00033011.DOC
16/19
■
Attack control
This control determines the rate by which the compressor
responds to the signal which exceeds the threshold. This
control can be adjusted from 0.1 ms to 100 ms. Use short
Attack times for percussion and slower times soft
inaudible compression.
■
Release control
This control determines the rate that the compressor
returns to unity again after falling below the threshold
level. This control can be adjusted from 0.1 to 2.5
seconds. Use short times for fast recovery and maximum
output and use longer times to avoid pumping. The
diagram below shows how the ATTACK/RELEASE
works. Different time settings will create different effects.
set the LEVEL control to add the same amount of
gain that is shown on the GAIN REDUCTION
meter. For example, if the average amount of gain
reduction shown on the meter is 10 dB, then setting
the LEVEL control to 10 dB will compensate for the
10 dB average level reduction at the output.
■
Output Level LED meter
Lets you keep an eye on the signal level in order to avoid
distortion. Reduce the level if CLIP lights up permanently.
Peak Stop section
Independent of all other controls, the peak stop enables
you to limit the maximum peak level on the
CL-266
‘s
output. Thus you can protect subsequent units against
signal peaks, short-time overload and excess modulation.
■
Threshold control
This control determines the maximum peak level of the
output signal. The peak stop is capable of limiting signal
peaks without audible distortion.
■
Limit LED
Lights up as soon as the Peak Stop function is active.
■
Bypass selector
This switch allows instant comparison of the original
sound with the equalized sound. Note that the bypass
mode works independently for each channel, even if the
unit is stereo-coupled (via the STEREO/ LINK button).
■
Stereo/Link button
This button toggles the unit between stereo and dual
mono operation. Press the Stereo/Link button IN for
stereo operation where CH A becomes the master
controller for both channels. All of CH B’s controls,
buttons and LEDs will be disabled (except for CH B’s
BYPASS button and GAIN REDUCTION LEDs), as CH B
is the „slave“. With the Stereo/Link button OUT, the unit
works as two separate mono processors, each with its
own independent controls.
Example: INPUT LEVEL 10 dB at 4 dB compression
■
Level control
To adjust the channel or overall output level. Adjust this
control to vary the amount of fixed gain in the
CL-266
‘s
output amplifier stage. This control is especially useful to
compensate for RMS level decrease which results from
the unit’s dynamic processing effects. After you adjust the
CL-266
‘s controls for desired amount of compression,
■
Inputs
Balanced 6.3 mm jack and XLR inputs for connecting
audio units units with line level outputs.
■
Outputs
6.3 mm jack and XLR connectors (wired in parallel) for
connecting audio units units unit with line level
■
AC input with fuseholder
Used to plug the supplied power cord in. Only replace the
fuse when the device is disconnected from mains. Only
use fuses of the same rating and power. The correct fuse
value is specified on the rear panel.
Содержание CL-266