A3C
8
Approved Standard Ratings
UL (File No. E41515), CSA (File No. LR45258)
Standard Load:
0.5 A at 250 VAC
1 A at 125 VAC
1 A at 30 VDC
Microload:
0.1 A at 125 VAC
0.1 A at 30 VDC
Note: Certification has been obtained for the Switch Unit.
For detailed information on individual products that have received
certification, consult your supplier.
CCC (GB14048.5)
Standard Load:
0.5 A at 250 VAC
Microload:
0.1 A at 250 VAC
Ratings
Note: The above ratings are for testing under the following conditions:
1) Load: Resistive load
2) Mounting conditions: No vibrations or shock
3) Temperature: 20
°
C
±
2
°
C
4) Operation frequency: 20 operations/minute
* The minimum permissible load is 1 mA, 5 VDC.
LED Lamp
Incandescent Lamp
Characteristics
*1. With alternate-operation models, one operation cycle consists of set and
reset operations.
*2. The figure given above for the dielectric strength between lamp terminals is
for when there is no LED lamp or incandescent lamp mounted.
*3. No malfunction for more than 1s.
Operating Characteristics
* Alternate operation models only.
Contact Form
Model Item
AC resistive load
DC resistive load
Standard load
0.5 A at 250 VAC
1 A at 125 VAC
1 A at 30 VDC
Microload
*
0.1 A at 125 VAC
0.1 A at 30 VDC
Rated voltage
Rated current
Operating
voltage
Internal limiting
resistance
5 VDC
30 mA
5 VDC
±
5%
33
Ω
12 VDC
15 mA
12 VDC
±
5%
270
Ω
24 VDC
10 mA
24 VDC
±
5%
1,600
Ω
Rated voltage
Rated current
Operating voltage
6 VAC/DC
60 mA
5 VAC/DC
14 VAC/DC
40 mA
12 VAC/DC
28 VAC/DC
24 mA
24 VAC/DC
Operat-
ing fre-
quency
Mechanical
Momentary-action models: 120 operations/minute max.
Alternate-action models: 60 operations/minute max.
*
1
Electrical
20 operations/minute max.
Contact
Resis-
tance
Standard load
50m
Ω
max.
Microload
100m
Ω
max.
Insulation resistance
100 M
Ω
min. (at 500 VDC)
Dielectric
strength
Between terminals
of same polarity
1,000 VAC, 50/60 Hz for 1 min
Between terminals
of different polarity
2,000 VAC, 50/60 Hz for 1 min
Between each
terminal and ground
2,000 VAC, 50/60 Hz for 1 min
Between lamp
terminals
1,000 VAC, 50/60 Hz for 1 min
*
2
Vibration
resis-
tance
Malfunction
10 to 55 Hz, 1.5-mm double amplitude
*
3
Shock
resis-
tance
Destruction
500 m/s
2
Malfunction
150 m/s
2
*
3
Durability
Mechanical
Momentary-operation models: 1,000,000 operations min.
Alternate-operation models: 100,000 operations min.
*
1
Electrical
100,000 operations min.
Weight
Approx. 5 g <The weight indicated here applies
to the lighted models (SPST-NO+SPST-NC).>
Ambient operating temperature
−
10
°
C to +55
°
C (with no icing or condensation)
Ambient operating humidity
35% to 85%RH
Ambient storage temperature
−
25
°
C to +65
°
C (with no icing or condensation)
Degree of protection
IP40
Electric shock protection class
Class II
PTI (proof tracking index)
175
Pollution degree
3 (IEC60947-5-1)
Operating force
OF max.
2.45 N {250 gf}
Releasing force
RF min.
0.29 N {30 gf}
Total travel
TT
Approx. 3.5 mm
Lock travel alternate LTA min.
*
0.5 mm
Pretravel
PT max.
2.5 mm
Contact name
Contact form
SPDT
NO
NO
NC
NC