14
MV MX
Model
Function
No.
Set
value
No.
Set
value
Remarks
Stall prevention
operation level
n094 160
―――
―――
Frequency detection level
n095
0.00
C042
C043
0.0
0.0
C042:at acceleration C043:at deceleration
Over-torque detection
function level 1
n096 0
―――
―――
Over-torque detection
function level2
n097 0
―――
―――
Over-torque detection level
n098
160
C041
Rated
current
Over-torque detection time
n099
0.1
―――
―――
Up/down frequency memory n100
0
C101
00
Speed search
deceleration time
n101 2.0
―――
―――
Speed search
operation level
n102 150
―――
―――
Replaceable with starting at same
frequency on trip retry function.
Torque compensation gain
n103
1.0
A046
1.0
Torque compensation
primary delay time constant
n104 0.3
―――
―――
Torque compensation
excitation loss
n105
Varies
with
capacity
―――
―――
Rated motor slip
n106
Varies
with
capacity
H006 100
Motor phase-to-phase
resistance
n107
Varies
with
capacity
―――
―――
Motor leakage
Inductance
n108
Varies
with
capacity
―――
―――
Torque compensation limit
n109
150
―――
―――
Motor no load current
n110
Varies
with
capacity
―――
―――
Slip compensation gain
n111
0.0
Slip compensation
Primary delay time constant
n112 2.0
A047
H006
100
100
Slip compensation select on
regeneration operation
n113 0
―――
―――
(Not used)
n114
―――
―――
―――
Stall prevention operation
level automatic gradual
decrease function selection
n115 0
―――
―――
Содержание 3G3MX-A2001
Страница 1: ...1 3G3MV 3G3MX Migration guide...