Front Panel Layout

Serial Console Port   

To  configure  the  module  using  the  serial  port,  attach  a  DB-9  serial  (RS-232) 

equipped computer with terminal emulation software such as Procomm or Putty 

to the serial port on the module using a RJ-45 to DB-9 serial cable (not included).  

Some computers do not come with DB-9 serial port connectors and may require a 

USB-to-serial port adapter. 
The port is a standard RS-232 asynchronous serial interface.  The serial ports is 

configured for 57,600bps, 1 stop, 8 data, parity none.  The serial adapter cable 

pin-outs are illustrated below.

Standard RJ-45 to DB-9 serial cable pin-out

Reset Button   

A Reset Button is available on the front of the switch to restore the switch to factory 

default values.  Press and hold the reset button for more than 5 seconds to restore 

the switch to factory default values.

Installation Procedure

1) Configure DIP-switches

2) Installing the Module
3) Apply DC Power
4) Connect Cables
5) Verify Operation

Page 6

1) Configure DIP-switches

DIP-switches are located on the top of the module.  The DIP-switches are used to 

configure modes of operation and networking features. 

DIP-switch Bank Locations

The table below provides a description of each DIP-switch position and function.

Switch

Position

Legend

Function

SW1

LEFT

Single Switch

Mode of Operation

RIGHT

Dual Switch

SW2

LEFT

Switch

RIGHT

Directed Switch

SW3

LEFT

Off

Uplink Redundancy

RIGHT

Link Protection

SW4

LEFT

No Return

RIGHT

F1 Return

SW5

LEFT

MAC Learning

MAC Learning Enabled (factory default)

RIGHT

Off

MAC Learning Disabled

SW6

LEFT

Off

Pause Disabled (factory default)

RIGHT

Pause

Pause Enabled

SW7

LEFT

L2CP Tunnel

L2CP Tunnel (factory default)

RIGHT

Discard

L2CP Tunnel Discard

SW8

LEFT

OPT1 Off

Reserved

RIGHT

On

DIP-switch Definitions

SW1 and SW2:  Mode of Operation

The module supports Switch, Directed Switch and Dual Device modes.
The modes are described with MAC learning enabled.  When MAC learning is 

disabled, unicast packets are forwarded to all ports. 

Содержание RuggedNet 10G/Mi

Страница 1: ...tering this product at www omnitron systems com support within ninety 90 days from the date of shipment During the warranty period Omnitron will at its option repair or replace a product which is prov...

Страница 2: ...ck WARNING Hot surface RuggedNet 10G Mi Quick Start Guide Product Overview The RuggedNet 10G Mi is a ruggedized unmanaged industrial Ethernet switch that features two 1 10G uplink ports and four or ei...

Страница 3: ...Installing the Module 3 Apply DC Power 4 Connect Cables 5 Verify Operation Page 6 1 Configure DIP switches DIP switches are located on the top of the module The DIP switches are used to configure mode...

Страница 4: ...e When configured for Dual Device Mode the module is configured as two logically independent Layer 2 switches On models with 4 RJ 45 user ports Port F1 is associated with ports P1 and P2 and Port F2 i...

Страница 5: ...Page 10 Wall Mounting Refer to the Wall Mount Plate user manual 040 08260 301x for the proper installation guidelines The wall mounting height of the module should be less than or equal to 2 meters 6...

Страница 6: ...shown above WARNING Note the wire colors used in making the positive negative and ground connections Use the same color assignment for the connection at the circuit breaker Connect the power wires to...

Страница 7: ...t linked at 2 5G Green three blinks Port linked at 5G Green four blinks Port linked at 10G SFP Uplink Ports LED Indicators LED Indicators RJ 45 User Ports LED Indicators Legend Indicator Description 1...

Страница 8: ...W x D x H 1 5 x 5 5 x 5 5 38 1 mm x 139 7 mm x 139 7 mm Weight 4 RJ 45 Ports 1 70 lb 772 grams 8 RJ 45 Ports 1 77 lb 803 grams Operating Temperature Extended 40 to 75 C Storage 40 to 80 C Humidity 5...

Отзывы: