Omron CJ1W-NC214 - Скачать руководство пользователя страница 11

Read and Understand This Catalog 

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or 
comments. 
 

Warranty and Limitations of Liability 

 
WARRANTY 

OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) 
from date of sale by OMRON. 
 
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR 
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS.    ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS 
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.    OMRON DISCLAIMS ALL OTHER 
WARRANTIES, EXPRESS OR IMPLIED. 

 

LIMITATIONS OF LIABILITY 

OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS 
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT 
LIABILITY. 
 
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. 
 
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS 
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT 
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. 

 

 

Application Considerations 

 
SUITABILITY FOR USE 

OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's 
application or use of the products.   
     
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the 
products.    This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, 
machine, system, or other application or use. 
 
The following are some examples of applications for which particular attention must be given.    This is not intended to be an exhaustive list of all possible 
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: 
 

  Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. 

 

  Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, 

safety equipment, and installations subject to separate industry or government regulations. 

 

  Systems, machines, and equipment that could present a risk to life or property.     

 
Please know and observe all prohibitions of use applicable to the products. 
 
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE 
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND 
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. 

 

PROGRAMMABLE PRODUCTS 

OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. 

 

 

Disclaimers 

 
CHANGE IN SPECIFICATIONS 

Product specifications and accessories may be changed at any time based on improvements and other reasons. 
 
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.   
However, some specifications of the products may be changed without any notice.    When in doubt, special model numbers may be assigned to fix or 
establish key specifications for your application on your request.    Please consult with your OMRON representative at any time to confirm actual 
specifications of purchased products. 
 

DIMENSIONS AND WEIGHTS 

Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. 

 

PERFORMANCE DATA 

Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the 

result of OMRON’s test conditions, and the users must correlate it to actual application requirements. 

Actual performance is subject to the OMRON 

Warranty and Limitations of Liability. 

 

ERRORS AND OMISSIONS 

The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, 
typographical, or proofreading errors, or omissions. 

 

 

 

2012.10 

In the interest of product improvement, specifications are subject to change without notice. 

OMRON Corporation 

Industrial Automation Company 

 

http://www.ia.omron.com/ 

(c)Copyright OMRON Corporation 2012 All Right Reserved. 

Содержание CJ1W-NC214 -

Страница 1: ...d G5 series Servomotors are supported enabling an absolute positioning system This eliminates the need to redefine the origin after power interruptions helping to provide extra added value Select from direct operation or memory operation Up to 500 positioning sequences can be saved as the data for memory operation for each axis Any of three end patterns independent automatic or consecutive can be ...

Страница 2: ... CJ1 Special I O Units Position Control Units High Speed type Pulse train open collector output with Pulse Counter Function 2 axes 2 0 27 CJ1W NC214 UC1 CE 4 axes 0 31 CJ1W NC414 Pulse train line driver output with Pulse Counter Function 2 axes 2 0 27 CJ1W NC234 4 axes 0 31 CJ1W NC434 Product name Specifications Model Standards Number of licenses Media FA Integrated Tool Package CX One Ver 4 The C...

Страница 3: ... G16 3m XW2Z 300J G16 OMNUC G G5 Series R88D GT KT 2 axes 1m XW2Z 100J G5 3m XW2Z 300J G5 SMARTSTEP2 R7D BP 1m XW2Z 100J G8 3m XW2Z 300J G8 Line driver output CJ1W NC 34 OMNUC G G5 Series R88D GT KT 1 axis 1m XW2Z 100J G9 5m XW2Z 500J G9 10m XW2Z 10MJ G9 SMARTSTEP2 R7D BP 1m XW2Z 100J G12 5m XW2Z 500J G12 10m XW2Z 10MJ G12 OMNUC G G5 Series R88D GT KT 2 axes 1m XW2Z 100J G1 5m XW2Z 500J G1 10m XW2...

Страница 4: ...Z 200X Cable length 3 0m XW2Z 300X Cable length 5 0m XW2Z 500X Cable length 10 0m XW2Z 010X Connector Terminal Block 20 points M2 4 screw terminal XW2B 20G4 20 points M3 5 screw terminal XW2B 20G5 20 points M3 screw terminal XW2D 20G6 Name Specifications Model Connector Socket For a 50 pin MIL plug crimp socket connector For AWG24 XG5M 5032 N Connector Cover For a 50 pin MIL plug crimp socket conn...

Страница 5: ...14 234 414 434 Not supported 5 Units 5 Units per Expansion Backplane Not Supported Not Supported 5 Units CPU Unit Functions Required Programming Device CX Programmer Programming Console Ver 7 1 or lower Ver 8 0 Ver 8 02 or higher CJ1W NC 4 Unit Ver 1 0 Functions for unit version 1 0 Not supported Not supported Supported Not supported 1 Move Absolute 14 Manual Pulses Output 2 Unlimited Move Absolut...

Страница 6: ...Phase difference pulse output forward reverse direction pulse output pulse direction output Controls Control method Open loop control by pulse train output Number of controlled axes 2 axes 4 axes Units of control Pulse mm inch degree Positioning functions Memory operation direct operation Independent operation Independent 2 axes Independent 4 axes Linear interpolation 2 axes maximum 4 axes maximum...

Страница 7: ...onstant speed Inching operation The axis inches in the forward reverse direction MPG operation Connect a manual pulsar and perform manual feed Auxiliary control function Command unit setting You can set a desired unit of control for each axis according to the machine Acceleration deceleration control Auto acceleration deceleration control This function automatically generates an acceleration decel...

Страница 8: ...Lit ON Phase A B input status of the Axis 1 feedback counter ON when lit OFF when unlit Unlit OFF A2 B2 Orange Lit ON Phase A B input status of the Axis 2 feedback counter ON when lit OFF when unlit Unlit OFF A3 B3 Orange Lit ON Phase A B input status of the Axis 3 feedback counter ON when lit OFF when unlit Unlit OFF A4 B4 Orange Lit ON Phase A B input status of the Axis 4 feedback counter ON whe...

Страница 9: ...007 Configuration Diagram for IDC Connector for Discrete Wires Connector type Model Flat cable connector XG4M 5030 T 1 IDC connector for discrete wires Socket XG5M 5032 N 2 XG5M 5035 N 3 Hood cover XG5S 5022 horizontal Socket Wires IDC tool Connection complete Hood cover Usage type Double rows with polarity guide locking possible Discrete wires Double rows Simple IDC tool XY2B 7006 Horizontal type...

Страница 10: ...its Operation Manual Provides information on operating and installing Position Control Units including details on basic settings memory operation direct operation from CPU and other functions W446 SBCA 337 CXONE AL C V AL D V CX Programmer Operation Manual Describes operating procedures for the CX Programmer Also refer to the Software User s Manual W473 and Instructions Reference Manual W474 when ...

Страница 11: ... products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this catalog Nuclear energy control systems combustion systems railroad systems aviation systems medical equipment amusement machines vehicles safety equipment and installations subject to separate industry or government regulations Systems machines and equipment ...

Отзывы: