9 omnicubed.com
2. Connect the tubing in a closed loop.
3. Pump the plunger until the red collar
remains hidden.
4. Begin timing: The red collar should not
appear for at least 10 minutes.
Pump Recharging
1. Plug the smart charger into a wall
outlet. Use only the included smart
charger.
2. Connect the smart charger to the
pump.
3. Observe the LED on the smart
charger. Red indicates charging; green
indicates fully charged. Recharging
requires up to 3 hours.
Vacuum Cup Testing
Follow these steps to determine if
maintenance or replacement parts are
needed.
1. Place a cover on the cup.
en