background image

INSTALLATION

NOTICE:

Install this RO system on the cold water line only.

Completely read these instructions before starting installation.

Carefully read and follow all safety instructions in this manual
or on system.

This is the safety alert symbol. When you see this symbol on
your RO system or in this manual, look for one of the follow-

ing signal words and be alert to the potential for personal injury!

DANGER

warns about hazards that 

will

cause seri-

ous personal injury, death or major property damage if ignored.

WARNING

warns about hazards that 

can

cause seri-

ous personal injury, death or major property damage if ignored.

CAUTION

warns about hazards that 

will

or 

can

cause minor personal injury or property damage if ignored.
The word 

NOTICE

indicates special instructions which are important

but not related to hazards.

The preservatives on the RO membrane can cause

severe digestive disturbance and diarrhea if ingested into the human
body. Flush the membrane housing twice and flush the membrane
itself twice before first using the RO water. See “Flushing the
System”, Page 4.

Tools Needed:

Drill
3/8” bit
1-1/8” bit (optional for hole for faucet)
Wrench
Phillips screwdriver 
Pliers
Shallow pan
Bucket (for sanitizing the membrane housing)
9-Volt battery (not included). Purchase separately for 
Model RO2000-TDS

Faucet Installation. See Figure 1.

1. Turn off the cold water supply valve.
2. If necessary, drill (or punch) a 1-1/8” hole in the sink top. 
3. Remove the nut and spacer from the RO faucet and feed the two

lengths of black tubing (attached to the faucet stem) down
through the hole in the sink top until the faucet is seated on the
sink top. The vertical ridge on the faucet handle should be facing
toward the user.

4. Reach below the sink top and slide the channel washer up the

faucet stem. Install the spacer tube (if needed) and tighten the
stem nut (cone shaped side up) on the channel washer. Tighten
the stem nut just enough to keep the faucet securely in place; do
not overtighten.

NOTICE: 

Be sure that the channel in the channel washer faces up

and that it completely bridges the hole in the sink top (that is, it
should be tightening against both sides of the hole).

NOTICE:

For Model RO2000-TDS, make sure that the grey cable

coming from the faucet base is lying inside the channel washer,
and that the edges of the channel washer don’t pinch the cable.

Waste Drain Saddle Installation

1. Install the Waste Drain Saddle on the sink drain, above the trap

and below the bottom of the RO faucet.

®

2500 165th Street • Hammond, Indiana 46320
1-800-937-6664  •  www.omnifilter.com

Reverse Osmosis System

INSTALLATION INSTRUCTIONS

Models RO2000 and RO2000-TDS

IN

OUT

IN

IN

OUT

OUT

IN

IN

OUT

OUT

3639 0100 ASB

©2001, Omnifilter  

Printed in U.S.A.  

OM539 (Rev. 7/20/01)

Channel Washer

Stem Nut

Cold Water Shut-off Valve

Cold Water Line

Threaded Stem
of Faucet

Existing Sink
Faucet Sprayer Hole

Vertical ridge of
faucet handle.

Figure 1

Waste
Saddle

1" Minimum

Figure 2:Waste Drain Saddle Installation

Содержание RO2000 Series

Страница 1: ...ssary drill or punch a 1 1 8 hole in the sink top 3 Remove the nut and spacer from the RO faucet and feed the two lengths of black tubing attached to the faucet stem down through the hole in the sink top until the faucet is seated on the sink top The vertical ridge on the faucet handle should be facing toward the user 4 Reach below the sink top and slide the channel washer up the faucet stem Insta...

Страница 2: ...ough the wall of the supply line Do not force it and do not overtighten REVERSE OSMOSIS RO UNIT ASSEMBLY AND INSTALLATION 1 Place the storage tank in a convenient location under the sink Make sure that the tank valve is OPEN See Figure 4 2 Place the RO unit in a shallow pan on the floor in front of the sink 3 Connect the free end of the 1 4 black tube out of the faucet to the compression fitting c...

Страница 3: ...itor Be sure that the connection ports on the electronics enclosure face down 2 Run the grey telephone style cable with the yellow plug from the RO faucet to the right hand yellow port on the TDS Monitor 3 Run the grey telephone style cable from the white flow switch to the left hand port on the TDS Monitor 4 Remove the lid from the monitor and install a 9 volt battery pur chase separately Use a p...

Страница 4: ...any tubing 5 Using the plastic tank wrench supplied remove Pre Filter Tanks TO1 and CB1 Be careful the tanks will be full of water 6 Remove the used cartridges and dispose of them 7 Check the tank O Rings to be sure that they are seated properly Apply vegetable oil to the O Rings 8 Rinse the tanks with clear water no soap and wipe them out with a clean rag or paper towel 9 Put the replacement filt...

Страница 5: ...e the O Ring with vegetable oil 2 Unscrew the compression nut holding the black tube onto the membrane housing 3 Gently remove the tube from the membrane housing port keep the nut on the tube 4 Remove and discard the flow restrictor from the end of the black tube see Figure 10 5 Install the new flow restrictor in the end of the tubing as shown in Figure 10 Make sure that the collar on the flow res...

Страница 6: ...I NSF Standard 58 for the reduction of Fluoride Cysts Lead TDS Nitrate and Nitrite For further operating installation or maintenance assistance Call Omnifilter Customer Service at 800 937 6664 The Chlorine claim was tested off of the R200 post filter NOTICES Daily production rate is 13 gpd The reverse osmosis system contains a replaceable treatment component critical for the effective reduction of...

Страница 7: ...orter à la Figure 1 1 Fermer le robinet d arrivée d eau froide 2 Au besoin percer ou perforer un trou de 1 1 8 pouce dans le dessus de l évier 3 Déposer l écrou et l entretoise du robinet d eau traitée de l évier et faire passer les deux tubes noirs branchés sur la tige du robinet dans le trou de l évier jusqu à ce que le robinet repose sur l évier La saillie verticale de la poignée du robinet doi...

Страница 8: ...asser à l opération 5 Dans le cas du modèle RO2000 TDS passer à l opération 4 qui suit 4 Visser le contacteur débitmétrique blanc sur l extrémité du robinet se reporter à la Figure 6 A Piercing Needle Cold Water Pipe B C 3631 0100 Secure the Saddle Valve by tightening the nuts and bolts Turn handle clockwise to pierce the supply line with the piercing needle Figure 3 Installation du robinet à étri...

Страница 9: ...dans un endroit pratique sur le mur à l aide des attaches autoadhésives du module de contrôle S assurer que les orifices de branchement du boîtier électron ique sont orientés vers le bas 2 Amener le câble gris de type téléphone muni d une prise jaune branché sur le robinet d eau traitée de l évier jusqu à l orifice jaune qui se trouve à droite du module de contrôle des matières totales dissoutes 3...

Страница 10: ... d eau traitée et les mettre dans un bac creux sur le plancher à l avant de l évier NOTA Ne débrancher aucun tube 5 À l aide de la clé en plastique fournie déposer les cuves des cartouches préfiltrantes TO1 et CB1 Prudence les cuves sont pleines d eau 6 Sortir les cartouches filtrantes puis les jeter 7 Vérifier les joints toriques des cuves et s assurer qu ils reposent adéquate ment Appliquer de l...

Страница 11: ...ice de la cuve de la membrane laisser l écrou sur le tube 4 Déposer et jeter le limiteur de débit de l extrémité du tube noir se reporter à la Figure 10 5 Poser le limiteur de débit neuf dans l extrémité du tube comme il est illustré à la Figure 10 S assurer que le rebord du limiteur de débit repose contre l extrémité du tube NOTA Ne pas couper le limiteur de débit 6 Introduire le tube noir d envi...

Страница 12: ...SF en ce qui concerne la réduction de fluore de kystes de plomb de matières totales dissoutes de nitrate et de nitrite Pour tout autre renseignement concernant le fonctionnement l installation ou l entretien Appeler le service à la clientèle Omnifilter en composant le 800 937 6664 La réduction de chlore a été testée avec une cartouche postfiltrante R200 NOTA La production journalière d eau traitée...

Страница 13: ...del fregadero 3 Saque la tuerca y el espaciador del grifo de OI y haga pasar dos largos del tubo negro conectado al vástago del grifo hacia abajo por el orificio en la parte superior del fregadero hasta que el grifo quede asentado sobre la parte superior del fregadero La protuberancia vertical del mango del grifo debe quedar mirando hacia el usuario 4 Debajo de la parte superior del fregadero haga...

Страница 14: ...lo RO2000 vaya al paso 5 Para el Modelo RO2000 TDS vaya al paso 4 a continuación 4 Enrosque el conmutador de flujo blanco al extremo del grifo ver Figura 6 14 A Piercing Needle Cold Water Pipe B C 3631 0100 Secure the Saddle Valve by tightening the nuts and bolts Turn handle clockwise to pierce the supply line with the piercing needle Figura 3 Instalación de la Llave de Silla para Agua Fría Shut O...

Страница 15: ... monitor Asegúrese de que las aberturas de conexión en el recinto electrónico estén mirando hacia abajo 2 Haga correr el cable gris tipo telefónico con el enchufe amarillo desde el grifo de OI a la abertura derecha amarilla en el Monitor TDS 3 Haga correr el cable gris tipo telefónico desde el conmutador blanco de flujo a la abertura izquierda en el Monitor TDS 4 Saque la tapa del monitor e instal...

Страница 16: ...uercas para tanques de plástico suministrada saque los Tanques de Prefiltración TO1 y CB1 Tenga cuidado ya que los tan ques estarán llenos de agua 6 Saque los cartuchos usados y deséchelos 7 Inspeccione los aros tóricos del tanque para asegurarse de que estén debidamente acomodados Aplique aceite vegetal en los aros tóricos 8 Enjuague los tanques con agua limpia sin jabón y séquelos con un paño li...

Страница 17: ...embrana 3 Delicadamente retire el tubo de la abertura de la envoltura de la membrana manteniendo la tuerca en el tubo 4 Saque y deseche el restrictor de flujo del extremo del tubo negro ver Figura 10 5 Instale el nuevo restrictor de flujo en el extremo de la tubería según se ilustra en la Figura 9 Asegúrese de que el collarín en el restrictor de flujo quede acomodado contra el extremo del tubo AVI...

Страница 18: ...uro esporas plomo TDS Nitrato y Nitrito Para mayor asistencia sobre el funcionamiento instalación o mantenimiento Llame al departamento de servicio al cliente de Omnifilter al 800 937 6664 La reivindicación sobre el cloro no fue incluida en la prueba del postfiltro R200 AVISOS La tasa de producción diaria es de 13 gpd El sistema de osmosis inversa contiene un componente de tratamien to reemplazabl...

Страница 19: ...19 ...

Страница 20: ...20 ...

Отзывы: