background image

Page 17

Description

OmniConverter

®

 GHPoEBT/Sx (60/100W BT)

10/100/1000BASE-T with Gigabit Fiber or Copper Uplinks

Unmanaged 6 Port IEEE 802.3bt PoE Ethernet Switch 

Standard Compliances

IEEE 802.3, 

IEEE 802.3af (15.40 watts max), 

IEEE 802.3at (30 watts max)

IEEE 802.3bt (60 and 100 watts max)

Environmental

REACH, RoHS and WEEE

PoE Modes

IEEE Alternate A (Alt A)

4-Pair

Frame Size

Up to 10,240 bytes

Port Types

Copper: 

RJ-45: 10/100/1000BASE-T

Fiber: 

Fixed:  ST, SC, LC 1000BASE-X Fiber 

 

SFP:  10/100/1000BASE-T SGMII Copper 

 Transceiver or 1000BASE-X Fiber  

 Transceiver

Cable Types

Copper:         EIA/TIA 568A/B, Cat 5 UTP and higher
Fiber:             Multimode: 50/125, 62.5/125µm
                      Single-mode: 9/125µm

AC Power Requirements

(Models with AC/DC Adapters)

100 - 240VAC 50/60Hz
3.5A max at 115VAC
2.5A max at 230VAC

DC Power Requirements
(Models with DC Terminals)

60W BT Models:
+46 to +57VDC;  inclusive of  

                            tolerance
4.46A @ 56VDC
2 Pin Terminal (non-isolated)

100W BT Models:
+46 to +57VDC;  inclusive of 

                            tolerance
7.31A @ 56VDC
2 Pin Terminal (non-isolated)

Dimensions (W x D x H)

6.28” x 5.2” x 1.5” (159.5 mm x 132.1 mm x 38.1 mm)

Weight

Module Only:                        

    

1.6 lbs.;   735 grams

Module with AC/DC Adapter:   3.7 lbs.; 1703 grams

Operating Temperature

(See Temperature Derating Table)

Commercial:        0 to 50°C
Wide:                -40 to 60°C  (-20°C AC cold start)
Extended:         -40 to 75°C   - not available for models with 

                                                 AC/DC Adapters 
Storage:          

  

-40 to 80°C

Humidity 

5 to 95% (non-condensing)

Altitude 

-100m to 4,000m (operational)

MTBF (hours)

Module Only:       

  

277,000 

AC/DC Adapter:    100,000

Warranty

5 year product warranty with 24/7/365 free Technical Support

2 year AC power adapter warranty

Page 18

AC/DC Adapter Temperature Derating

Total Available Wattage to RJ-45 Ports

Model

Watts Required

40

°C

50

°C

60

°C

GHPoE/Sx and GHPoEBT/Sx 60W

240 watts

Full Power

175 watts

115 watts

GHPoEBT/Sx 100W

400 watts

240 watts

175 watts

115 watts

The AC/DC Adapter Temperature derating table is not applicable to models with DC Terminal 

(see Ordering table for Direct DC -9 option).  The DC Terminal models will provide full PoE 

power over the operating temperature range of the module as long as the DC input power 

meets the requirements stated in the specification table.

Regulatory Compliances

Safety: 

UL 60950-1,  

UL-62368-1,  

IEC 62368:2014 /A11:2017,  

IEC 60950-1:2005+A1:2009,  

EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013,  

CAN/CSA C22.2 No. 60950-1,  

CAN/CSA C22.2 No. 62368-1-14,  

CE Mark

EMC: 

EN 55032/EN 55024 CE Emissions/Immunity,

EMI: 

CISPR 32,  

FCC 47 Part 15 Subpart B Class A

EMS: 

IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV,  

IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m,  

IEC 61000-4-4 EFT: Power: 1 kV; Signal:0.5 kV,  

IEC 61000-4-5 Surge: Power: 1 kV; Signal: 1 kV,  

IEC 61000-4-6 CS: Signal: 3 V,  

IEC 61000-4-8 (Magnetic Field),  

IEC 61000-4-11 

IP Rating:  IP20 Protection

Содержание OmniConverter GHPoE/Sx

Страница 1: ...heAC DC power adapter can be extended to five 5 years by registering the product at www omnitron systems com support within ninety 90 days from the date of shipment During the warranty period Omnitron...

Страница 2: ...per or fiber uplink ports and four 10 100 1000 RJ 45 copper Power Sourcing Power over Ethernet user ports The GHPoE Sx is a pre IEEE 802 3bt switch featuring up to 60W per user port models The GHPoEBT...

Страница 3: ...orced Disabled factory default UP PoE Forced Enabled SW7 DOWN L2CP Tunnel factory default UP L2CP Tunnel Discard SW8 DOWN OFF PoE Reset UP PoE Reset DIP switch Definitions SW1 and SW2 Mode of Operatio...

Страница 4: ...ice Mode Configured for Dual Device Mode and Directed Switch Mode the traffic from ports P1 and P2 is only forwarded to uplink port F1 and ports P3 and P4 are only forwarded to uplink port F2 This pre...

Страница 5: ...a loss of receive link on any uplink port When this DIP switch is in the UP PoE Reset position the module will disable PoE output power for 5 seconds following a loss of receive link on any uplink po...

Страница 6: ...equipment shall be located in the same immediate area such as adjacent cabinets as any other equipment that has a connection between the earthed conductor of the same DC supply circuit and the earthi...

Страница 7: ...0 VDC 52 0 to 56 0 VDC Maximum Power from PoE PSE port 15 4 watts 30 watts 60 watts 100 watts Minimum Voltage at PoE PD port input 37 0 VDC 42 5 VDC 42 5 VDC 41 1 VDC Minimum Power at PoE PD port 12...

Страница 8: ...with Gigabit Fiber or Copper Uplinks Unmanaged 6 Port High Power PoE Ethernet Switch Standard Compliances IEEE 802 3 IEEE 802 3af 15 40 watts max IEEE 802 3at 30 watts max High Power 60W PoE Environme...

Страница 9: ...t Extended 40 to 75 C not available for models with AC DC Adapters Storage 40 to 80 C Humidity 5 to 95 non condensing Altitude 100m to 4 000m operational MTBF hours Module Only 277 000 AC DC Adapter 1...

Страница 10: ...s product contact Omnitron Technical Support Phone 949 250 6510 Fax 949 250 6514 Address Omnitron Systems Technology Inc 38 Tesla Irvine CA 92618 USA Email support omnitron systems com URL www omnitro...

Отзывы: