13
MV MX
Model
Function
No.
Set
value
No.
Set
value
Remarks
Multi function analog current
input filter time constant
n073 0.10
―――
―――
Pulse train frequency
reference gain
n074 100
―――
―――
Pulse train frequency
reference bias
n075 0
―――
―――
Pulse train frequency
reference input filter time
constant
n076 0.10
―――
―――
Multi function analog input
terminal function selection
n077 0
―――
―――
Multi function analog input
terminal selection
n078 0
―――
―――
Multi function analog input
frequency bias value
n079 10
―――
―――
Carrier frequency
n080
Varies
with
capacity
b083 5.0
Operation after momentary
power interruption and
return selection
n081 0
Number of fault retries
n082
0
b001 to
b005
―――
Set b001=1or 2.
Execute error retry to over voltage
and over current at b005=0.
The numbers of retry is fixed at 3.
Jump frequency 1
n083
0.00
A063
0.0
Jump frequency 2
n084
0.00
A065
0.0
Jump frequency 3
n085
0.00
A067
0.0
Jump width
n086
0.00
A064
A066
A068
0.5
MV:
set output frequency for jump as
n083
to 085 and set jump width to n086.
MX: set frequency command for jump as
A063
・
065
・
067. Set jump frequency width
on A064
・
066
・
068.
Accumulated operating
time select
n087 0
―――
―――
Accumulated operating time
n088
0
d016
d017
―――
MV
:
select monitoring time on n087 and
n088 displays cumulative operation time.
MX:d016:accumulated operation on RUN
d017:Power ON time
DC injection breaking
current
n089 50 A054 50
DC injection
breaking-to-stop time
n090 0.5 A055 0.5
DC injection breaking time
at startup
n091 0.0
―――
―――
Stall prevention during
deceleration select
n092 0 b130 00
MX:
set level on b131.
Stall prevention operation
level during deceleration
n093 170 b140 00
MX:ON/OFF setting only
Detection level is 160% fixed