.

{

g }

0.19 N {20 gf}

PT max.

0.4 mm

OT min.

0.1 mm

MD max.

0.1 mm

OP

5.7

±

0.2 mm

OF max.

0.59 N {60 gf}

RF min.

{

g }

0.08 N {8 gf}

PT max.

2.4 mm

OT min.

0.3 mm

MD max.

0.7 mm

FP max.

9.6 mm

OP

6.7

±

0.5 mm

OF max.

0.39 N {40 gf}

RF min.

{

g }

0.04 N {4 gf}

PT max.

2.1 mm

OT min.

0.3 mm

MD max.

0.7 mm

FP max.

8.7 mm

OP

7.1

±

0.5 mm

Pin Plunger Models

D2MQ-1 (Straight Terminals)
D2MQ-1-TL (Left-angled terminals)
D2MQ-1-TR (Right-angled terminals)
D2MQ-1-105 (Straight Terminals)

Two, 1.6

+0.1
0

dia.

0.8

8.1

Plastic pin plunger

PT

OP

1.6

5.0

0.8

1.3

1.6

2.1

8.2

2.5 2.5

4

±

0.05

2.6

0.45

6.5

0.6
2.7

A

0.6R (plastic
leaf lever)

FP

OP

1.6

5.0

Two, 1.6

+0.1
0

dia.

0.8

1.3

1.6

2.1

8.2

2.5 2.5

4

±

0.05

2.6

0.45

6.5

0.6
2.7

8.1

7.7R

Leaf Lever Models

D2MQ-1L (Straight Terminals)
D2MQ-1L-TL (Left-angled terminals)
D2MQ-1L-TR (Right-angled terminals)
D2MQ-1L-105 (Straight Terminals)

A

Hinge Leaf Lever Models

D2MQ-4L-1

D2MQ-4L-105-1

D2MQ-4L-1-L

D2MQ-4L-105-1-L

D2MQ-4L-1-R

D2MQ-4L-105-1-R

8.1

5.35

±

0.1

0.5R

6.3R

0.7R

6.6

5.9

OP

FP

Two, 1.6       dia.

+0.1

0

0.8

1.3

3.1 (straight terminals)

1.6

4.45

0.45

2.6

2.4

0.8

0.6

2.7

8.2

2.5

2.5

1.6

2.1

4.0

±

0.05

A

Содержание D2MCML-1O5-1

Страница 1: ...terminals TR Right angled terminals D2MQ 4L 1 1 2 3 1 Actuator 4L Hinge leaf lever 2 Contact Material Rating None Silver plated 0 5 A at 30 VDC 105 Gold plated 50 mA at 30 VDC 3 Terminals None Straig...

Страница 2: ...3 Destruction 1 000 m s2 approx 100G max Malfunction 300 m s2 approx 30G max Durability see note 4 Mechanical 30 000 operations min 60 operations min Electrical 10 000 operations min 30 operations min...

Страница 3: ...ent temperature 20 2 C Ambient humidity 65 5 Without load Operating frequency 120 operations min Ambient temperature 20 2 C Ambient humidity 65 5 Operating frequency 20 operations min OT Full stroke c...

Страница 4: ...OP 6 7 0 5 mm OF max 0 39 N 40 gf RF min g 0 04 N 4 gf PT max 2 1 mm OT min 0 3 mm MD max 0 7 mm FP max 8 7 mm OP 7 1 0 5 mm Pin Plunger Models D2MQ 1 Straight Terminals D2MQ 1 TL Left angled terminal...

Страница 5: ...uator and leaf lever Provide an amount of OT that equals or exceeds the standard Do not change the operating position by modifying the actuator Do not use the Switch in an application where the operat...

Страница 6: ...eak an alternating current or a direct current Be sure to check both the AC and DC ratings of a switch The control capacity will drop drastically if it is a DC load This is be cause a DC load unlike a...

Страница 7: ...capacitor has no polarity If however the ability to control arcs between contacts is a problem for high DC voltage it may be more effective to connect a capacitor and resistor between the contacts ac...

Страница 8: ...ching Speed and Frequency The switching frequency and speed of a switch have a great influ ence on the performance of the switch Pay attention to the follow ing If the actuator is operated too slowly...