Assembly control
(ill.13) Insert the test pin with the
corresponding side into the socket or plug
to the end position. If the contact is
correctly assembled, the white marking
on the test pin must be still visible.
(ill.14) Screw on the cable gland, hand-
tight, with the tools PV-MS. Or
Screw on the cable gland, with the tools
PV-WZ-AD/GWD and PV-SSE-AD4
In any case:
The tightening torque must be adapted to
the solar cables used in each specific
case. Typical values lie in a range
between 2,5 Nm to 3 Nm.
Plugging and unplugging the cable
coupler without safety lock clip PV-SSH4
Plugging
(ill.15)Plug the coupling together until
they engage. Check correct engagement
by pulling on the coupling.
Unplugging
(ill.16)Compress the two snap-in springs
(X) by hand or with the PV-MS tool and
separate the coupling.
Plugging and unplugging the cable
coupler without safety lock clip PV-SSH4
Refer to cable manufactures specification for minimum bending radius.