Страница 1: ...User Manual V4 2 User Manual Installation Operation Omniksol 1k TL Omniksol 1 5k TL Omniksol 2k TL Omnik New Energy Co ltd...
Страница 2: ......
Страница 3: ...ation 16 5 1 Safety 16 5 2 Mounting Instructions 16 5 3 Safety Clearance 17 5 4 Mounting Procedure 18 5 4 1 Mounting with bracket 18 5 4 2 Mounting without bracket 20 5 5 Safety lock 22 5 5 1 Safety l...
Страница 4: ...User Manual V4 2 2 8 Recycling and Disposal 40 9 Troubleshooting 41 10 Abbreviation 42 11 Contact 43...
Страница 5: ...se keep this user manual all time available in case of emergency 1 2 Symbols Used DANGER DANGER indicates a hazardous situation which if not avoided will result in death or serious injury WARNING WARN...
Страница 6: ...pter 6 are only for qualified personnel who are intended to install or uninstall the Omnik Grid Tie Solar Inverter WARNING Do not use this product unless it has been successfully installed by qualifie...
Страница 7: ...tallation service recycling and disposal of the inverters must be performed by qualified personnel only in compliance with national and local standards and regulations Please contact your dealer to ge...
Страница 8: ...ctricity generators and public grid Danger of hot surface The components inside the inverter will release a log of heat during operation DO NOT touch aluminum housing during operating An error has occ...
Страница 9: ...nt and Product Safety Act in Europe Standards Association of Australian The inverter complies with the requirement of the AS4777 CE Mark Equipment with the CE mark fulfils the basic requirements of th...
Страница 10: ...User Manual V4 2 8 3 Product Information 3 1 Overview Industrial Layout Excellent Heat Elimination...
Страница 11: ...ranges enables more PV panels connected Wide MPP voltage range ensure high yield under various weather conditions High MPP tracking accuracy ensure the minimum power loses during converting Complete s...
Страница 12: ...Full Load Harmonic distortion THD at nominal output 2 AC Connector Plug in connector Power consumption Own consumption in operation Pown AC W 30 Power consumption at night Pnig AC W 0 Power consumpti...
Страница 13: ...Omniksol 1 5k 2k TL Type Omniksol 1 5k TL Omniksol 2k TL Input DC Max PV generator power Ppv W 1750 2300 Max DC voltage Vmax DC V 500 MPPT DC voltage range Vmppt V 120 450 Turn off DC Voltage Vmin DC...
Страница 14: ...AS4777 Normative reference CE compliant according to EN 62109 EN 61000 6 1 EN 61000 6 3 EN 61000 6 2 EN 61000 6 4 EN61000 3 2 EN61000 3 3 EN61000 3 12 EN61000 3 11 Dimensions and weight Dimensions WxH...
Страница 15: ...nside completeness for any visible external damage on the inverter or any accessories Contact your dealer if anything is damaged or missing A B C D E F G H Object Quantity Description A 1 Omnik invert...
Страница 16: ...e Front Bottom Object Description A Removable front shield B LED light Green RUN C LED light Red FAULT D LED light Yellow COM E Function key for displays and choice of language F Monitoring LCD with b...
Страница 17: ...mber SN type of the inverter as well as inverter specifications are specified on the side name plate The name plate is on the middle part of the right side of the inverter housing And the following fi...
Страница 18: ...with HIGH VOLTAGE power generation device the installation must be performed by qualified personnel only in compliance with national and local standards and regulations NOTICE NOTICE due to the inapp...
Страница 19: ...device is properly fixed to the wall It is not recommended that the inverter is exposed to the strong sunshine because the excess heating might lead to power reduction The ambient temperature of inst...
Страница 20: ...s on the wall according to the wall mounting bracket in the carton box Depth 50mm 250 213 First according to the marks drill 4 holes in the wall Then place four expansion tubes in the holes using a ru...
Страница 21: ...2 19 2 First check the 4 holes in the backside of the inverter Then lift the inverter carefully align the 4 holes in the inverter and the 4 hooks on the bracket and finally attach the inverter to the...
Страница 22: ...he wall according to the paper installation position scale packed in the carton box 2 First according to the marks drill 4 holes in the wall Then place four expansion tubes in the holes using a rubber...
Страница 23: ...the inverter carefully align the 4 holes in the inverter and the 4 screws in the wall and finally attach the inverter to the screws slightly 4 Please carefully check the accessories and original cart...
Страница 24: ...erter as the picture showed below Recommended padlock dimension 5 5 2 Safety lock without the wall mounting bracket After the inverter is hang up on the wall install the lock bracket on the aluminium...
Страница 25: ...epair please keep the key of the padlock in a safe place DANGER DANGER to life due to potential fire or electricity shock With the inverter powered comply with all prevailing national regulations on a...
Страница 26: ...Description A Plug connectors for DC input B RS232 RS485 interface C Terminal for grid connection AC output NOTICE Electrical connections shall be carried out in accordance with the applicable regula...
Страница 27: ...value if the leakage current exceeds the permitted range the RCD will disconnect the inverter from the AC load 2 Assembly Instructions a Strip the cable with the length 0 276 inches 9 32 7mm and pleas...
Страница 28: ...L and PE cable accordingly to the corresponding position and fully tighten the screws e Aim the terminals on the straight plug to the holes of the grommet and then compress them together f Finally co...
Страница 29: ...the preparation and assembly instructions described here are disregarded then neither safety nor compliance with the technical data can be guaranteed For protection against electric shock PV connector...
Страница 30: ...and water with sealing caps Plugged parts are watertight IP67 They can not be used permanently under water Do not lay the MC PV connectors on the roof surface See the MC catalogue 2 Solar line for te...
Страница 31: ...ZM 19100 ill 3 Open end spanner PV MS 1 set 2 pieces Order No 32 6024 ill 4 PV WZ AD GWD socket wrench insert to tighten Order No 32 6006 ill 5 PV SSE AD4 socket wrench insert to secure PV SSE AD4 Ord...
Страница 32: ...p connection may exceed the permitted limits Check dimension b according to the following table ill 10 Strip cable insulation L 6 7 5 mm Take care not to cut individual strands Recommended tool Stripp...
Страница 33: ...he tightening torque must be adapted to the solar cables used in each specific case Typical values lie in a range between 2 5 Nm to 3 Nm Plugging and unplugging the cable coupler without safety lock c...
Страница 34: ...ultipoint communications that is up to 50 Omnik inverters can be connected one by one through these 2 plugs and the cables the upper computer can communicate with these inverters via a single signal c...
Страница 35: ...er so it is easy for user to check and set the data In addition the user can press the function key to illuminate the LCD screen NOTICE Omnik inverter is not an aligned measuring instrument for curren...
Страница 36: ...put power Pac xxxx W The top line Line 1 shows current state information by default and by pressing function key it will display different operating information as the following flow chart and table N...
Страница 37: ...tion Pac xxxx W Iac Pac xxxx W E total Pac xxxx W Vpv Pac xxxx W Ipv Pac xxxx W E today Pac xxxx W Vac Pac xxxx W Model Pac xxxx W Ver Pac xxxx W Set language Pac xxxx W Frequency Pac xxxx W S N WiFi...
Страница 38: ...er The Firmware version Set Language Several languages are provided for users reference to 7 3 for further information Vac The grid voltage S N WiFi Displays the serial number of the WiFi card such as...
Страница 39: ...5kW 2 0kW inverters Only perform this operation when the accumulative generated electricity is less than 1KWh 2 Operation steps are as following a Power on the inverter with only DC side connected whi...
Страница 40: ...User Manual V4 2 38 c When the LCD displays your desired Safety Standard hold the Function button for 5 seconds or more until it shows Safety Standard OK d The Safety Standard setup is now completed...
Страница 41: ...e Utility Loss No Utility Island PV Over Voltage Input voltage too high Over Temperature Temperature abnormal Isolation Fault Isolation failure Relay Check Fail Output relay failure DC INJ High Output...
Страница 42: ...reached the end of its life must be collected separately and returned to an approved recycling facility Any device that you no longer required must be returned to your dealer or you must find an appr...
Страница 43: ...ility Loss 1 Grid is not connected 2 Check grid connection cables 3 Check grid usability 4 If grid is ok and the problem persists maybe the fuse in the inverter is open please call service Over Temper...
Страница 44: ...at the Maximum Power Point Impp Amperage at Maximum Power Point AC Alternating Current Form of electricity supplied by Utility Company DC Direct Current Form of electricity generated by PV modules VDE...
Страница 45: ...4 215123 Suzhou China Tel 86 512 6295 6676 Fax 86 512 6295 6682 Email info omnik solar com www omnik solar com Omnik German Service Center Omnik GmbH Forsthausstr 8A 65479 Raunheim Tel 49 179 9762 654...