OMICRON Lab  

11 

Technical data 

 

 

 

Technical data 

5.1 

B-WIT 100 Wideband Injection Transformer 

Table 5-1 

Specifications 

Characteristic

 

 Rating

 

Usable frequency range 

1 Hz 

– 10 MHz 

Insertion loss

1

 

< 0.5 dB @ 10 kHz 

3 dB frequency range

2

 

7 Hz 

– 5 MHz (typ.) 

Pri-Sec Isolation voltage 

600 V CAT II 

Pri-Sec capacitance 

120 pF @ 1kHz (typ.) 

Max. volt-second 

3.5e-3 Vs (typ.) 

DC saturation current 

15 mA (typ.) 

Table 5-2 

Absolute maximum ratings (device will be destroyed) 

Characteristic 

 Rating 

Absolute max current 

1 A (fuse) 

Maximum AC voltage 

10 V

RMS

 

Table 5-3 

Environmental conditions 

Characteristic

 

 Rating

 

Operating temperature 

-

20 °C … +60 °C / -4 °F … +140 °F 

Relative humidity 

5 % … 80 % 

Maximum altitude 

2,000 m / 6,561 ft 

Table 5-4 

Mechanical data 

Characteristic 

 Rating 

Dimensions (with connectors) 

129 mm x 64 mm x 32.5 mm 
5.1 inch x 2.52 inch x 1.28 inch 

Weight 

0.25 kg / 0.6 lbs 

                                                      

1

 

S21 measurement with 50 Ω termination resistor. 

2

 S21 measurement with -10 dBm and 10 

Ω secondary resistance (0 dB is normalized to 10 Ω termination). 

Содержание B-WIT 100

Страница 1: ...nstrucciones de seguridad Ohutusjuhised Turvallisuusohjeet Consignes de s curit Sigurnosne upute Biztons gi utas t sok Istruzioni di sicurezza Saugos nurodymai Dro bas instrukcijas Veiligheidsinstruct...

Страница 2: ...recognition and or storage in electronic data processing systems requires the explicit consent of OMICRON electronics Reprinting wholly or in part is not permitted The product information specificati...

Страница 3: ...kovatelja 19 Biztons gi utas t sok rendeltet sszer haszn lat s kezel i szakk pes t si k vetelm nyek 19 Istruzioni di sicurezza utilizzo previsto e qualifiche degli operatori 20 Saugos nurodymai numaty...

Страница 4: ...tended for household use After use the test set cannot be disposed of as household waste For customers in EU countries incl European Economic Area OMICRON test sets are subject to the EU Waste Electri...

Страница 5: ...nto control loops in combination with a frequency response analyzer like Bode 100 B WIT 100 and B LFT 100 have been especially designed for the use in laboratory and manufacturing environments Safety...

Страница 6: ...e B WIT 100 or B LFT 100 shall only be carried out by authorized and qualified personnel Before starting to work clearly establish the responsibilities of all personnel involved Testing with the B WIT...

Страница 7: ...BNC to 4 mm banana adapter Figure 3 1 B WIT 100 connector description INPUT connector BNC plug to connect the B WIT 100 injection transformer to the signal source EARTH TERMINAL to connect device to...

Страница 8: ...er BNC to 4 mm banana adapter Figure 3 2 B LFT 100 connector description INPUT connector BNC plug to connect the B LFT 100 injection transformer to the signal source EARTH TERMINAL to connect device t...

Страница 9: ...injection resistor Ri is inserted to the loop as shown in the figure below The input of the injection transformer is connected to the output of the vector network analyzer The output of the injection...

Страница 10: ...els 30 VAC or 60 VDC CAUTION Minor or moderate injury in case of equipment failure Always connect the injection transformer s earth terminal to safety ground using a proper ground connection when volt...

Страница 11: ...2 Absolute maximum ratings device will be destroyed Characteristic Rating Absolute max current 1 A fuse Maximum AC voltage 10 VRMS Table 5 3 Environmental conditions Characteristic Rating Operating t...

Страница 12: ...5 2 Typical B WIT 100 low saturation4 power level 3 S21 measurement with 10 dBm and 10 secondary resistance 0 dB is normalized to 10 termination 4 Saturation defined as 20 dBc at the 10 injection res...

Страница 13: ...nt 0 8 mA typ Table 5 6 Absolute maximum ratings device will be destroyed Characteristic Rating Absolute max current 0 1 A fuse Maximum AC voltage 10 VRMS Table 5 7 Environmental conditions Characteri...

Страница 14: ...ge gain with 1 k secondary resistance and 0 dBm signal source level 7 Saturation defined as no visible distortions at 1 k injection resistor 50 signal source impedance 20 15 10 5 0 1E 2 1E 1 1E 0 1E 1...

Страница 15: ...com At our technical support hotline you can reach well educated technicians for all your questions Competent and free of charge Make use of our technical support hotlines Americas 1 713 830 4660 or 1...

Страница 16: ...B WIT 100 und B LFT 100 angegebenen maximalen Spannungen und Str me Obwohl die Einspeise bertrager B WIT 100 und B LFT 100 die Anforderungen der Schutzklasse II erf llen wird empfohlen den Erdungsansc...

Страница 17: ...nger Overskrid aldrig de maksimale v rdier der er angivet p frontpanelet eller i de tekniske specifikationer for sp nding og str m vedr rende B WIT 100 og B LFT 100 Selvom B WIT 100 og B LFT 100 er ap...

Страница 18: ...sutatakse ainult pinge ja voolutugevuse ohutusandureid Veenduge et need andurid oleks igesti maandatud koosk las andurite maaletootja te juhistega rge kunagi kasutage seadet k rgemal kui 2000 m Enne s...

Страница 19: ...ponske i strujne sonde Uvjerite se da su te sonde ispravno uzemljene u skladu sa smjernicama njihovih proizvo a a Nikada ne upravljajte ure ajem na visini iznad 2000 m Prije upravljanja ure ajima B WI...

Страница 20: ...ndiklius U tikrinkite kad ie bandikliai b t tinkamai eminti kaip nurodyta j gamintojo parengtose taisykl se Niekada nenaudokite renginio didesniame nei 2000 m auk tyje Prie naudodami B WIT 100 ir B LF...

Страница 21: ...gi s prawid owo uziemione zgodnie z wytycznymi ich producenta Nigdy nie u ywaj urz dzenia na wysoko ciach przekraczaj cych 2000 m Przed rozpocz ciem pracy z urz dzeniami B WIT 100 i B LFT 100 zawsze s...

Страница 22: ...to aby boli tieto sondy riadne uzemnen pod a pokynov v robcu Zariadenie nikdy nepou vajte vo v kach nad 2000 m Pred pou van m B WIT 100 a B LFT 100 sa v dy uistite e zariadenie ani jeho pr slu enstvo...

Страница 23: ...ligt i enlighet med tillverkarens anvisningar Anv nd aldrig enheten p h jder ver 2 000 m Innan du anv nder B WIT 100 och B LFT 100 ska du alltid se till att varken enheten eller dess tillbeh r r skada...

Страница 24: ...Version 1 4 info omicron lab com www omicron lab com OMICRON Lab 2018 Injection Transformer User Manual English All rights reserved ENU 1189 05 04...

Отзывы: