16.
Initial Setup
26
www.sinetech.co.za
SECTION A:
Standard: It will list local grid standard. A factory password is required to make any
changes. Contact local dealer only when a change to the standard is required.
CAUTION:
Incorrect settings can cause damage to the unit or render it
inoperable.
Nominal Output Voltage: 230V.
Nominal Output Frequency: 50HZ.
SECTION B:
This section’s contents may be different based on operation selected.
Allow AC charging duration: A time period allowing AC (grid) to charge battery.
With the set up 00:00-00:00, no time limitation for AC to charging applies.
AC output ON/Off Timer: Enables on/off timer for AC output. If set to 00:00/00:00,
this function is disabled.
Allow to charge battery: This option is automatically determined by setting in
“Charging source”. It cannot be modified here. When “NONE” is selected in
charging source section, this option becomes unchecked as grey text.
Allow AC to charge battery: This option is automatically determined by setting
in ”Charging source”. It cannot be modified here. When “Grid and PV” or “Grid or
PV” is selected in charging source section, this option is default selected. Under
Grid-tie mode, this option is invalid.