manualshive.com logo in svg
background image

19

USING THE MEMORY FUNCTION

The monitor is designed to store the blood pressure and the pulse rate in the memory 
for two people (USER A and USER B) every time a measurement is completed. The 
monitor automatically stores up to 30 sets of measurement values (blood pressure and 
pulse rate) for each user (A and B). When 30 sets of measurement values are stored, the 
oldest record is deleted to save the most recent values.

AVERAGING FUNCTION

The monitor calculates the average reading based on the three most recent sets of 
measurement values taken within 10 minutes of the most recent reading.

NOTE:

 If two sets of measurement values are stored in the memory for the 10 minutes 

period, the average is based on the two sets of measurement values. If one set 
of measurement values is stored, this is displayed as the average.

TO DISPLAY THE MEASUREMENT VALUES

1.  Press the START/STOP button to turn the monitor on.
2.  Select your USER ID (A or B).
3.   Press the Up or Down button ( 

 / 

 ). The Average Value Symbol ( 

 ) 

appears on the display when the average reading is shown.

4.  Press the Up or Down button  ( 

 / 

 ) to display the sets of measurement 

values.

 
 

Press the Down button ( 

 ) repeatedly

 Average 

value 

 most recent set of measurement values 

 the older readings 

 

back to the average value

 

Press the Up button ( 

 ) repeatedly

 Average 

value 

 oldest set of measurement values 

 the more recent readings 

 

back to the average value

Содержание BP742CAN

Страница 1: ...ENGLISH 5 series Blood Pressure Monitor Model BP742CAN INSTRUCTION MANUAL...

Страница 2: ...ension Indicator 9 Using the Memory Function 10 Battery Installation 11 Battery Replacement 12 Setting the Date and Time 13 Applying the Arm Cuff 15 Applying the Cuff on the Left Arm 15 Applying the C...

Страница 3: ...mes with the following components Monitor Standard Adult Arm Cuff 4 AA Alkaline Batteries Instruction Manual printed in English and French Quick Start Guide The BP742CAN 5 series Automatic Blood Press...

Страница 4: ...tially hazardous situation which if not avoided may result in minor or moderate injury to the user or patient or damage to the equipment or other property OPERATING THE DEVICE Contact your physician f...

Страница 5: ...able local regulations Unlawful disposal may cause environmental pollution Do not use a cellular phone near the device It may result in an operational failure Use only Omron authorized parts and acces...

Страница 6: ...your left arm on table so that the cuff is at the same level as your heart 6 Remain still and do not talk during the measurement 7 Wait 2 3 minutes between measurements The wait time allows the arter...

Страница 7: ...Components Quick Start Guide Instruction Manual Standard Adult Arm Cuff Date Time setting button Air Jack Air plug Air tube Display AC adapter Jack Battery compartment Up Down buttons USER ID Selectio...

Страница 8: ...ion symbol Pulse display Heartbeat symbol Hypertension Indicator Date Time Display Irregular Heartbeat symbol Movement error symbol Average Value symbol Memory symbol Displayed when viewing values sto...

Страница 9: ...rror Symbol is displayed if you move your body during the measurement Please remove the arm cuff and wait 2 3 minutes Reapply the arm cuff and take another measurement AVERAGE VALUE SYMBOL The Average...

Страница 10: ...eline because blood pressure depends on age and morbidity The CHS recommends a lower home blood pressure goal for certain patients including people with diabetes or kidney disease1 WARNING The monitor...

Страница 11: ...th this device 1 Press the indicator on the battery cover and slide the cover off in the direction of the arrow 2 Install 4 AA size batteries so the positive and negative polarities match the polariti...

Страница 12: ...Turn the unit off before replacing the batteries If the batteries are removed while the unit is still on the date and time will be reset to that of the previous use However the measurement results ar...

Страница 13: ...Date Time Setting button to adjust the date and time The year flashes on the display 2 SETTING THE YEAR The year can be set between 2010 and 2040 When the display reaches 2040 it will return to 2010...

Страница 14: ...n the display 5 SETTING THE HOUR The time is set using AM or PM Press the Up button to advance by one hour Press the Date Time Setting button to set the current hour The minute flashes on the display...

Страница 15: ...ING THE CUFF ON THE LEFT ARM 1 Make sure the air plug is securely inserted in the main unit 2 Remove tight fitting clothing from your upper arm 3 Apply the cuff to your left upper arm so the arrow is...

Страница 16: ...p 3 Apply the cuff to your right upper arm so the arrow and the air tube runs along the inside of your arm The bottom of the cuff should be approximately 1 2 above your elbow NOTE Be careful not to re...

Страница 17: ...ill and do not talk during measurement 4 Press the START STOP button The cuff starts to inflate automatically As the cuff inflates the monitor automatically determines your ideal inflation level Remai...

Страница 18: ...onitor will automatically turn off after five minutes SPECIAL CONDITIONS CAUTION Inflating to a higher pressure than necessary may result in bruising where the cuff is applied If your systolic pressur...

Страница 19: ...NOTE If two sets of measurement values are stored in the memory for the 10 minutes period the average is based on the two sets of measurement values If one set of measurement values is stored this is...

Страница 20: ...es faster TO DELETE ALL VALUES STORED IN THE MEMORY The values stored in the memory are deleted by USER ID You cannot partially delete values stored in the memory All values for the user you select wi...

Страница 21: ...t sunlight CAUTION Store the device and the components in a clean safe location CAUTION Do not subject the monitor to strong shocks such as dropping the unit on the floor Remove the batteries if the u...

Страница 22: ...3 minutes Take another measurement Cuff over inflated Device error Contact Customer Service Movement during measurement Keep still and take another measurement Irregular or weak pulses are detected R...

Страница 23: ...ones Check the battery installation for proper placement of the battery polarities Measurement values appear too high or too low Blood pressure varies constantly Many factors including stress time of...

Страница 24: ...y one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the product and the receiver Connect the product into an outlet on a circuit differen...

Страница 25: ...d handling fee Enclose the Proof of Purchase Include a letter with your name address phone number and description of the specific problem Pack the product carefully to prevent damage in transit Becaus...

Страница 26: ...ty 50 F to 104 F 10 C to 40 C 15 to 90 RH Storage Temperature Humidity Air Pressure 4 F to 140 F 20 C to 60 C 10 to 95 RH 700 1060 hPa Main Unit Weight Approximately 12 oz 340g not including batteries...

Страница 27: ...Omron Healthcare Inc 1200 Lakeside Drive Bannockburn IL 60015 www omronhealthcare ca Copyright 2010 Omron Healthcare Inc Made in China 5330254 2A...

Отзывы: