84
Counter (Block Model 208)
Section 6-12
6-12-1 Face Plates
The Counter counts ON/OFF transitions of a contact input and indicates when
the count exceeds the preset count SV. A prediction SV can be set for early
notification.
1: Status Display
The Counter face plate does not provide a status display.
2: Y1 Value Display
A Numeral Display and Input object is used to display the value of tag ITEM
Y1 (ITEM 009).
A Control Flag is set to disable input.
3: SP Numerical Value Display and Input
A Numeral Display and Input object is used to display the value of tag ITEM
SP (ITEM 007). Touch this field to display a ten-key pad below it.
Data is written to the write address of tag ITEM SP (ITEM 007) using the
Before Writing Numeral/String macro.
$W2047=GETNUMVAL();
WRITECMEM([SP_W],$W2047,1);
RETURN(1);
The upper and lower limits are 0 to 9,999.
4: PRS Numerical Value Display and Input
A Numeral Display and Input object is used to display the value of tag ITEM
PRS (ITEM 008). Touch this field to display a ten-key pad below it.
Data is written to the write address of tag ITEM PRS (ITEM 008) using the
Before Writing Numeral/String macro.
1
2
9
3
4
5
6
7
8
10
Содержание CXONE-ALD-V4 - 10-2010
Страница 2: ......
Страница 4: ...iv...
Страница 6: ...vi...
Страница 14: ...xiv...
Страница 22: ...6 Upgrades Made for Version 3 1 Section 1 6...
Страница 28: ...12 Uninstalling the Face Plate Auto Builder for NS Section 2 2...
Страница 29: ...13 SECTION 3 Basic Operation Flow 3 1 Basic Operation Flow 14...
Страница 40: ...24 Merging Projects Section 4 2...
Страница 142: ...126 Segment Program 3 Block Model 158 Section 6 19...
Страница 144: ...128 Revision History...