![Omron 3G3MX-A2001 Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/omron/3g3mx-a2001/3g3mx-a2001_migration-giude_742805017.webp)
16
MV MX
Model
Function
No.
Set
value
No.
Set
value
Remarks
Energy saving control
selection
n139 0
―――
―――
Energy saving control
coefficient K2
n140
Varies
with
capacity
―――
―――
Energy saving voltage low
limit at 60Hz output.
n141 50
―――
―――
Energy saving voltage lower
limit at 6Hz output
n142 12
―――
―――
Power average time
n143
1
―――
―――
Probe operation voltage
limit
n144 0
―――
―――
Prove operation control
voltage step at 100%.
n145 0.5
―――
―――
Prove operation control
voltage step at 5%
n146 0.2
―――
―――
Not used
n147
n148
―――
―――
―――
Pulse train input scale
n149
2500
―――
―――
Multi function analog output
pulse train frequency
selection
n150 0
―――
―――
RS-422/485
communication time over
detection selection
n151 0
C076
C077
02
0.00
∗
C076:Select stop operation at time out
∗
C077:Set the time of communication time
out
RS-422/485
communications frequency
reference/ monitor unit
selection
n152
0
―――
―――
RS-422/485
communications
Slave address
n153 00 C072 1
RS-422/485
communications
Baud rate select
n154 2 C071 04
RS-422/485
communications
Parity select
n155 0 C074 00
RS-422/485
communications
Send dwell
n156 10 C078 0
RS-422/485
communications
RTS control enabled/
disabled
n157 0
―――
―――
Содержание 3G3MX-A2001
Страница 1: ...1 3G3MV 3G3MX Migration guide...