1. Wiring
Note 1: Connect single-phase 200 V AC to terminals R/L1 and S/L2 of the J7AZB
Note 2: The braking resistor cannot be connected because no braking transistor is incorporated.
SHORT BAR
U/T1
V/T2
W/T3
M
+1
+2
-
Noise Filter
L1
L2
L3
L1i
L2i
L3i
3-phase 200 V AC
single-phase 200 V AC
(see note 1)
R/L1
S/L2
T/L3
3G3JV PFI
@
Multi-function input 1 (S2)
Multi-function input 2 (S3)
Multi-function input 3 (S4)
Multi-function input 4 (S5)
Sequence input common
Forward/Stop
S1
S2
S3
S4
S5
SC
FC
FR
FS
Frequency reference power
supply 20mA at +12V
External frequency
adjuster
(2 k
Ω
1/4 W min.)
Frequency reference input
Frequency reference common
Multi-function contact output
NO
NC
Common
Analog monitor output
MA
MB
MC
AM
AC
Analogue monitor output
common
Main circuit input
terminals
Control circuit
terminals
Ground
terminal
Ground terminal
Main circuit
output terminals
Arrangement of Control Circuit Terminals