NEVER ATTEMPT TO OPEN THE CHASSIS OR

SERVICE THE POWER SUPPLY. OPENING THE

CHASSIS MAY CAUSE SERIOUS INJURY OR DEATH.

THERE ARE NO USER REPLACEABLE OR

SERVICEABLE PARTS IN THIS UNIT.

WARNING!!!

DC Power

This module is intended for installation in restricted access areas. (“Les matériels 

sont destinés à être installés dans des EMPLACEMENTS À ACCÈS RESTREINT”). 

A restricted access area can be accessed only through the use of a special key, or 

other means of security.
The over current protection for connection with centralized DC shall be provided in 

the building installation, and shall be a UL listed circuit breaker rated 20 Amps, and 

installed per the National Electrical Code, ANSI/NFPA-70.
The GHPoE/Sx and GHPoEBT/Sx (60W models) re50 to +57VDC inclusive 

of tolerances (4.46A @ 56VDC max rated power) and the GHPoEBT/Sx (100W 

models) re52 to +57VDC inclusive of tolerances (7.31A @ 56VDC max 

rated power). See specification table for specific model requirements. 

Appropriate overloading protection should be provided on the DC power source 

outlets utilized.

DC Models Rear View: 2-Pin Terminal for DC Power

WARNING:

Only a DC power source that complies with

safety extra low voltage (SELV) requirements can be
connected to the DC-input power supply.

WARNING REGARDING EARTHING GROUND:

o

o

o

o

This equipment shall be connected to the DC supply

system earthing electrode conductor or to a bonding
jumper from an earthing terminal bar or bus to which the
DC supply system earthing electrode is connected.

This equipment shall be located in the same immediate

area (such as adjacent cabinets) as any other equipment
that has a connection between the earthed conductor of
the same DC supply circuit and the earthing conductor,
and also the point of earthing of the DC system. The DC
system shall not be earthed elsewhere.

The DC supply source is to be located within the same

premises as this equipment.

There shall be no switching or disconnecting devices in

the earthed circuit conductor between the DC source and
the earthing electrode conductor.

Locate the DC circuit breaker of the external power source, and switch the circuit 

breaker to the OFF position.
Prepare a power cable using a three conductor insulated wire (not supplied) with 

12AWG to 14AWG thickness.  Cut the power cable to the length required.
Strip approximately 3/8 of an inch of insulation from the power cable wires.
Connect the ground wire to the grounding screws on the back of the module.
Connect the power cables to the module by fastening the stripped ends to the DC 

power connector.

DC Models Rear View: Power Connections

WARNING:  The positive lead of the power source must be connected to the 

“+” terminal on the module and the negative lead of the power source to the 

“-“ terminal on the module as shown above. 

The power connections on the module are isolated.  This provides support of positive 

or negative power connections. 

Power Options

WARNING: Note the wire colors used in making the positive, negative and 

ground connections. Use the same color assignment for the connection at 

the circuit breaker.

Connect the power wires to the circuit breaker and switch the circuit breaker ON. 

If any module are installed, the Power LED will indicate the presence of power.

Содержание OmniConverter GHPoE/Sx

Страница 1: ...heAC DC power adapter can be extended to five 5 years by registering the product at www omnitron systems com support within ninety 90 days from the date of shipment During the warranty period Omnitron...

Страница 2: ...per or fiber uplink ports and four 10 100 1000 RJ 45 copper Power Sourcing Power over Ethernet user ports The GHPoE Sx is a pre IEEE 802 3bt switch featuring up to 60W per user port models The GHPoEBT...

Страница 3: ...orced Disabled factory default UP PoE Forced Enabled SW7 DOWN L2CP Tunnel factory default UP L2CP Tunnel Discard SW8 DOWN OFF PoE Reset UP PoE Reset DIP switch Definitions SW1 and SW2 Mode of Operatio...

Страница 4: ...ice Mode Configured for Dual Device Mode and Directed Switch Mode the traffic from ports P1 and P2 is only forwarded to uplink port F1 and ports P3 and P4 are only forwarded to uplink port F2 This pre...

Страница 5: ...a loss of receive link on any uplink port When this DIP switch is in the UP PoE Reset position the module will disable PoE output power for 5 seconds following a loss of receive link on any uplink po...

Страница 6: ...equipment shall be located in the same immediate area such as adjacent cabinets as any other equipment that has a connection between the earthed conductor of the same DC supply circuit and the earthi...

Страница 7: ...0 VDC 52 0 to 56 0 VDC Maximum Power from PoE PSE port 15 4 watts 30 watts 60 watts 100 watts Minimum Voltage at PoE PD port input 37 0 VDC 42 5 VDC 42 5 VDC 41 1 VDC Minimum Power at PoE PD port 12...

Страница 8: ...with Gigabit Fiber or Copper Uplinks Unmanaged 6 Port High Power PoE Ethernet Switch Standard Compliances IEEE 802 3 IEEE 802 3af 15 40 watts max IEEE 802 3at 30 watts max High Power 60W PoE Environme...

Страница 9: ...t Extended 40 to 75 C not available for models with AC DC Adapters Storage 40 to 80 C Humidity 5 to 95 non condensing Altitude 100m to 4 000m operational MTBF hours Module Only 277 000 AC DC Adapter 1...

Страница 10: ...s product contact Omnitron Technical Support Phone 949 250 6510 Fax 949 250 6514 Address Omnitron Systems Technology Inc 38 Tesla Irvine CA 92618 USA Email support omnitron systems com URL www omnitro...

Отзывы: