RhinoBond Owner’s Manual

  Page 7

 AUTOMATIC CALIBRATION 

The new RhinoBond Tool features “OptiWeld” automatic calibration for optimum welding.  

    

When set in OptiWeld mode, the “Mode” button displays OptiWeld. Membrane type and thickness and fine adjust set-tings 

are also displayed. Pressing the “Mode” button allows users to toggle between “OptiWeld” and “Manual” operating mode. 

 

Pressing the “Membrane” button allows users to adjust the “OptiWeld” settings.

 

From the “Device Ready” screen, press the “Membrane” button and select the type (TPO or PVC) and thickness 

(45, 60, 80 mil) of the membrane you are installing. 
Press “Save” to return to the “Device Ready” screen. 

 

 

Activations Log:

  The “Activation Today” button displays the number of weld cycles performed on that calendar 

day. Pressing this button will open the tool log, where a history of weld cycles can be reviewed.  

 

Power Display:

  The Power Display shows the line voltage the tool is receiving from the power source. 

The tool requires a minimum of 100 volts to operate effectively. 

 

            

Menu:

  Pressing this button will open the menu screen.

 

 

Once the tool settings are complete and accurate for the membrane type and thickness being installed, the tool is ready 

to weld.
To activate the tool, place the tool over the plate by aligning the target area on the base of the tool directly over the 

plate to be welded. The tool should be centered over the RhinoBond plate for an optimum weld.   

 

When the tool is aligned over the plate, press the activation button, also called the trigger, located on the handle of 

the tool.   

 

The display will indicate the tool is in activation mode and show a progress bar. 

 

When the weld is complete, the RhinoBond tool will emit a beep, provided that the sound is turned on  

(see Page 11), and display the “Activation Done” screen.  

 

The screen will automatically return to the “Device Ready” screen for the next weld.

Содержание RBT007

Страница 1: ...v 06252020 153 BOWLES ROAD AGAWAM MA 01001 USA 800 633 3800 413 789 0252 RHINOBOND COM Non penetrating fastening system for commercial roofing IMPORTANT Save this manual and read it in full before use...

Страница 2: ...le easy to use system that secures membrane to roofing substrates using micropro cessor controlled induction welding Roofing installed this way has several benefits Fewer Fasteners RhinoBond requires...

Страница 3: ...conditions Keep the tool dry at all times ALWAYS ENSURE that the tool is properly grounded CFCI Circuits are best and that power is from a safe and reliable source ALWAYS WEAR proper personal protecti...

Страница 4: ...z 220V 50Hz EXTENSION CORD 12 gauge min 100 ft max 110V 2 5mm X 30m 16A 230V 3x15 30m 10A 30m PORTABLE GENERATOR POWER SOURCE 5 000W min with 2 20A GFCI Circuits 2 5 KVA min with 16Amp 110V protected...

Страница 5: ...s under each plate to protect the insulation from melting On foil faced insulation the recommended minimum cover board is 1 in 38 mm Metal Deck A minimum of 1 inches 38 mm of insulation over a metal d...

Страница 6: ...progress If necessary you can calibrate the touch screen at this time To do so touch this screen once to begin the calibration process see below Once startup is complete the screen will display the L...

Страница 7: ...es can be reviewed Power Display The Power Display shows the line voltage the tool is receiving from the power source The tool requires a minimum of 100 volts to operate effectively Menu Pressing this...

Страница 8: ...ce of membrane from the project weld each plate and apply a magnetic heat sink to each Allow plates to cool to the touch approx 5 minutes before removing the magnetic heat sinks Turn the membrane over...

Страница 9: ...gy Level setting push the plus or minus buttons Push the Home button once the energy setting is set The screen will automatically return to the Device Ready screen The Device Ready screen will display...

Страница 10: ...gnetic cooling clamp on the plate and mark the energy setting on the membrane for reference Adjust the Energy Level to the next higher setting and repeat the test weld process until all five plates ar...

Страница 11: ...arrow to return to the previous screen Press the Sound button to change the Activation Complete tone The sound can be enabled by press ing the On button and disabled by pressing the Off button You ha...

Страница 12: ...t factory reset Press the Home button to return to the Device Ready screen Press the back arrow to return to the previous screen From the main Menu press the Help button to access OMG Roofing Products...

Страница 13: ...main Menu press the Help button to review the Troubleshooting tips and error message descriptions Press any of the error message buttons to get more information and recommendations Press the back arro...

Страница 14: ...Voltage Directive LVD 2006 95 EC The following harmonized standards were applied LVD EN60335 1 2012 A11 2014 EN60335 2 45 2002 A2 2012 RhinoBond Induction Welding Tools wielding the CE Mark comply wi...

Страница 15: ...RhinoBond Owner s Manual Page 15 NOTES...

Страница 16: ...OMG Roofing Products 153 Bowles Road Agawam MA 01001 USA 800 633 3800 413 789 0252 www rhinobond com...

Отзывы: