DEVICE SPECIFICATIONS 

Voltage: 

7-35 Volts D.C.

5-24 Volts A.C.

Current: 

80 mA max. 

Relay contacts: 

30 Volt, 2 Amp D.C. SPST. 

125 Volt, 1 Amp A.C. SPST. 

Frequency: 

2.4-2.48GHz 

Transmission Power: 

7 dBm 

Operating Temperature: 

-20

°

C to 70

°

C.

Size: 

104mm x 72mm x 27mm. 

Weight: 

150gms. 

APP SPECIFICATIONS 

iOS: 

Compatible with iPhone 4S and later with iOS 7 and higher. 

Android: 

Compatible with most Android-supported phones from 2013 and later 
with Android 4.4 or higher. 

CONNECTIONS 

PINS 1 & 2

 

Power supply input, not polarity conscious. 
(Red & Black wires). 

PINS 3 & 4

 

Normally Open relay output. 
(White & Yellow wires). 

Note  that  the  supplied  wires  in  the  connector  can  be 
replaced  by  using  a  small  screwdriver  to  depress  the 
orange tab, this will release the wire in the connector and 
a new wire can be inserted whilst the orange tab is being 
depressed.  The new wire requires 8mm of the insulation 
to be stripped before being inserted. 

INSTALLATION REQUIREMENTS 

1.

Install  the  unit  in  a  location  where  it  will  be  shielded  from  moisture,  direct
sunlight and pests.

2.

When installing the unit inside a metal box an externally mounted antenna is
required.  If installing outdoors it is preferable to install it in a water proof plastic
container.

3.

The power supply to the unit should be stable and secure.

4.

Do not install a unit with external damage.

5.

Installation  should  be  performed  by  a  trained  and  licensed  installation
professional.

INSTALLATION OF THE GATE UNIT 

1.

Remove the unit from the packaging and make sure it is physically intact.

2.

Attach the antenna to the OmGate unit.

3.

Connect 2 cables (white and yellow) to the door or gate's opening mechanism.

4.

Connect 2 cables (black and red) to the power supply.

5.

Ensure that the unit is functional (see Indicator Lights below).

INDICATOR LIGHTS 

Fixed blue light 

Indicates proper input voltage. 

Red light 

Indicates relay operation (also flashes on power up). 

Lights off 

Unit has no power or is damaged. 

As the default setting, Omgate allows for up to 10 free concurrent Users. An online 

payment system, directly from the App, allows administrators the ability to purchase 

licenses for 20, 50, 100 & 500 Users.