manualshive.com logo in svg
background image

Содержание CX-Programmer

Страница 1: ......

Страница 2: ...display the PDF files from the Start menu on your desktop after installing the CX Programmer The screen views used in this guide may be different from the actual view and be subject to change without...

Страница 3: ...0 Second Clock Pulse Bit 5 14 Entry of Advanced Instructions 2 Entry of Differential 5 15 Entry of OR Rung 5 16 Entry of Advanced Instructions 3 Entry by Fun No 5 17 Entry of Timer Instructions 5 18 E...

Страница 4: ...ned while the user is connected to the Internet http support microsoft com kb 917607 en us Windows 2000 Service Pack 2 or later Windows XP PC IBM PC AT Compatible CPU DOS V IBM AT compatible computer...

Страница 5: ...C200HE CPU11 32 42 C200HX CPU34 Z CPU44 Z CPU54 Z CPU64 Z CPU65 Z CPU85 Z C200HG CPU33 Z CPU43 Z CPU53 Z CPU63 Z C200HE CPU11 Z CPU32 Z CPU42 Z C200HS CPU01 03 21 23 31 33 CP1H X XA Y CP1L M L CPM2A 2...

Страница 6: ......

Страница 7: ......

Страница 8: ...talled Installation takes about 5 to 20 minutes depending on your PC 5 minutes for a PC with CPU Celeron2 2GHz main memory 512MB and CD ROM drive 48x To change modify delete CX Programmer after instal...

Страница 9: ...ms of the license agreement radio button and click Next button Select the radio button Click Next User information dialog box is displayed Enter User Company License product serial number of CX Progra...

Страница 10: ...click Next Click Install CX Programmer installation is started Select the radio button Complete Click Next Choose Destination Location dialog box is displayed If OMRON FB Library is selected Choose De...

Страница 11: ...wizard Now installation is completed By checking Online registration check box you can proceed to online registration Installation to Startup Installation to Startup Opening a new project Opening a n...

Страница 12: ...ton to cancel online registration Online Registration dialog box is displayed every time CX Programmer is started 2 If you do not have Internet environment or you do not want to register online fill a...

Страница 13: ...MEMO...

Страница 14: ...ammer 2 Startup of CX Programmer The initial screen when starting up CX Programmer is displayed Installation to Startup Installation to Startup Opening a new project Opening a new project Device type...

Страница 15: ...button to show the Device Type Settings dialog Click the left mouse button Click the left mouse button on and select a CPU type Click OK to decide the selected CPU type Installation to Startup Instal...

Страница 16: ...er program Ladder Window Controls programs and data Enables you to copy data by the element by executing Drag and Drop between different projects or within a project Project Workspace Project Tree Ena...

Страница 17: ...cted a key operation guide will be displayed at the bottom of the display Display in Full View Right mouse click Display in Normal View When Alt is pressed When Shift is pressed When Ctrl is pressed 4...

Страница 18: ...ram tree are available Moreover program upload by section is possible and it enables you to do online operation smoothly Giving names indicating the contents of processing or controls is possible Ther...

Страница 19: ...e to go to each section a ladder block from a section list Perform the same operation as the previous page to name the inserted section Double click a section that you want to check its ladder As chec...

Страница 20: ...necessary Windows Normal screen Alt 1 Press from a keyboard To delete Project Workspace Press Alt 1 to show Project Workspace again Alt 2 Press from a keyboard To delete Output Window Press Alt 2 to s...

Страница 21: ...5 Program Creation Coding of a simple program is explained here...

Страница 22: ...nt ENT 0 of the upper digit of an address is omitted when shown period is displayed between a channel number and a relay number Deletion of instructions z Move the cursor to the instruction and then p...

Страница 23: ...n the following message is displayed and you can notice that the coil is duplicated right away Press the ESC key to close the open Output Window The place of a duplicated coil in the program is displa...

Страница 24: ...Click the check box to remove the check mark The comment entry dialog is not displayed anymore 2 Click the toolbar button Show Program Section Comments to switch the display of the comments shown in...

Страница 25: ...from the popup menu Click the right mouse button on the bit number of the copy destination and select Paste The comments of the selected two bits are copied Copy Paste of symbol comments is possible b...

Страница 26: ..._at_Startup Enter a rung comment ENT 5 5 Entry of Normally Closed Contact 1 ENT Sensor 1 ENT Press from a keyboard to show the New Closed Contact dialog Installation to Startup Installation to Startup...

Страница 27: ...which you want to write an annotation Alt ENT Or click the right mouse button Properties The entry screen shows up Enter Mar 2002 Added by Tanaka Maintenance Dept ENT Press Alt A to switch showing hid...

Страница 28: ...s use DIFU 13 5 8 Entry of Differential Contact Down C 101 ENT Click This entry method is available only for CS CJ and CV series PLCs For the other series PLCs use DIFD 14 Click Down Installation to S...

Страница 29: ...ENT R 5 10 Entry of Vertical Down C 200 ENT ENT ENT Coil 3 O 300 ENT Ctrl Or V Installation to Startup Installation to Startup Opening a new project Opening a new project Device type settings Device...

Страница 30: ...g d0 Products ENT Enter an instruction and its operand Enter a comment See the next page for the contents of instructions Installation to Startup Installation to Startup Opening a new project Opening...

Страница 31: ...s per function shows up Find Instruction Function PLCs supporting the applicable instruction are listed 5 12 Entry of Advanced Instructions 1 Useful Functions Installation to Startup Installation to S...

Страница 32: ...Pulse Bit Show the New Contact dialog Click Select P_1s from the pull down menu Installation to Startup Installation to Startup Opening a new project Opening a new project Device type settings Device...

Страница 33: ...t mark before instructions It makes the instructions differential Attach at mark before instructions It makes the instructions differential Enter a comment if necessary ENT R Refer to the former pages...

Страница 34: ...Entry of comments is omitted here Refer to the section 5 6 to enter annotations Refer to the section 5 6 to enter annotations Installation to Startup Installation to Startup Opening a new project Open...

Страница 35: ...ed Fun No is displayed ENT R Refer to the section 5 4 to enter a rung comment Note The Fun No of MOV depends on PLC types CS series 021 CJ series 021 CV series 030 C series 21 Note The Fun No of MOV d...

Страница 36: ...enter rungs and comments ENT ENT T0 T0 Indicates TIM0 Enter a comment Timer 1 Entry of a Timer bit Entry of a Timer instruction I TIM 0 30 ENT R Installation to Startup Installation to Startup Opening...

Страница 37: ...0 5 ENT R Move the cursor by using arrow keys or a mouse Enter a bit for reset C ENT R 402 O ENT Entry of a Counter instruction Entry of a Counter bit ENT ENT Installation to Startup Installation to...

Страница 38: ...change the bit numbers When making a mistake press or Ctrl Z for Undo return to the previous operation press or Ctrl Y for Redo go to the next operation Installation to Startup Installation to Startu...

Страница 39: ......

Страница 40: ...on Output Window Double click a displayed error and the cursor in Ladder Diagram will go to the corresponding error location and the error rung will be shown in red Double click a displayed error and...

Страница 41: ...o online with CX Simulator with one button You need to install CX Simulator Online with Simulator Enables you to go online with CX Simulator with one button You need to install CX Simulator This time...

Страница 42: ...ode Click Yes If your program has a large volume of data the scroll speed of the screen may become slow when monitoring In that case click the below icon to cancel monitoring once scroll the screen to...

Страница 43: ...utton pressed The screen is divided into two panes up and down and you can display any address in two panes respectively by using the scroll bars The screen is divided into two panes up and down and y...

Страница 44: ...ce On Force Off Program Check Program Check Online Edit Online Edit Entry of BOOL type contact Entry of BOOL type contact Example Entry of 4CH 00Bit Or enter 400 without a period in the Name or addres...

Страница 45: ...ed by the word Double click the mouse The present values of bits and words are changed in Watch Window An entry dialog opens Enter a new value that you want to change to Click 4 word data is displayed...

Страница 46: ...s set by this operation are all saved when the project is saved extension opt Therefore they are loaded as well as data such as ladder programs when the project is loaded next time The names set by th...

Страница 47: ...operands of advanced instructions is pasted on Watch Window Moreover the on off statuses of the bits and the present values of words are displayed Data such as rungs bits per block or operands of adva...

Страница 48: ...when displayed Select View Show in RungWrap The rung is wrapped at the right bus bar Once set this function is always active until released by taking the reverse procedure of the above one Online to...

Страница 49: ...fferential Monitor from the popup menu Move the cursor to a bit to be monitored Click Start The count number is displayed on the dialog every time the differential condition differential up in this ex...

Страница 50: ...lick the Address tab Double click Forced Status Online to Transfer Online to Transfer Monitoring Monitoring Force On Force Off Force On Force Off Program Check Program Check Online Edit Online Edit Fo...

Страница 51: ...running in the Monitor mode only Move the cursor to the set value of a timer Enter the new set value 100 Click OK to complete 15 Changing Present Value of Timer Move the cursor to the present value of...

Страница 52: ...rence Tool Click The found bits are listed The found bits are listed 3 Enter a bit number that you want to find in the Address field Enter a bit number that you want to find in the Address field 1 You...

Страница 53: ...s not turned on Therefore the function retraces rungs to find the coil 2 00 2 Move the cursor to the following position contact 2 00 and press the Space key Space 3 The reason why the coil 2 00 is not...

Страница 54: ...ce 6 The focus moves to the coil 1 01 As it turned out the cause was the contact 0 01 that was not turned on Press the Space key to jump from a coil to a contact having the same address as the coil or...

Страница 55: ...from the pull down menu PLC To find a target from all tasks programs Current view To find from a section or task program being edited Click an icon in Project Workspace to select a task Scope of Find...

Страница 56: ...f rung comments on the screen and moves the cursor to the position where a selected rung comment is used in the ladder Rung comments improve the efficiency of debug or maintenance of rungs divided int...

Страница 57: ...period between a channel and a bit is unnecessary Click the How to Input button and the Help of Find and Replace Examples will be displayed Set the scope of Find Current view Click Report Click OK Ou...

Страница 58: ...Edit 21 Online Edit 1 Move the cursor to a rung you want to modify 2 Select Program Online Edit Begin from the CX Programmer menu 3 Enter a bit number 4 11 in this example you want to edit to 4 Selec...

Страница 59: ...ay of output instructions Useful Functions Vertical display of output instructions Tools T Options O Check the Show output instructions horizontally Z box Check the Show output instructions horizontal...

Страница 60: ......

Отзывы: