Double-precision Floating-point Instructions (CS1-H, CJ1-H, CJ1M, or CS1D Only)
Section 3-16
Description
RADD(849) converts the double-precision (64-bit) floating-point number in
words S to S+3 from degrees to radians and places the result in words D to
D+3. (The floating point source data must be in IEEE754 format.)
Degrees are converted to radians by means of the following formula:
Degrees
×
π
/180 = radians
If the absolute value of the result is greater than the maximum value that can
be expressed as floating-point data, the Overflow Flag will turn ON and the
result will be output as
±∞
.
If the absolute value of the result is less than the minimum value that can be
expressed as floating-point data, the Underflow Flag will turn ON and the
result will be output as 0.
Flags
EM Area with bank
En_00000 to En_32764
(n = 0 to C)
Indirect DM/EM
addresses in binary
@ D00000 to @ D32767
@ E00000 to @ E32767
@ En_00000 to @ En_32767
(n = 0 to C)
Indirect DM/EM
addresses in BCD
*D00000 to *D32767
*E00000 to *E32767
*En_00000 to *En_32767
(n = 0 to C)
Constants
---
Data Registers
---
Index Registers
---
Indirect addressing
using Index Registers
,IR0 to ,IR15
–2048 to +2047 ,IR0 to –2048 to +2047 ,IR15
DR0 to DR15, IR0 to IR15
,IR0+(++) to ,IR15+(++)
,–(– –)IR0 to, –(– –)IR15
Area
S
D
S+1CH
D+1CH
SCH
DCH
S+2CH
D+2CH
S+3CH
D+3CH
Result (radians, 64-bit floating-point data)
Source (degrees, 64-bit floating-point data)
Name
Label
Operation
Error Flag
ER
ON if the source data is not recognized as floating-point
data.
ON if the source data is not a number (NaN).
OFF in all other cases.
Equals Flag
=
ON if both the exponent and mantissa of the result are 0.
OFF in all other cases.
Overflow Flag
OF
ON if the absolute value of the result is too large to be
expressed as a double-precision floating-point value.
Underflow Flag
UF
ON if the absolute value of the result is too small to be
expressed as a double-precision floating-point value.
Negative Flag
N
ON if the result is negative.
OFF in all other cases.
Содержание CJ1G-CPUxx