background image

 

 

 

 

 

 

14 

 

PRINT TROUBLESHOOTING 

 

Issue

 

Possible Cause

 

Solution

 

Labels won’t feed 

Sensor location 
Sensor setting 

Re-locate sensor 
Check gap sensing in menu 
Re-calibrate sensor if necessary. 

Barcode not straight 

Labels slipping 

Increase head pressure or change 
roller under head 

No print at all 

Ribbon in upside down 
Wrong ribbon 

Turn ribbon around 
Change ribbon to known good ribbon. 

Partial print on one side 

Head pressure 

Re-balance 

Print blurring 

Too much ink 

Reduce darkness 

Print too light 

Too little ink 

Increase darkness 
Slow print speed 
Increase head pressure both sides 

ENCODING TROUBLESHOOTING 

 

Issue

 

Possible Cause

 

Solution

 

Multi tag error 

Reading more than one tag 

Turn the read power down 

Tag not found 

Cannot read or write the ag 

Adjust the read  and/or write power 

Read only error 

Calibration is wrong 

Turn the write power up 

Encoding adjacent label 

The distance between 
labels is too small 

Adjust Tag offset 

Printer missing tag between 
each printed tag 

Gap Levels Incorrect 

Re calibrate Gap Levels 

Print without RFID encoding 

‘Write data to RFID tag’ 
deselected  

Select ‘write data to RFID tag’ in s/w 

WRITE TAG ERROR 
displayed on label and 

 RFID tag error code  

# 1018 displayed 

Encoding data type is set to 
ASCII string 

Select HEX encoded string in data type 
menu 

Содержание Sato CL4NX

Страница 1: ...PAG000726 02 072016 Omni ID Sato CL4NX Guide Omni ID office locations US UK China India Germany...

Страница 2: ...es for detailed instructions CONTENTS PRINTER SETUP 3 RIBBONS 5 PRINTER SETTINGS 6 OPTIMIZED ENCODING SETTINGS FOR OMNI ID LABELS 9 SOFTWARE SETUP 11 PRINT TROUBLESHOOTING 14 ENCODING TROUBLESHOOTING...

Страница 3: ...Load label spool and lock in place with the Guide Arm 2 Slide Guide 2 to the rightmost position and then move it back left to secure the label Note The Sato CL4NX has a sliding Gap and I Mark sensor a...

Страница 4: ...d the labels under the Print Head Head pressure dials are located on top of the print head these should be adjusted so that the print quality is consistent without applying excessive pressure 5 Final...

Страница 5: ...duct Type SATO Y70110200720 Full resin carbon ribbon Load the ribbon into the printer so that the matt surface is visible to the human eye from the front of the printer The matt surface is the printin...

Страница 6: ...6 PRINTER SETTINGS This section provides specific details and guidelines associated with encoding Omni ID labels 1 Setup RFID functionality of the printer using the main control panel...

Страница 7: ...he slowest print speed that is available should be used to print Compound labels This is typically 2 inches per second Advanced printer adjustments Pitch and offset should be set to 0mm Print Mode Pri...

Страница 8: ...s and we do recommend you do this to avoid any erroneous settings in the command reaching the printer Command settings are those created in the label design software and the default setting on the pri...

Страница 9: ...ror due to the size of the small IQ Label tags the sensor in the print head can sometimes detect the information from the tag behind so it is necessary to change the sensor pitch to read the right tag...

Страница 10: ...10 The table below provides the optimal settings for all variants of Omni ID IQ Label tags...

Страница 11: ...11 SOFTWARE SETUP Recommended software for Sato CL4NX is NiceLabel Pro Please Refer to NiceLabel Designer Pro user guide for detailed instructions link is on Page 2...

Страница 12: ...12...

Страница 13: ...13...

Страница 14: ...eed Increase head pressure both sides ENCODING TROUBLESHOOTING Issue Possible Cause Solution Multi tag error Reading more than one tag Turn the read power down Tag not found Cannot read or write the a...

Страница 15: ...ed in for successful encoding and printing If in any instance you unroll the labels i e to split a large roll into a smaller roll you must ensure to re roll them in the correct orientation The images...

Страница 16: ...16 IQ 100 in printer media facing out antenna facing up IQ 400 in printer media facing out antenna facing up...

Страница 17: ...cing compliance Example of GID 96bit scheme Header This is a static binary number which is converted into hexadecimal that identifies that the coding system being used is GID 96bit General Manager Num...

Отзывы: