background image

© 2011 Omnicell, Inc.

Fingerprint Scanner & Card Reader Guide/

67-2100 Rev A

Installing a Fingerprint Scanner on an AWS

3-5

Install the Fingerprint Scanner

5. Plug the scanner into the USB port on the bottom of the keyboard tray.

Figure 3-7.

Connect the USB cable to the extender 

6. Reconnect the any cables that have been disconnected during the install of the fingerprint 

scanner.

7. Set the keyboard in place.

8. Secure the keyboard with the screws previously removed.

9. Power on the unit and test the fingerprint scanner to ensure that it is working.

Содержание G4

Страница 1: ...FingerprintScanner Card Reader Guide 67 2100 Rev A Install and Service for G4 Systems...

Страница 2: ...Charleston Road Mountain View CA 94043 650 251 6100 www omnicell com Omnicell and the Omnicell design mark OmniBuyer OmniCenter OmniRx OmniSupplier SafetyMed SafetyPak SafetyStock and Sure Med are reg...

Страница 3: ...nner on a 1 2 and 3 Cell 1 1 Install the Fingerprint Scanner 1 1 Installing a Fingerprint Scanner on an OmniRx 2 1 Remove the Omni Rx Keyboard 2 1 Install the Fingerprint Scanner 2 3 Installing a Fing...

Страница 4: ...d 3 cell cabinet is located on the card reader bracket and should always be installed with the card reader bracket as a single piece Install the Fingerprint Scanner 1 Perform a graceful shutdown of th...

Страница 5: ...ader Guide 67 2100 Rev A 2011 Omnicell Inc 4 Use the 2378 cam lock key to unlock the E Box Figure 1 2 Unlock the eBox 5 Slide the console out until it locks into place 6 Place the scanner and card rea...

Страница 6: ...er Guide 67 2100 Rev A Installing a Fingerprint Scanner on a 1 2 and 3 Cell 1 3 Install the Fingerprint Scanner 7 Secure the fingerprint scanner bracket with the four screws provided Figure 1 4 Secure...

Страница 7: ...mbo route the two USB cables through the plastic cable clip provided on the side of the console If only a scanner or card reader is being installed route the single USB cable through the plastic clip...

Страница 8: ...the two clips near the USB ports Figure 1 7 Route the cable s tough the two clips near the USB ports 11 Plug the USB cable s into the USB ports on the side of the eBox The fingerprint scanner USB ca...

Страница 9: ...2011 Omnicell Inc 13 LAdd the M4x14 security screw to the top of the printer enclosure securing it to the console cover Figure 1 9 Add the M4x14 security screw 14 Lock the CT PC console into place us...

Страница 10: ...Guide 67 2100 Rev A Installing a Fingerprint Scanner on a 1 2 and 3 Cell 1 7 Install the Fingerprint Scanner 16 Power on the cabinet 17 Close the keyboard door 18 Power up the G4 console 19 Test the f...

Страница 11: ...rprint Scanner on an OmniRx Remove the Omni Rx Keyboard 1 Perform a graceful shutdown of the OmniRx and unplug the power cord from the rear of the unit 2 Remove the two screws on the under side of the...

Страница 12: ...eader Guide 67 2100 Rev A 2011 Omnicell Inc 3 Remove the four screws on the keyboard tray that secure the keyboard to the console Figure 2 2 Remove the top four screws that secure the keyboard 4 Lift...

Страница 13: ...Scanner on an OmniRx 2 3 Install the Fingerprint Scanner 5 Remove the nut that secures the keyboard ground cable Figure 2 4 Remove the keyboard ground cable nut 6 Remove the ground cable Install the F...

Страница 14: ...rprint Scanner Card Reader Guide 67 2100 Rev A 2011 Omnicell Inc 2 Ensure that the gasket around the fingerprint scanner is secure Figure 2 5 Ensure the gasket is secure 3 Ensure the gasket around the...

Страница 15: ...to place and secure it with the five screws provided Ensure the cable is facing toward the data cable Figure 2 7 Secure the fingerprint scanner to the keyboard tray 5 Plug the scanner into the USB por...

Страница 16: ...he Fingerprint Scanner Fingerprint Scanner Card Reader Guide 67 2100 Rev A 2011 Omnicell Inc 7 Set the keyboard in place 8 Secure the keyboard with the screws previously removed 9 Power on the unit an...

Страница 17: ...Reader Guide 67 2100 Rev A 3 1 Installing a Fingerprint Scanner on an AWS Remove the AWS Keyboard 1 Remove the eight screws thatsecure the keyboard casing on the AWS or AWS G4 Figure 3 1 Remove the e...

Страница 18: ...ent remove the two innermost screws Figure 3 2 Remove the innermost screws on the card reader 3 Lift the keyboard from the keyboard holder Figure 3 3 Lift the keyboard from the keyboard enclosure Note...

Страница 19: ...on an AWS 3 3 Install the Fingerprint Scanner 4 Disconnect the keyboard and keypad cables Install the Fingerprint Scanner 1 If there is a blank plate in place of the scanner location remove the plate...

Страница 20: ...011 Omnicell Inc 3 Ensure the gasket around the keyboard is secure as well Figure 3 5 Ensure the gasket around the keyboard is secure 4 Place the fingerprint scanner into place and secure it with the...

Страница 21: ...into the USB port on the bottom of the keyboard tray Figure 3 7 Connect the USB cable to the extender 6 Reconnect the any cables that have been disconnected during the install of the fingerprint scann...

Страница 22: ...m Did this document meet your needs If so please let us know what we re doing right If not please provide specific feedback Email or fax your feedback as follows Email Documentation Requests email gro...

Страница 23: ......

Отзывы: