Double-precision Floating-point Instructions (CS1-H, CJ1-H, CJ1M, or CS1D Only)
Section 3-16
Description
The input comparison instruction compares the data specified in S
1
and S
2
as
double-precision floating point values (64-bit IEEE754 data) and creates an
ON execution condition when the comparison condition is true. When the data
is stored in words, S
1
and S
2
specify the first of four words containing the 64-
bit data. The 64-bit floating-point data cannot be input as constants.
Inputting the Instructions
The input comparison instructions are treated just like the LD, AND, and OR
instructions to control the execution of subsequent instructions.
Indirect DM/EM
addresses in BCD
*D00000 to *D32767
*E00000 to *E32767
*En_00000 to *En_32767
(n = 0 to C)
Constants
---
Data Registers
---
Index Registers
---
Indirect addressing
using Index Registers
,IR0 to ,IR15
–2048 to +2047 ,IR0 to –2048 to +2047 ,IR15
DR0 to DR15, IR0 to IR15
,IR0+(++) to ,IR15+(++)
,–(– –)IR0 to, –(– –)IR15
Area
S
1
S
2
Input type
Operation
LD
The instruction can be connected directly to the left bus bar.
AND
The instruction cannot be connected directly to the left bus bar.
OR
The instruction can be connected directly to the left bus bar.
LD connection
AND connection
OR connection
ON execution condition when
comparison result is true.
ON execution condition when
comparison result is true.
ON execution condition when
comparison result is true.
<D
<D
<D
Содержание CJ1G-CPUxx
Страница 3: ...iv N o t i c e ...
Страница 5: ...vi ...
Страница 21: ...xxii Conformance to EC Directives 6 ...
Страница 35: ......
Страница 1131: ...1110 CJ series Instruction Execution Times and Number of Steps Section 4 2 ...
Страница 1143: ...Authorized Distributor Cat No W340 E1 08 Note Specifications subject to change without notice Printed in Japan ...