background image

3

CJ1W-NC

@@

4

Connecting Cables

Applicable Units

Applicable Servo Drive

Number of

control axes

Cable

Length

Model

 Output Type

Model

Name

Model

Open-collector 
output

CJ1W-NC

@

14

OMNUC G/G5 Series

R88D-GT/-KT

1 axis

1m

XW2Z-100J-G13

3m

XW2Z-300J-G13

SMARTSTEP2

R7D-BP

1m

XW2Z-100J-G16

3m

XW2Z-300J-G16

OMNUC G/G5 Series

R88D-GT/-KT

2 axes

1m

XW2Z-100J-G5

3m

XW2Z-300J-G5

SMARTSTEP2

R7D-BP

1m

XW2Z-100J-G8

3m

XW2Z-300J-G8

Line-driver output

CJ1W-NC

@

34

OMNUC G/G5 Series

R88D-GT/-KT

1 axis

1m

XW2Z-100J-G9

5m

XW2Z-500J-G9

10m

XW2Z-10MJ-G9

SMARTSTEP2

R7D-BP

1m

XW2Z-100J-G12

5m

XW2Z-500J-G12

10m

XW2Z-10MJ-G12

OMNUC G/G5 Series

R88D-GT/-KT

2 axes

1m

XW2Z-100J-G1

5m

XW2Z-500J-G1

10m

XW2Z-10MJ-G1

SMARTSTEP2

R7D-BP

1m

XW2Z-100J-G4

5m

XW2Z-500J-G4

10m

XW2Z-10MJ-G4

Содержание CJ1W-NC214 -

Страница 1: ...d G5 series Servomotors are supported enabling an absolute positioning system This eliminates the need to redefine the origin after power interruptions helping to provide extra added value Select from direct operation or memory operation Up to 500 positioning sequences can be saved as the data for memory operation for each axis Any of three end patterns independent automatic or consecutive can be ...

Страница 2: ... CJ1 Special I O Units Position Control Units High Speed type Pulse train open collector output with Pulse Counter Function 2 axes 2 0 27 CJ1W NC214 UC1 CE 4 axes 0 31 CJ1W NC414 Pulse train line driver output with Pulse Counter Function 2 axes 2 0 27 CJ1W NC234 4 axes 0 31 CJ1W NC434 Product name Specifications Model Standards Number of licenses Media FA Integrated Tool Package CX One Ver 4 The C...

Страница 3: ... G16 3m XW2Z 300J G16 OMNUC G G5 Series R88D GT KT 2 axes 1m XW2Z 100J G5 3m XW2Z 300J G5 SMARTSTEP2 R7D BP 1m XW2Z 100J G8 3m XW2Z 300J G8 Line driver output CJ1W NC 34 OMNUC G G5 Series R88D GT KT 1 axis 1m XW2Z 100J G9 5m XW2Z 500J G9 10m XW2Z 10MJ G9 SMARTSTEP2 R7D BP 1m XW2Z 100J G12 5m XW2Z 500J G12 10m XW2Z 10MJ G12 OMNUC G G5 Series R88D GT KT 2 axes 1m XW2Z 100J G1 5m XW2Z 500J G1 10m XW2...

Страница 4: ...Z 200X Cable length 3 0m XW2Z 300X Cable length 5 0m XW2Z 500X Cable length 10 0m XW2Z 010X Connector Terminal Block 20 points M2 4 screw terminal XW2B 20G4 20 points M3 5 screw terminal XW2B 20G5 20 points M3 screw terminal XW2D 20G6 Name Specifications Model Connector Socket For a 50 pin MIL plug crimp socket connector For AWG24 XG5M 5032 N Connector Cover For a 50 pin MIL plug crimp socket conn...

Страница 5: ...14 234 414 434 Not supported 5 Units 5 Units per Expansion Backplane Not Supported Not Supported 5 Units CPU Unit Functions Required Programming Device CX Programmer Programming Console Ver 7 1 or lower Ver 8 0 Ver 8 02 or higher CJ1W NC 4 Unit Ver 1 0 Functions for unit version 1 0 Not supported Not supported Supported Not supported 1 Move Absolute 14 Manual Pulses Output 2 Unlimited Move Absolut...

Страница 6: ...Phase difference pulse output forward reverse direction pulse output pulse direction output Controls Control method Open loop control by pulse train output Number of controlled axes 2 axes 4 axes Units of control Pulse mm inch degree Positioning functions Memory operation direct operation Independent operation Independent 2 axes Independent 4 axes Linear interpolation 2 axes maximum 4 axes maximum...

Страница 7: ...onstant speed Inching operation The axis inches in the forward reverse direction MPG operation Connect a manual pulsar and perform manual feed Auxiliary control function Command unit setting You can set a desired unit of control for each axis according to the machine Acceleration deceleration control Auto acceleration deceleration control This function automatically generates an acceleration decel...

Страница 8: ...Lit ON Phase A B input status of the Axis 1 feedback counter ON when lit OFF when unlit Unlit OFF A2 B2 Orange Lit ON Phase A B input status of the Axis 2 feedback counter ON when lit OFF when unlit Unlit OFF A3 B3 Orange Lit ON Phase A B input status of the Axis 3 feedback counter ON when lit OFF when unlit Unlit OFF A4 B4 Orange Lit ON Phase A B input status of the Axis 4 feedback counter ON whe...

Страница 9: ...007 Configuration Diagram for IDC Connector for Discrete Wires Connector type Model Flat cable connector XG4M 5030 T 1 IDC connector for discrete wires Socket XG5M 5032 N 2 XG5M 5035 N 3 Hood cover XG5S 5022 horizontal Socket Wires IDC tool Connection complete Hood cover Usage type Double rows with polarity guide locking possible Discrete wires Double rows Simple IDC tool XY2B 7006 Horizontal type...

Страница 10: ...its Operation Manual Provides information on operating and installing Position Control Units including details on basic settings memory operation direct operation from CPU and other functions W446 SBCA 337 CXONE AL C V AL D V CX Programmer Operation Manual Describes operating procedures for the CX Programmer Also refer to the Software User s Manual W473 and Instructions Reference Manual W474 when ...

Страница 11: ... products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this catalog Nuclear energy control systems combustion systems railroad systems aviation systems medical equipment amusement machines vehicles safety equipment and installations subject to separate industry or government regulations Systems machines and equipment ...

Отзывы: