![Omnicomm LLS 5 Скачать руководство пользователя страница 5](http://html2.mh-extra.com/html/omnicomm/lls-5/lls-5_user-manual_4035521005.webp)
Atmospheric pressure, kPa
From 84 to 107
Maximum relative humidity at 25 °С
(without moisture condensation), %
100
Ingress protection rating
IP69k
Operating mode
Continuous
Internal filter size
From 0 to 30
Measurement time period, s
1
Overall dimensions, mm
87.3 x 83.5 x (21 + length of the measuring probe)
Weight, kg
Not more than 2
Average service life, years
8
Digital reading range corresponding to
the maximum value of the measured
level
1…4095
Digital reading range corresponding to
the minimum value of the measured
level
0…1023
Temperature measuring range, °C
From -40 to +80
Absolute temperature measurement
error throughout the whole range of
working temperature, °C
± 5
Parameters
Value
5
Technical Specifications